Hostname: page-component-74656f9884-8r8nv Total loading time: 0 Render date: 2026-11-08T08:33:02.453Z Has data issue: false hasContentIssue false

Handling Overdispersion in CRONUS-Earth Intercomparison Measurements: A Bayesian Approach

Published online by Cambridge University Press:  08 May 2017

Paul Muzikar*
Affiliation:
Department of Physics and Astronomy, Purdue University, West Lafayette, IN 47907
Brent Goehring
Affiliation:
Department of Earth and Environmental Sciences, Tulane University, New Orleans, LA 70118
Nathaniel Lifton
Affiliation:
Department of Earth, Atmospheric, and Planetary Sciences and Department of Physics and Astronomy, Purdue University, West Lafayette, IN 47907
*
*Corresponding author. Email: pmuzikar@purdue.edu.
Rights & Permissions [Opens in a new window]

Abstract

The recently completed CRONUS-Earth project broadly studied the production systematics of terrestrial in-situ cosmogenic nuclides and also incorporated an intercomparison study in which multiple labs measured various nuclides in homogenized geologic materials. Aliquots of these materials were measured in several labs for multiple nuclides, and the results combined to determine benchmark, consensus values. Results for some of these samples exhibited overdispersion, meaning that the measurements from the various labs differed by more than we would expect, given the quoted uncertainties. A traditional way to handle overdispersion is to add an extra amount to the variance of each lab. Another approach is to use a method that identifies potential outliers and then gives the outliers less weight in determining the final answer. A group of such methods is based on Bayesian thinking; one relatively simple member of this group was first proposed by Press (1997). We review the Press method and then apply it to the CRONUS data sets. We compare these results to those obtained by the added variance method and discuss the implications.

Information

Type
Research Article
Copyright
© 2017 by the Arizona Board of Regents on behalf of the University of Arizona 
Figure 0

Figure 1 This shows the (unnormalized) pdf (probability density function) for the concentration of 3He in the CRONUS-P sample. The x-axis is units of 109 atoms per gram. Equations (2), (4), and (6) were used, with a value of s=0.35.

Figure 1

Figure 2 This illustrates how our CRONUS-P 3He results depend on the parameter s. We plot, σX, and <β> as functions of s. Note that and σX are in units of 109 atoms per gram.

Figure 2

Figure 3 The y-axis plots, for each of the labs that measured 3He in the CRONUS-P sample, the probability that its result is correct. The x-axis displays the concentration measured by the lab, along with the one-sigma error bar. Equations (7)–(10) were used to do the calculation.

Figure 3

Table 1 14C CRONUS-A data.

Figure 4

Figure 4 This shows the (unnormalized) pdf for the concentration of 14C in the CRONUS-A sample. The x-axis is in units of 105 atoms per gram. We used a value of s=0.55, as discussed in the section “CRONUS-A 14C Results.”

Figure 5

Figure 5 This illustrates how our CRONUS-A 14C results depend on the parameter s. We plot , σX, and <β> as functions of s. Note that and σX are in units of 105 atoms per gram.

Figure 6

Figure 6 The y-axis plots, for each of the labs that measured 14C in the CRONUS-A sample, the probability that its result is correct. The x-axis displays the concentration measured by the lab, along with the one-sigma error bar. Equations (7)–(10) were used to do the calculation.

Figure 7

Table 2 Results for all CRONUS intercomparison materials.

Figure 8

Figure 7 This plots, for each sample material, the value of the overdispersion ratio versus the value of <β>. The overdispersion ratio is defined to be $$\xi /\!\mu $$, and one σ uncertainties are shown for β.