Hostname: page-component-74656f9884-8r8nv Total loading time: 0 Render date: 2026-11-08T07:58:01.172Z Has data issue: false hasContentIssue false

Effect of cleaning procedure and hygienic condition of milking equipment on bacterial count of bulk tank milk

Published online by Cambridge University Press:  04 March 2011

Luciana Bava*
Affiliation:
Dipartimento di Scienze Animali, Università degli Studi di Milano, via Celoria 2, 20133 Milano, Italy
Maddalena Zucali
Affiliation:
Dipartimento di Scienze Animali, Università degli Studi di Milano, via Celoria 2, 20133 Milano, Italy
Anna Sandrucci
Affiliation:
Dipartimento di Scienze Animali, Università degli Studi di Milano, via Celoria 2, 20133 Milano, Italy
Milena Brasca
Affiliation:
Istituto di Scienze delle Produzioni Alimentari, CNR, via Celoria 2, 20133 Milano, Italy
Laura Vanoni
Affiliation:
Istituto di Scienze delle Produzioni Alimentari, CNR, via Celoria 2, 20133 Milano, Italy
Lucio Zanini
Affiliation:
Associazione Regionale Allevatori della Lombardia, viale Kennedy 30, 26013 Crema, Italy
Alberto Tamburini
Affiliation:
Dipartimento di Scienze Animali, Università degli Studi di Milano, via Celoria 2, 20133 Milano, Italy
*
*For correspondence: luciana.bava@unimi.it
Rights & Permissions [Opens in a new window]

Abstract

The aim of the study was to describe the characteristics of cleaning procedures for milking equipment applied in intensive dairy farms in Lombardy (Italy) and to study their relationships with bacterial count of bulk milk and hygienic condition of milking machine components. A group of 22 dairy farms was visited twice (winter and summer) in order to collect bulk tank milk and post-rinse water samples and swabs from liners and milk receiver. Samples were analysed to determine: standard plate count (SPC), laboratory pasteurization count (LPC), psychrotrophic bacteria count (PBC), coliform count (CC) and Escherichia coli. Cleaning procedures were monitored using electronic milk flow meters with specific software for the measurement of the duration of each cleaning phase, circulating solution temperature and electrical conductivity, turbulence and water filling percentage of pipelines. The results showed that farms classified as high and low milk total bacteria count significantly differed both in terms of liners and receiver bacterial contamination and in terms of water temperature reached during the detergent phase of cleaning milking equipment. Significant positive correlations were found among total bacteria count in milk and bacterial contamination of the liners. Maximum water temperature reached during the cleaning cycle of milking equipment was very low (34·4±8·9°C on average); most of the observations (88·6%) corresponded to water temperatures <45°C. Cleaning temperature was related to psychrotrophic bacteria count of milk and post-rinse water and coliform count in liners. Routine check and regulation of water temperature during the washing phase of the milking machine can be a simple and effective way to control one of the main risk factors for bacteriological quality of bulk tank milk.

Information

Type
Research Article
Copyright
Copyright © Proprietors of Journal of Dairy Research 2011
Figure 0

Table 1 Characteristics of the 22 dairy farms classified on the basis of milk standard plate count (LSPC, low standard plate count; HSPC, high standard plate count) of the previous 3 years

Figure 1

Table 2 Bacterial counts† of milk and post-rinse water, receiver and liner swabs and characteristics of detergent phase during cleaning cycle of milking equipment of farms classified high (HSPC) or low (LSPC) standard plate count. Values are least squares means

Figure 2

Fig. 1. Frequency distribution of maximum water temperatures (T) during the detergent phase of milking equipment cleaning cycles (▪ maximum water T <35°C; maximum water T ⩾35°C).

Figure 3

Table 3 Effect of maximum water temperature (°C) during the detergent phase on bacterial count† of milk and post-rinse water, receiver and liner swabs. Values are least squares means

Figure 4

Fig. 2. Relationships between coefficients of variation (CV) and means of all observations for turbulence (y=−0·52x +52·03; r2=0·476) and percentage of water filling (y=−1·22x +60·98; r2=0·314).

Figure 5

Fig. 3. Relationship between electrical conductivity of the detergent solution (measured by Lactocorder) and detergent concentration ▪: concentration of detergent determined by calibration curves; ◊: concentration of detergent declared by farmers; linear - - - - - (concentration of detergent determined by calibration curves; y=0·206x − 0·227; r2=0·667); linear — (concentration of detergent declared by farmers; y=0·159x +0·577; r2=0·126).

Figure 6

Table 4 Correlation coefficients between bacterial count† of bulk tank milk and bacterial count of liner swabs

Figure 7

Fig. 4. Canonical discriminant analysis for type of cleaning procedure and problems. ▪: HSPC (high standard plate count) farm observations; : LSPC (low standard plate count) farm observations; : mean value for ‘good cleaning procedures’ group; : mean value for ‘conductivity and temperature failure’; X: mean value for ‘temperature failure’.