Introduction
Ankyrin-B syndrome, linked to variants in ANK2, is classified as long QT syndrome type 4 and is characterised by a broad spectrum of cardiac arrhythmias.Reference Ackerman and Mohler1–Reference Mohler, Splawski and Napolitano3 Unlike the more common forms of congenital long QT syndrome, which primarily affect ion channel subunits, ankyrin-B dysfunction disrupts the intracellular targeting, and stability of multiple ion transporters.Reference Mohler, Le Scouarnec and Denjoy2 As a result, affected individuals may present with heterogeneous electrical phenotypes, including QT prolongation, atrial arrhythmias, sinus node dysfunction, and variable conduction disturbances.Reference Musa, Murphy and Curran4
Although conduction system involvement has been described in experimental models and clinical series, clinically significant atrioventricular block requiring permanent pacing in paediatric patients remains uncommon.Reference Mohler, Le Scouarnec and Denjoy2,Reference Mohler, Splawski and Napolitano3 The mechanisms underlying atrioventricular nodal dysfunction in ankyrin-B–related disease are not fully understood but are thought to reflect altered membrane protein localisation within specialised conduction tissue.Reference Cunha, Hund and Hashemi5
Management of high-degree atrioventricular block in children poses additional challenges, particularly in the context of inherited arrhythmic disorders.Reference Shah, Silka and Silva6 Decisions regarding permanent pacing must consider growth, long-term device complications, and the potential need for future defibrillator therapy.Reference Shah, Borquez and Cortez7,Reference Olde Nordkamp, Wilde, Tijssen, Knops, van Dessel and de Groot8
We report a child with an ANK2 variant and long QT phenotype who developed persistent high-degree atrioventricular block requiring implantation of a leadless pacemaker. This case highlights clinically significant conduction disease in a child harbouring an ANK2 variant and underscores the importance of careful rhythm surveillance and individualised management in affected families.
Case description
A 10-year-old boy was admitted following two episodes of transient loss of consciousness accompanied by seizure-like activity. On the morning of presentation, he experienced dizziness and pallor while playing, which transiently improved with rest. Later that day, he suddenly collapsed while using a mobile phone. The first episode lasted approximately 10 s and was described as tonic–clonic in nature with loss of consciousness. A second brief episode occurred shortly thereafter. Emergency medical services transported him to the emergency department for evaluation.
He had been diagnosed with long QT syndrome three months earlier after evaluation for recurrent dizziness. Baseline electrocardiography at the time of diagnosis demonstrated QT prolongation with a corrected QT interval (QTc) of 462 ms (Figure 1 a ). During epinephrine provocation testing, tangential-method measurement showed a QTc of 550 ms in lead II and 526 ms in lead V5 (Figure 1 b ). Nadolol therapy was initiated and titrated to 40 mg daily, but subsequently reduced to 30 mg due to persistent dizziness.
Twelve-lead electrocardiograms of the proband. ( a ) Baseline ECG at initial diagnosis demonstrating QT prolongation (QTc 462 ms). ( b ) ECG obtained during epinephrine provocation testing showing QT prolongation, with a QTc of 550 ms in lead II and 526 ms in lead V5 by tangential-method measurement. ( c ) High-degree atrioventricular block with non-conducted P waves and associated ventricular pauses while receiving nadolol therapy. ( d ) Persistent high-degree atrioventricular block observed after discontinuation of nadolol, supporting intrinsic conduction system involvement.

Figure 1. Long description
Panel A: A twelve-lead electrocardiogram at initial diagnosis showing QT prolongation with a QTc of 462 milliseconds. The graph displays multiple leads, including aVR, aVL, aVF, V1 to V6, and limb leads. The horizontal axis represents time, and the vertical axis represents electrical activity. The QT interval is prolonged across all leads. Panel B: A twelve-lead electrocardiogram obtained during epinephrine provocation testing showing further QT prolongation with a QTc of 550 milliseconds in lead II and 526 milliseconds in lead V5. The graph displays similar leads as Panel A, with prolonged QT intervals visible. Panel C: A twelve-lead electrocardiogram showing high-degree atrioventricular block with non-conducted P waves and associated ventricular pauses while the patient is receiving nadolol therapy. The graph shows clear instances of blocked atrial signals and subsequent ventricular pauses. Panel D: A twelve-lead electrocardiogram showing persistent high-degree atrioventricular block after discontinuation of nadolol, indicating intrinsic conduction system involvement. The graph displays similar leads as previous panels, with persistent blockages and pauses.
