Hostname: page-component-7b7567c8c-fvjsw Total loading time: 0 Render date: 2026-11-12T07:02:29.487Z Has data issue: false hasContentIssue false

Unconventional deployment of atrial septal occluder in a patient with atrial septal defect, dextrocardia, and interrupted inferior vena cava

Published online by Cambridge University Press:  29 June 2020

Sreekanth Yerram*
Affiliation:
Department of Cardiology, Nizam’s Institute of Medical Sciences, Hyderabad, India
Sunitha Aramalla
Affiliation:
Department of Cardiology, Nizam’s Institute of Medical Sciences, Hyderabad, India
Srinivas Bhyravavajhala
Affiliation:
Department of Cardiology, Nizam’s Institute of Medical Sciences, Hyderabad, India
*
Author for correspondence: Sreekanth Yerram, MD, DM, Nizam’s Institute of Medical Sciences, Panjagutta, 500082Hyderabad, India. Tel: +91 9490879029. E-mail: sreeyerram@gmail.com
Rights & Permissions [Opens in a new window]

Abstract

An atrial septal defect is a rare anomaly in patients with interrupted inferior vena cava, which renders the percutaneous intervention more complex; and hence, innovative approaches should be sought. Dextrocardia further complicates the procedure, and traditional atrial septal device deployment methods cannot be employed. We report a successful percutaneous secundum atrial septal defect closure by a novel deployment strategy along with balloon dilation of associated severe valvular pulmonary stenosis in a patient with dextrocardia and interrupted inferior vena cava.

Information

Type
Brief Report
Copyright
© The Author(s), 2020. Published by Cambridge University Press
Figure 0

Figure 1.(a) Transthoracic echocardiography with color Doppler in the parasternal short-axis view illustrating the atrial septal defect with left to right shunt (the probe has been inverted to get the normal anatomical orientation). (b) Angiogram of the inferior vena cava in the lateral view showing the inferior vena cava continuing as azygus vein and joining the superior vena cava.

Figure 1

Figure 2.(a) Lunderquist wire along with the sheath being placed in the left ventricular apex from the left internal jugular vein in anteroposterior view on fluoroscopy. (b) Transthoracic echo showing the device being deployed in the left ventricular inflow across the mitral valve leaflets to align the device. (The echo view has been inverted at the time of acquisition for better understanding.)

Figure 2

Figure 3.(a) Fluoroscopy in the left anterior oblique view showing the device fully deployed with a good waist of the device. (b) Fluoroscopy in the lateral view depicting the balloon pulmonary valvuloplasty.

Figure 3

Figure 4.Transthoracic echo with colour Doppler study showing the atrial septal occluder in position without any residual shunt (echo images acquired with the probe inverted).

Yerram et al. supplementary material

Yerram et al. supplementary material

Download Yerram et al. supplementary material(Video)
Video 4.6 MB