Hostname: page-component-74656f9884-npj9w Total loading time: 0 Render date: 2026-11-06T23:43:40.292Z Has data issue: false hasContentIssue false

Measurement of cerebral perfusion with arterial spin labeling: Part 2. Applications

Published online by Cambridge University Press:  20 March 2007

GREGORY G. BROWN
Affiliation:
Psychology Service, VA San Diego Healthcare System, San Diego, California Department of Psychiatry, University of California San Diego, San Diego, California
CAMELLIA CLARK
Affiliation:
Department of Psychiatry, University of California San Diego, San Diego, California
THOMAS T. LIU
Affiliation:
Department of Radiology, University of California San Diego, San Diego, California
Rights & Permissions [Opens in a new window]

Abstract

Arterial spin labeling (ASL) uses magnetic resonance imaging methods to measure cerebral blood flow (CBF) non-invasively. ASL CBF validly localizes brain function and may be especially useful for studies where the time frame of behavioral change is more than a few minutes, such as in longitudinal and treatment studies. ASL measures of cerebral perfusion are highly accurate in detecting lesion laterality in temporal lobe epilepsy, stenotic-occlusive disease, and brain tumors. Among lesioned patients, ASL CBF has excellent concurrent validity when correlated with CBF measured by Positron Emission Tomography or with dynamic susceptibility-weighted magnetic resonance. ASL CBF can predict tumor grading in vivo and can predict six-month response to the surgical treatment of brain tumors. ASL's capability to selectively and non-invasively tag flow in major vessels may refine the monitoring of treatment of cerebrovascular disease and brain tumors. Conclusions about the utility of ASL are limited by the small sample sizes of the studies currently in the literature and by the uncertainty caused by the effect of brain disease on transit times of the magnetic tag. As the method evolves, ASL techniques will likely become more widely used in clinical research and practice. (JINS, 2007, 13, 526–538.)

Information

Type
CRITICAL REVIEW
Copyright
© 2007 The International Neuropsychological Society
Figure 0

Perfusion images from a FAIR sequence. Voxels were resliced into 1 mm3 and smoothed by an amount of 3.44 mm full width half maximum, the original in-plane pixel length. A threshold was set to emphasize cortical flow.

Figure 1

Arterial spin labeling findings during behavioral challenge

Figure 2

Arterial spin labeling findings in patients with cerebrovascular disease

Figure 3

Arterial spin labeling findings in patients with brain tumors