Hostname: page-component-74656f9884-rdgjk Total loading time: 0 Render date: 2026-11-07T22:43:44.885Z Has data issue: false hasContentIssue false

Intra-aortic balloon counterpulsation in a patient with the failing Fontan circulation

Published online by Cambridge University Press:  22 December 2006

Ujjwal K. Chowdhury
Affiliation:
Department of Cardiothoracic and Vascular Surgery, All India Institute of Medical Sciences, New Delhi, India
Shyam S. Kothari
Affiliation:
Department of Cardiology, Cardiothoracic Centre, All India Institute of Medical Sciences, New Delhi, India
Ganapathy K. Subramaniam
Affiliation:
Department of Cardiothoracic and Vascular Surgery, All India Institute of Medical Sciences, New Delhi, India
Rights & Permissions [Opens in a new window]

Abstract

We report a 23-year-old patient undergoing functionally univentricular repair who developed cardiac failure due primarily to systemic ventricular dysfunction. The failing Fontan circulation was successfully re-established using intra-aortic balloon counterpulsation. Aortic counterpulsation facilitates recovery of systemic ventricular function, and appears to be a reasonable alternative in select instances of cardiac failure in patients with the Fontan circulation.

Information

Type
Brief Report
Copyright
2007 Cambridge University Press
Figure 0

Table 1.