Face and content validation of additive manufacturing temporal bone specimens

Published online by Cambridge University Press:  11 November 2024

Jesslyn Clarance Lamtara*
Affiliation:
Department of Surgery (Otolaryngology), University of Melbourne, VIC, Australia
Sudanthi Wijewickrema
Affiliation:
Department of Surgery (Otolaryngology), University of Melbourne, VIC, Australia
Jean-Marc Gerard
Affiliation:
Department of Surgery (Otolaryngology), University of Melbourne, VIC, Australia The Royal Victorian Eye and Ear Hospital, Melbourne, VIC, Australia
Stephen O’Leary
Affiliation:
Department of Surgery (Otolaryngology), University of Melbourne, VIC, Australia The Royal Victorian Eye and Ear Hospital, Melbourne, VIC, Australia
*
Corresponding author: Jesslyn Clarance Lamtara; Email: jlamtara@student.unimelb.edu.au
Rights & Permissions [Opens in a new window]

Abstract

Background

Otology training solely using cadavers is challenging because of scarcity and high costs. The use of additive manufacturing technology is a promising alternative. This study aimed to qualitatively validate new additive manufacturing temporal bone specimens for their realism and ability to train surgical skills.

Methods

Three additive manufacturing models generated using cadaveric temporal bones were evaluated. Three otologists with experience as trainers dissected and evaluated each specimen.

Results

The additive manufacturing specimens scored an average of 4.26 ± 0.72 (out of 5) points and received positive feedback. The agreement between the three expert raters was high (intra-class correlation coefficient of 0.745).

Conclusion

The results suggested that the additive manufacturing temporal bones were able to faithfully reproduce a training experience similar to that on cadaveric temporal bones. Further studies that investigate the effectiveness of these specimens in training surgical skills are needed before integrating them into surgical training curricula.

Information

Type
Main Article
Copyright
© The Author(s), 2024. Published by Cambridge University Press on behalf of J.L.O. (1984) LIMITED.
Figure 0

Figure 1. Axial cross-sections through the cochlea of the three cases of additive manufacturing temporal bone: healthy normal bone (a), healthy highly pneumatised bone (b) and healthy sclerotic bone (c). The cutting plane is in pink, while the structures cochlea, facial nerve and sigmoid sinus are coloured in light blue, purple and dark blue, respectively. Note the difference in pneumatisation of the three specimens.

Figure 1

Figure 2. The three cases of additive manufacturing temporal bones after drilling: healthy normal bone (a), healthy highly pneumatised bone (b) and healthy sclerotic bone (c).

Figure 2

Figure 3. Bland–Altman plots of the overall specimen results of the three raters: (a) rater 1 and rater 2, (b) rater 1 and rater 3, and (c) rater 2 and rater 3. Numbers in the bubbles represent the number of repetitions of agreement between each pair of raters at that point (the number of instances a given difference in the ratings with respect to their mean occurred).

Figure 3

Table 1. Face and content validity questionnaire responses of overall specimens from the three raters

Figure 4

Figure 4. Face and content validity questionnaire responses for healthy normal bone specimens from the three raters: (a) anatomical realism rating, (b) usefulness as a training tool rating and (c) overall reaction rating.

Figure 5

Figure 5. Face and content validity questionnaire responses of healthy highly pneumatised bone specimens from the three raters: (a) anatomical realism rating, (b) usefulness as a training tool rating and (c) overall reaction rating.

Figure 6

Figure 6. Face and content validity questionnaire responses of healthy sclerotic bone specimens from the three raters: (a) anatomical realism rating, (b) usefulness as a training tool rating and (c) overall reaction rating.

Figure 7

Table 2. Comparison of the face and content validity questionnaire scores of Da Cruz and Francis,12 Chien et al.14 and this study, which used the same questionnaire

Figure 8

Table 3. Comparison of the face and validity scores between existing additive manufacturing temporal bone specimens that used various questionnaires*