Hostname: page-component-6898cfcb55-cbk24 Total loading time: 0 Render date: 2026-11-11T04:56:23.856Z Has data issue: false hasContentIssue false

Arterial switch procedure and hybrid muscular ventricular septal defect closure in a patient with d-transposition of the great arteries and multiple ventricular septal defects: a case report and literature review

Published online by Cambridge University Press:  14 November 2019

Jack J. C. Gibb
Affiliation:
Department of Intensive Care, Bristol Royal Hospital for Children, Bristol, UK
Massimo Caputo
Affiliation:
Department of Cardiac Surgery, Bristol Heart Institute, Bristol, UK
Demetris Taliotis*
Affiliation:
Department of Cardiology, Bristol Royal Hospital for Children, Bristol, UK
*
Author for correspondence: Dr D. Taliotis, Department of Cardiology, Bristol Royal Hospital for Children, King Edward Building, 24 Upper Maudlin Street, Bristol BS2 8BJ, UK. Tel: +44117 342 8856; E-mail: demetris.taliotis@uhbristol.nhs.uk
Rights & Permissions [Opens in a new window]

Abstract

Hybrid cardiac surgery involves simultaneous catheter based and surgical treatment of heart diseases. We report a complete repair of dextro-transposition of the great arteries and perimembranous and muscular ventricular septal defects in a 5-month-old girl. This included an arterial switch operation followed by an off-bypass, echocardiographically guided per-ventricular muscular ventricular septal defect closure.

Information

Type
Brief Report
Copyright
© Cambridge University Press 2019 
Figure 0

Figure 1.Trans-oesophageal images: (a) Mid-oesophageal four-chamber view showing a mid-trabecular muscular VSD measuring 6 mm. (b) Mid-oesophageal four-chamber view with a 0.035 J-Tip wire through the VSD to the left ventricle. (c) Mid-oesophageal four-chamber view showing the 6Fr short sheath through the VSD to the left ventricle. (d) Trans-gastric view showing a 6 mm VSD Occluder device in a good position with well-deployed left and right ventricular discs.