Hostname: page-component-74656f9884-2dmjx Total loading time: 0 Render date: 2026-11-07T05:35:53.851Z Has data issue: false hasContentIssue false

The Kiwi hoop for Boyle–Davies gag suspension during tonsillectomy

Published online by Cambridge University Press:  29 September 2009

F Ahsan*
Affiliation:
Department of Otolaryngology Head and Neck Surgery, Christchurch Hospital, New Zealand
S Stevenson
Affiliation:
Department of Otolaryngology Head and Neck Surgery, Christchurch Hospital, New Zealand
*
Address for correspondence: Mr Syed Farhan Ahsan, Clinical Fellow, Head and Neck Surgery, Department of Otolaryngology Head and Neck Surgery, Christchurch Hospital, Riccarton Avenue, Private Bag 4710, Christchurch, New Zealand. E-mail: farhan099@hotmail.com
Rights & Permissions [Opens in a new window]

Abstract

We describe an alternative method of suspending the Boyle–Davis gag during tonsillectomy. Use of the traditional Draffin's bipod for positioning patients during tonsillectomy is associated with a number of difficulties. These include limited height adjustment and problems with slipping during operation. We describe an alternative arrangement for suspension of the Boyle-Davis gag. This arrangement has been successfully used for many years, and offers advantages because of its stability and adjustability.

Information

Type
Short Communications
Copyright
Copyright © JLO (1984) Limited 2009
Figure 0

Fig. 1 The Kiwi hoop.

Figure 1

Fig. 2 The Kiwi hoop being positioned (adjustable in the vertical plane).

Figure 2

Fig. 3 The Kiwi hoop and Boyle–Davis gag apparatus in position on a patient.