Hostname: page-component-74656f9884-6grmk Total loading time: 0 Render date: 2026-11-06T07:20:44.498Z Has data issue: false hasContentIssue false

Strong electromagnetic pulses generated in high-intensity short-pulse laser interactions with thin foil targets

Published online by Cambridge University Press:  02 November 2017

P. Rączka*
Affiliation:
Institute of Plasma Physics and Laser Microfusion, Warsaw, Poland
J.-L. Dubois
Affiliation:
CELIA, University of Bordeaux-CNRS-CEA, Talence, France
S. Hulin
Affiliation:
CELIA, University of Bordeaux-CNRS-CEA, Talence, France
V. Tikhonchuk
Affiliation:
CELIA, University of Bordeaux-CNRS-CEA, Talence, France
M. Rosiński
Affiliation:
Institute of Plasma Physics and Laser Microfusion, Warsaw, Poland
A. Zaraś-Szydłowska
Affiliation:
Institute of Plasma Physics and Laser Microfusion, Warsaw, Poland
J. Badziak
Affiliation:
Institute of Plasma Physics and Laser Microfusion, Warsaw, Poland
*
Address correspondence and reprint requests to: P. Rączka, Division of Laser Plasma, Institute of Plasma Physics and Laser Microfusion, ul. Hery 23, 01-497 Warsaw, Poland. E-mail: piotr.raczka@ifpilm.pl

Abstract

Measurements are reported of the target neutralization current, the target charge, and the tangential component of the magnetic field generated as a result of laser–target interaction by pulses with the energy in the range of 45–92 mJ on target and the pulse duration from 39 to 1000 fs. The experiment was performed at the Eclipse facility in CELIA, Bordeaux. The aim of the experiment was to extend investigations performed for the thick (mm scale) targets to the case of thin (μm thickness) targets in a way that would allow for a straightforward comparison of the results. We found that thin foil targets tend to generate 20–50% higher neutralization current and the target charge than the thick targets. The measurement of the tangential component of the magnetic field had shown that the initial spike is dominated by the 1 ns pulse consistent with the 1 ns pulse of the neutralization current, but there are some differences between targets of different types on sub-ns scale, which is an effect going beyond a simple picture of the target acting as an antenna. The sub-ns structure appears to be reproducible to surprising degree. We found that there is in general a linear correlation between the maximum value of the magnetic field and the maximum neutralization current, which supports the target-antenna picture, except for pulses 100s of fs long.

Information

Type
Research Article
Copyright
Copyright © Cambridge University Press 2017 
Figure 0

Fig. 1. A 1 mm thick and 10 mm in diameter Cu “pill” with 1 mm holes in which very thin foils could be pasted, allowing for a straightforward comparison of the EMP generated from a 1 mm thick Cu target and a 6 µm thin Al foil.

Figure 1

Fig. 2. A schematic view of the experimental chamber, with the indicated location of the B-dot probes.

Figure 2

Fig. 3. The target neutralization current as a function of time for three shots at different types of targets, representative of a bigger sample.

Figure 3

Fig. 4. The target charge as a function of time, as obtained by integrating the time-dependent neutralization current, for three shots representative of a larger sample.

Figure 4

Fig. 5. The target charge as a function of the laser pulse energy on target, for the pulse duration close to 40 fs. For parameters where three or more consistent data points were obtained, the averages are shown with error bars. The points indicated as “Cu frame” correspond to the shot on the massive Cu frame of a target containing AlPs foil. The dashed line represents a linear fit to the data for the thick Cu target, with the intercept constrained to 0.

Figure 5

Fig. 6. The target charge as a function of the pulse duration, for the pulse energy close to 90 mJ. The “Cu frame” points indicate shots on the thick Cu frame supporting the AlPs foil.

Figure 6

Fig. 7. The maximum value of the target neutralization current as a function of the pulse energy, for the pulse duration close to 40 fs. The dashed line represents a linear fit to the data for the thick Cu target, with the intercept constrained to 0.

Figure 7

Fig. 8. The maximum value of the target neutralization current as a function of the pulse duration, for the pulse energy close to 90 mJ.

Figure 8

Fig. 9. The tangential component of the magnetic field as a function of time, as measured by the B-dot1 for three shots representative of broader sample.

Figure 9

Fig. 10. The structure of the initial spikes shown on a short time scale for the three shots representative of a broader sample.

Figure 10

Fig. 11. The short time-scale structure of the initial spike, as revealed by the behavior of the dB/dt for the three shots representative of a broader sample. The differences between signal from different types of targets is to be noted.

Figure 11

Fig. 12. The short time-scale structure of the initial spike, as revealed by the behavior of the dB/dt for the shots at two different targets with pulses of 500 fs duration. The B-dot2 signal was shifted in time so that the initial spikes would coincide in time.

Figure 12

Fig. 13. Comparison of the magnetic field measurements by the B-dot1 and B-dot2 for the shot 109 on a thin AlPs target.

Figure 13

Fig. 14. The one-sided discret FT spectrum of the tangential component of the magnetic field, as obtained from the B-dot1 probe, for three shots representative of a broader sample.

Figure 14

Fig. 15. The maximum values of Btg for shots of approximate duration 40 fs, performed at various energies.

Figure 15

Fig. 16. The correlation plot between the maximum value of Btg in the spike and the maximum value of the neutralization current in the given shot, for the sample of shots shown in Figure 15.

Figure 16

Fig. 17. The maximum values of Btg for shots performed at the energy close to 90 mJ and different pulse durations.

Figure 17

Fig. 18. The correlation plot between the maximum value of Btg in the spike and the maximum value of the neutralization current in the given shot, for the sample of shots shown in Figure 17.