Hostname: page-component-74656f9884-j7cmm Total loading time: 0 Render date: 2026-11-07T12:24:22.664Z Has data issue: false hasContentIssue false

Evaluation of wire electro discharge machining characteristics of Ti50Ni50−xCux shape memory alloys

Published online by Cambridge University Press:  18 May 2016

Mallaiah Manjaiah*
Affiliation:
Department of Mechanical Engineering Science, University of Johannesburg, Kingsway Campus, Johannesburg-2006, South Africa
Rudolph Frans Laubscher
Affiliation:
Department of Mechanical Engineering Science, University of Johannesburg, Kingsway Campus, Johannesburg-2006, South Africa
Sannayellapa Narendranath
Affiliation:
Department of Mechanical Engineering, National Institute of Technology Karnataka, Surathkal-575025, India
Sathyappa Basavarajappa
Affiliation:
Department of Studies in Mechanical Engineering, University B.D.T. College of Engineering, Davangere-577004, Karnataka, India
Vinayak Neelakanth Gaitonde
Affiliation:
Department of Industrial and Production Engineering, B. V. B. College of Engineering and Technology, Hubli-580031, Karnataka, India
*
a)Address all correspondence to this author. e-mail: manjaiahgalpuji@gmail.com

Abstract

The machining of shape memory alloys (SMAs) is fairly essential and integral part in the manufacture of components for utilizing in engineering applications. An effort has been made in the present work to study the effect of wire electro discharge machining process parameters such as pulse on time (Ton), pulse off time (Toff) and servo voltage (SV) have been analyzed on material removal rate and surface roughness. The investigation clearly reveals that an increased pulse on time with decrease in pulse off time as well as SV increases the amount of material removed in machining of SMAs. On the other hand, the surface roughness increases with increased pulse on time and decreases with increased pulse off time as well as SV. The surface topography of the machined surface was analyzed using scanning electron microscope (SEM) and confocal micrographs. Phase changes on the machined surface with respect to pulse on time and SV were evaluated from X-ray diffractometer (XRD) analysis.

Information

Type
Articles
Copyright
Copyright © Materials Research Society 2016 
Figure 0

FIG. 1. Workpiece profile machined for the present investigation.

Figure 1

FIG. 2. Confocal microscope used for measuring the surface roughness.

Figure 2

TABLE I. Fixed and control parameters with their identified levels.

Figure 3

TABLE II. FFD and the experimental results of Ti50Ni40Cu10 and Ti50Ni30Cu20 alloys.

Figure 4

TABLE III. ANOVA for MRR (Ti50Ni40Cu10 SMA)a.

Figure 5

TABLE IV. ANOVA for MRR (Ti50Ni30Cu20 SMA)a.

Figure 6

FIG. 3. Effect of process parameters on MRR (a) Ti50Ni40Cu10 and (b) Ti50Ni30Cu20.

Figure 7

TABLE V. ANOVA for Ra (Ti50Ni40Cu10 SMA)a.

Figure 8

TABLE VI. ANOVA for Ra (Ti50Ni30Cu20 SMA)a.

Figure 9

FIG. 4. Effects of process parameters on surface roughness (a) Ti50Ni40Cu10 and (b) Ti50Ni30Cu20.

Figure 10

FIG. 5. 3D surface topography of WED machined Ti50Ni40Cu10 SMA (a) Ton = 120 µs, Toff = 55 µs, SV = 50 V, (b) Ton = 125 µs, Toff = 55 µs, SV = 50 V, and (c) Ton = 130 µs, Toff = 55 µs, SV = 50 V.

Figure 11

FIG. 6. SEM micrographs of machined Ti50Ni40Cu10 SMA (a) Ton = 120 µs, Toff = 55 µs, SV = 50 V, (b) Ton = 125 µs, Toff = 55 µs, SV = 50 V, and (c) Ton = 130 µs, Toff = 55 µs, SV = 50 V.

Figure 12

FIG. 7. SEM micrographs of machined Ti50Ni30Cu20 SMA (a) Ton = 125 µs, Toff = 55 µs, SV = 80 V (b) Ton = 120 µs, Toff = 48 µs, SV = 20 V.

Figure 13

FIG. 8. (a): XRD analysis of Ti50Ni40Cu10 SMA after WED-machining for varying pulse on time at constant pulse off time −62 µs and SV −80 V. (b): XRD analysis of Ti50Ni40Cu10 SMA after WED-machining for varying SV at constant pulse on time −120 µs, and pulse off time −62 µs.