Hostname: page-component-74656f9884-rdgjk Total loading time: 0 Render date: 2026-11-07T05:45:54.788Z Has data issue: false hasContentIssue false

Use of the advisor™ HD Grid mapping catheter in transcatheter ablation of atrial arrhythmias in palliated CHD and children without CHD

Published online by Cambridge University Press:  12 October 2023

Şevket Balli*
Affiliation:
Department of Pediatric Cardiology, Dr. Siyami Ersek Thoracic and Cardiovascular Surgery Training & Research Hospital, University of Health Sciences, İstanbul, Turkey
Pınar Kanlioğlu
Affiliation:
Department of Pediatric Cardiology, Dr. Siyami Ersek Thoracic and Cardiovascular Surgery Training & Research Hospital, University of Health Sciences, İstanbul, Turkey
Hüsnü F. Altin
Affiliation:
Department of Pediatric Cardiovascular Surgery, Dr. Siyami Ersek Thoracic and Cardiovascular Surgery Training & Research Hospital, University of Health Sciences, İstanbul, Turkey
*
Corresponding author: Ş. Balli; Email: drsevketballi@hotmail.com
Rights & Permissions [Opens in a new window]

Abstract

Objective:

In this study, we describe our experience utilising Advisor™ High Density (HD) Grid mapping catheter in transcatheter ablation of intraatrial re-entrant and focal atrial tachycardias with or without CHD.

Methods:

Forty-five consecutive patients with intraatrial re-entrant and focal atrial tachycardia who underwent a transcatheter ablation procedure by using Advisor™ HD Grid mapping catheter and high-density mapping system in our hospital from January 2017 to January 2023 were included into the study.

Results:

The mean age of the patients was 14.2 ± 7.3 years (6–32 years), and the mean weight was 48.3 ± 16.2 kg (22–83 kg). Of the total 45 patients, 21 were intraatrial re-entrant tachycardia and 25 were focal atrial tachycardia. Of the 21 re-entrant circuits, 15 were classified as cavotricuspid isthmus-dependent and 5 were non-cavotricuspid isthmus-dependent. In one patient, two re-entrant circuits were identified. A transbaffle ablation was successfully performed from the left atrium in one patient. Of the 25 focal atrial tachycardia, 19 were from right atrium and 6 were from left atrium. A cryoablation was performed in only one patient and radiofrequency ablation in others. The mean procedure time was 180 ± 64 minutes. The mean follow-up period was 69.3 ± 35.3 months. Acute success was 95.5%. Recurrence was noted in two patients (4.4%).

Conclusion:

Advisor™ HD Grid mapping catheter was found to be safe and achieved an acceptable success in transcatheter ablation of patients with intraatrial re-entrant tachycardia and focal atrial tachycardias.

Information

Type
Original Article
Copyright
© The Author(s), 2023. Published by Cambridge University Press
Figure 0

Table 1. Patients characteristics

Figure 1

Table 2. Procedural data

Figure 2

Figure 1. Advisor™ HD grid catheter was shown.

Figure 3

Figure 2. Advisor™ HD grid catheterised mapping of a patient with intraatrial re-entrant tachycardia originating from the right atrial scar area. Scar areas and isthmus were observed. Diagram of the tachycardia location was shown.