Hostname: page-component-74656f9884-npj9w Total loading time: 0 Render date: 2026-11-09T22:25:35.181Z Has data issue: false hasContentIssue false

Estimates of the refreezing rate in an ice-shelf borehole

Published online by Cambridge University Press:  10 July 2017

Kenneth G. Hughes
Affiliation:
Department of Physics, University of Otago, Dunedin, New Zealand E-mail: kenneth.hughes@otago.ac.nz
Pat J. Langhorne
Affiliation:
Department of Physics, University of Otago, Dunedin, New Zealand E-mail: kenneth.hughes@otago.ac.nz
Michael J.M. Williams
Affiliation:
National Institute of Water and Atmospheric Research Ltd (NIWA), Wellington, New Zealand
Rights & Permissions [Opens in a new window]

Abstract

The refreezing rate of a borehole drilled through a 252 m thick region of the Ross Ice Shelf, Antarctica, is determined using oceanographic measurements over two periods of a day. We first use a method based on the conservation of salt in the supercooled salt water of the borehole. This is compared to a model using a numerical solution of the heat equation to find the temperature distribution in the host ice, allowing ice growth to be calculated from the balance of heat fluxes at the ice/water interface. This second method broadly confirms the refreezing rates deduced from salinity measurements, giving confidence in the generalization of this simple heat-flux model to predict refreezing rates of other boreholes. Predictions from both are subject to uncertainty due to the poorly defined value of the solid fraction of ice that freezes in a supercooled volume of sea water. This is taken to be 0.5 ± 0.1 throughout this study. The predicted rates are also strongly dependent on the initial and boundary conditions chosen, but results show the initial diameter of 600 mm decreases at a rate of ~3–5 mm h−1 in an ice shelf with a minimum temperature of −22°C.

Information

Type
Instruments and Methods
Copyright
Copyright © International Glaciological Society 2013
Figure 0

Fig. 1. Map showing the location of the borehole on the Ross Ice Shelf (red dot), where the ice was 252 m thick.

Figure 1

Fig. 2. The variation, with water depth and time, of salinity, temperature, buoyancy frequency squared and deviation of temperature from freezing point (negative values indicate supercooling). (a–d) The ten oceanographic casts starting at 03:12 8 December 2010 (UT); (e–h) casts starting at 23:09 12 December 2010 (UT). Plots are truncated to enlarge the region of interest. The legends refer to the number of hours and minutes at which each cast started relative to the first. The uncertainty in the supercooling measurement is shown in the appropriate panels.

Figure 2

Fig. 3. A still image from the down-hole video recording. The camera is looking down onto the bag of the light housing. Ice crystals can be seen loosely accreted to the hole walls. Detached ice crystals can also be seen in suspension floating across the back of the light housing.

Figure 3

Fig. 4. Cross-sectional view of an ice shelf, showing the heights of significance (values given in Table 1).

Figure 4

Table 1. Significant measurements at the borehole site, not all of which are independent. NSL denotes nominal sea level

Figure 5

Fig. 5. Timeline of important events described in the text and the modelled heat flux (Eqns (3–6)) through the borehole wall. The reamer first entered the borehole at 04:58 7 December 2010 (UT).

Figure 6

Fig. 6. Mean temperature and salinity of casts starting 03:12 8 December 2010 (solid curve) and 23:09 12 December 2010 (dashed curve). Times given in UT. The horizontal grey line indicates the base of the borehole.

Figure 7

Fig. 7. Cross-sectional view of the growth inside the borehole. The radius at time ti is the average position of the diffuse interface. The shaded background represents the solid ice through which the hole was drilled, whereas the refrozen annulus is a mix of ice and sea water. Not to scale.

Figure 8

Table 2. Variables used in salinity-derived closure calculations

Figure 9

Fig. 8. The change in radius calculated from salinity measurements starting (a) 03:12 8 December 2010 (UT) and (b) 23:09 12 December 2010 (UT). The radii, averaged in 40 m depth bins, are non-dimensionalized and time is measured relative to the first cast in each set. R0 is estimated to be 0.28 m and ϕ = 0.5.

Figure 10

Table 3. Variables used in the heat-flux model

Figure 11

Fig. 9. (a) Temperature and density profiles through the ice shelf (Bender and Gow, 1961). Both the vertically scaled raw temperature data (circles) and fit used in this study (solid curve) are shown. (b) The variation of thermal diffusivity of ice with depth.

Figure 12

Fig. 10. (a) Cross-sectional view of half of the borehole, showing the different regions of ice and water and their respective thermal conductivities. An arrow represents a heat flux across the surface. (b) Expected temperature distribution in the water, new ice and host ice.

Figure 13

Fig. 11. (a) Evolution of the borehole radius, R, during (a) first closure and (b) second closure for ϕ = 0.5. Thin curves are separated by 6 hours and thick curves by 24 hours, with time measured relative to the moment the reamer is removed from the hole. Ice growth is delayed by 3 and 9 hours for first and second closure, respectively (see text). The vertical grey lines indicate the radius of the CTD profiler frame.

Figure 14

Fig. 12. Comparison of the refreezing rates calculated from salinity measurements (markers, 20 m depth averages) and the heat-flux model (curves). Refreezing rates, averaged over the period CTD casts were taken, are the gradient of a least-squares, linear fit to the radius over time. Uncertainties in the SVC (salinity variation calculation) results are due to both the standard error of the refreezing rate (Fig. 8) and the uncertainties in initial radius and the value of ϕ. Uncertainty in the HFM (heat-flux model) results, shown by the grey swath, is due to uncertainty in ϕ and the initial radius.