Family history was notable for sudden cardiac death in a sister at 12 years of age. Available autopsy/forensic documentation showed no toxicologic abnormality or major traumatic injury and described cardiomegaly, a single coronary artery, and an intramuscular coronary artery course; the cause of death was adjudicated as sudden cardiac death due to cardiac pathology. Targeted sequencing of an inherited arrhythmia gene panel identified a heterozygous ANK2 variant of uncertain significance (NM_001148.4:c.5626G>A, p. Glu1876Lys; rs1554553071). The same variant was identified in the patient’s mother and brother, whereas the father tested negative. The mother showed sinus bradycardia without marked QT prolongation on available ECG. The brother showed borderline QT prolongation on ECG and ventricular ectopy, including a ventricular couplet, on Holter monitoring. A childhood ECG from the deceased sister did not show definite QT prolongation, but her genotype was unavailable. Pedigree is provided in Figure 2, and representative ECG findings of family members are provided in the Supplementary Materials.
Pedigree of the family. The proband is indicated by the arrow. The proband, mother, and brother carried the same heterozygous ANK2 variant, whereas the father tested negative. Genetic testing was unavailable in the deceased sister, who died suddenly at 12 years of age.

On admission, continuous telemetry monitoring demonstrated frequent episodes of high-degree atrioventricular block with ventricular pauses while the patient was receiving nadolol therapy (Figure 1 c ). Given the concern for bradycardia-related syncope, a temporary pacemaker was inserted. Nadolol was subsequently discontinued to evaluate the possibility of drug-related conduction suppression; however, repeat telemetry continued to show high-degree atrioventricular block in the absence of beta-blockade (Figure 1 d ), supporting intrinsic conduction system involvement.
Given the recurrent symptomatic conduction disturbance and the underlying inherited arrhythmic substrate, permanent pacing was recommended. Considering the patient’s age, long-term lead-related complications, and anticipated somatic growth, a leadless pacemaker system (Micra MRI AV, Medtronic, Minneapolis, MN, USA) was selected. The device was successfully implanted via femoral venous access (27 Fr sheath) without procedural complications (Supplementary Figure 2). At the time of Micra AV implantation, the patient was 137.1 cm tall, weighed 44.9 kg, and had a body surface area of 1.31 m2.
Post-implant device interrogation demonstrated satisfactory electrical parameters, including ventricular sensing amplitude of 11.7 mV, pacing threshold of 1.63 V at 0.4 ms, and impedance of 540 Ω. Follow-up echocardiography confirmed appropriate device position without evidence of valvular injury or pericardial effusion. The patient has remained free of recurrent syncope or ventricular arrhythmia during follow-up.
Discussion
Ankyrin-B syndrome, associated with variants in ANK2, is recognised as a rare and heterogeneous form of inherited arrhythmia, historically classified as long QT syndrome type 4.Reference Ackerman and Mohler1,Reference Mohler, Splawski and Napolitano3 Unlike the more prevalent channelopathies involving ion channel pore-forming subunits, ankyrin-B dysfunction disrupts intracellular trafficking and membrane localisation of multiple ion transporters, resulting in diverse electrical phenotypes.Reference Mohler, Le Scouarnec and Denjoy2,Reference Cunha, Hund and Hashemi5 Clinical manifestations may include sinus node dysfunction, atrial arrhythmias, ventricular arrhythmias, and conduction disturbances in addition to QT prolongation.Reference Mohler, Le Scouarnec and Denjoy2,Reference Musa, Murphy and Curran4
In the present case, the proband demonstrated marked QT prolongation during epinephrine provocation testing, together with persistent high-degree atrioventricular block. Although bradyarrhythmias and conduction abnormalities have been described in ankyrin-B–related disease, reports of high-degree atrioventricular block requiring permanent pacing in children harbouring an ANK2 variant are limited.Reference Mohler, Le Scouarnec and Denjoy2,Reference Mohler, Splawski and Napolitano3 The observed conduction disturbance persisted despite withdrawal of beta-blocker therapy, suggesting intrinsic conduction system involvement rather than medication-related suppression.
