Hostname: page-component-7b7567c8c-7pwfn Total loading time: 0 Render date: 2026-11-16T02:45:13.755Z Has data issue: false hasContentIssue false

Electroosmosis over non-uniformly charged surfaces: modified Smoluchowski slip velocity for second-order fluids

Published online by Cambridge University Press:  15 November 2016

Uddipta Ghosh
Affiliation:
Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, West Bengal, India
Kaustav Chaudhury
Affiliation:
Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, West Bengal, India
Suman Chakraborty*
Affiliation:
Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, West Bengal, India
*
†Email address for correspondence: suman@mech.iitkgp.ernet.in

Abstract

In the present paper we focus on deriving the modified Smoluchowski slip velocity of second-order fluids, for electroosmotic flows over plane surfaces with arbitrary non-uniform surface potential in the presence of thin electric double layers (EDLs). We employ matched asymptotic expansion to stretch the electric double layer and subsequently apply regular asymptotic expansions taking the Deborah number ( $De$ ) as the gauge function. Modified slip velocities correct up to $O(De^{2})$ are presented. Two sample cases are considered to demonstrate the effects of viscoelasticity on slip velocity: (i) an axially periodic patterned potential and (ii) a step-change-like variation in the surface potential. The central result of our analysis is that, unlike Newtonian fluids, the electroosmotic slip velocity for second-order fluids does not, in general, align with the direction of the applied external electric field. Proceeding further forward, we show that the slip velocity in a given direction may, in fact, depend on the applied electric field strength in a mutually orthogonal direction, considering three dimensionality of the flow structure. In addition, we demonstrate that the modified slip velocity is not proportional to the zeta potential, as in the cases of Newtonian fluids; rather it depends strongly on the gradients of the interfacial potential as well. Our results are likely to have potential implications so far as the design of charge modulated microfluidic devices transporting rheologically complex fluids is concerned, such as for mixing and bio-reactive system analysis in lab-on-a-chip-based micro-total-analysis systems handling bio-fluids.

Information

Type
Papers
Copyright
© 2016 Cambridge University Press 
Figure 0

Figure 1.A schematic representation of the flow geometry. The origin and the axis system rest on the surface. This surface bears a non-uniform charge of the form, $\unicode[STIX]{x1D70E}^{\prime }(x^{\prime },z^{\prime })$. An electric field of magnitude $E_{0}$ (represented by the thick red line) is applied parallel to the surface in a direction $\hat{\boldsymbol{e}}$. This unit vector $\hat{\boldsymbol{e}}$ makes an angle $\unicode[STIX]{x1D703}$ with the $x$ axis. The fluid here obeys a second-order constitute relationship.

Figure 1

Figure 2.Variation in slip velocity ($u_{s}$) versus $x$, for four different values of $De=0$ (Newtonian), 0.1, 0.2 and 0.3. The potential here is periodically varying along the wall, with the expression, $\unicode[STIX]{x1D701}^{\prime }(x^{\prime })=\unicode[STIX]{x1D701}_{0}[n+m\cos (2\unicode[STIX]{x03C0}x^{\prime }/L)]$. Here we have taken $n=0.5$, $m=1$ and $\unicode[STIX]{x1D6FD}=1.5$.

Figure 2

Figure 3.Set-up for the numerical computation. The governing equations and the boundary conditions are presented in the set-up for comprehensiveness. The domain size is chosen as $2\unicode[STIX]{x03C0}\times 10$ ensuring lengthwise periodicity and an infinite domain along the transverse direction, as required in our analysis. We perform simulations with grid resolution $50\times 600$. We consider non-uniformly spaced grids, and the successive ratios between two consecutive grid sizes are 1.05. The arrow shows the direction of non-uniform spacing. Note that the expressions for excess polymeric stresses $\unicode[STIX]{x1D64E}$ have been given in § 2. Here, $\unicode[STIX]{x1D6FF}=0.01$. Other relevant details have been mentioned within the figure itself.

Figure 3

Figure 4.Comparison between numerical (marker) and analytical (lines) solutions for a periodic zeta potential for four different values of $De=0.04$, 0.08, 0.11 and 0.15. We have compared the solutions for the quantity, $\unicode[STIX]{x0394}u_{s}=u_{s}-u_{newt.}$, i.e. the change in the slip velocity for second-order fluids. Here, $u_{s}$ is the slip velocity for second-order fluids and $u_{newt.}$ is that of Newtonian fluids. Values of other parameters are as follows: $\unicode[STIX]{x1D6FD}=0.5$,$m=0.2$, $n=0.5$, $\unicode[STIX]{x1D6FF}=0.01$. The numerical solutions have been depicted for the location $y=0.013$, i.e. just outside the EDL.

Figure 4

Figure 5.Comparison between analytical scaling (lines) and numerical solutions (markers) for the normal stress ($\unicode[STIX]{x1D70F}_{xx}$) inside the EDL as a function of $\unicode[STIX]{x1D6FF}$. Our analytical scaling suggests that for second-order fluids, $\unicode[STIX]{x1D70F}_{xx}\sim \unicode[STIX]{x1D6FF}^{-2}$ in the EDL, whereas for a Newtonian fluid, $\unicode[STIX]{x1D70F}_{xx}\sim \unicode[STIX]{x1D6FF}^{0}$, i.e. has a constant value inside the EDL. The exact same trend is indeed reflected by the numerical simulations. The rest of the parameters have been taken as follows: $\unicode[STIX]{x1D6FD}=0.5$, $n=0.5$, $m=0.2$.

Figure 5

Figure 6.Variation in slip velocity ($u_{s}$) versus $x$ for four different values of $De=0$ (Newtonian), 0.2 and 0.35. The potential here mimics a step-change-like variation, given by, $\unicode[STIX]{x1D701}^{\prime }(x^{\prime })=1/2\cdot ((\unicode[STIX]{x1D701}_{1}^{\prime }+\unicode[STIX]{x1D701}_{2}^{\prime })+(\unicode[STIX]{x1D701}_{2}^{\prime }-\unicode[STIX]{x1D701}_{1}^{\prime })\cdot \tanh (x^{\prime }/d))$. This kind of variation resembles that of a step change in the potential, from $\unicode[STIX]{x1D701}_{1}$ to $\unicode[STIX]{x1D701}_{2}$. In the inset we have shown how the potential varies along the surface. Here, we have taken $\unicode[STIX]{x1D701}_{2}=0.2$ and $\unicode[STIX]{x1D6FD}=1.75$.

Figure 6

Figure 7.Vector plot of slip velocity ($\boldsymbol{v}_{s}=u_{s}\hat{\boldsymbol{e}}_{\boldsymbol{x}}+w_{s}\hat{\boldsymbol{e}}_{\boldsymbol{z}}$) on the $xz$ plane for an applied electric field at an angle $\unicode[STIX]{x1D703}=\unicode[STIX]{x03C0}/4$ with the $x$ axis, denoted by the red arrow. Here, (a) is for Newtonian fluids and (b) is for second-order fluids, with $De=0.35$, $b=1$. Other parameters have the values: $\unicode[STIX]{x1D6FD}=3$, $m=1$, $n=0$. The quantities in the vector plot have been scaled with a value 1.8.