The underlying mechanism of conduction disease in ankyrin-B syndrome is not fully elucidated but is thought to reflect impaired membrane targeting of key ion transporters within specialised conduction tissue.Reference Mohler, Le Scouarnec and Denjoy2 Experimental models have demonstrated altered calcium handling and sodium channel regulation associated with ankyrin-B deficiency, which may predispose to both bradyarrhythmic and tachyarrhythmic events.Reference Mohler, Le Scouarnec and Denjoy2,Reference Koenig and Mohler9 The coexistence of QT prolongation and atrioventricular block in this patient may suggest pleiotropic electrical effects potentially attributable to ANK2 dysfunction, though causality cannot be established given the VUS classification of the identified variant.Reference Ackerman and Mohler1,Reference Robaei, Ford and Ooi10
Genetic testing identified a heterozygous ANK2 variant classified as a VUS. Family testing showed maternal transmission, with the same variant detected in the mother and brother and absent in the father. However, the phenotype among variant carriers was variable, and the deceased sister was not genotyped. Moreover, available autopsy findings in the sister documented structural cardiac abnormalities. Therefore, although the family data provide important phenotypic context, they do not establish pathogenicity of the ANK2 variant. This case underscores the complexity of variant interpretation in inherited arrhythmia syndromes and the importance of integrating genotype with detailed family phenotyping.Reference Walsh, Thomson and Ware11,Reference Lubitz and Ellinor12
Because the identified ANK2 variant remains a VUS, alternative causes of atrioventricular block were also considered. Structural heart disease was not identified on echocardiography. Coronary CT angiography was not performed. Although maternal rheumatoid factor testing was negative, SSA antibody testing was unavailable; therefore, autoimmune-mediated atrioventricular conduction disease could not be completely excluded. However, in the absence of a reversible metabolic or drug-related cause and with persistence of high-degree atrioventricular block after nadolol withdrawal, intrinsic conduction system disease was considered the most likely explanation in this case.
Management of high-degree atrioventricular block in children with inherited arrhythmic disorders presents unique challenges. Permanent pacing strategies must balance immediate symptom control with long-term considerations, including somatic growth, preservation of venous access, device longevity, and the potential future need for implantable cardioverter-defibrillator therapy.Reference Shah, Silka and Silva6 In this patient, a leadless pacemaker system was selected to minimise transvenous lead-related complications and vascular burden. The device was successfully implanted, and electrical performance parameters remained stable during follow-up. Because the device currently serves primarily as backup pacing, the ventricular pacing burden remains extremely low (<0.1%), suggesting a low current risk of pacemaker-induced cardiomyopathy. Nadolol was resumed because of the marked QT prolongation observed during epinephrine provocation testing. Although the pacemaker provides backup protection against bradycardia, the patient was advised to avoid competitive sports and strenuous exercise, with continued follow-up for reassessment of repolarisation-related arrhythmic risk. Long-term follow-up should include serial device interrogation, echocardiographic surveillance for pacing-related ventricular dysfunction, continued surveillance for evolving sinus node dysfunction, and individualised planning regarding future device retrieval or additional implantation at battery depletion.
Although leadless pacing in paediatric populations remains relatively limited, emerging data suggest favourable short- and mid-term outcomes.Reference Shah, Borquez and Cortez7 However, long-term experience, extraction feasibility, and implications for future device therapy require continued surveillance.
This case illustrates clinically significant conduction disease in a child with the identification of an ANK2 variant and demonstrates the feasibility of leadless pacing in this context. Careful rhythm monitoring and individualised management strategies are essential in families with inherited arrhythmia syndromes exhibiting variable phenotypic expression.
Supplementary material
The supplementary material for this article can be found at https://doi.org/10.1017/S1047951126123464.
Acknowledgements
The English language quality of this manuscript was enhanced with the assistance of OpenAI’s ChatGPT.
Author contributions
The author was responsible for all aspects of the manuscript.
Financial support
Jihye You is supported by the Fund of the Biomedical Research Institute, Jeonbuk National University Hospital.
Competing interests
The author declares no conflicts of interest in preparing this article.
Ethical standard
The Institutional Review Board of Jeonbuk National University Hospital approved this study (IRB No. 2024-06-041).