High-power terahertz (THz) pulses are important for material analysis and ultrafast spectroscopy, but existing sources barely achieve high field strength and average power simultaneously. Tilted-pulse-front pumping (TPFP) improves THz conversion efficiency, but its optimal configuration is highly dependent on pump parameters. Focusing on high single-pulse energy (millijoule level) and a short pulse duration (226 fs), this study systematically evaluates two TPFP configurations: the reflective grating and echelon mirror. Experimental results show that the echelon mirror configuration achieves a 0.4% conversion efficiency and a 51.7 mW average THz power, exceeding the performance of the grating configuration, which reaches 0.26% and 41.8 mW, respectively. These results confirm that combining short pulses with the echelon mirror enhances both conversion efficiency and average THz power under high-power pumping, providing experimental guidance for high-power strong-field THz sources for material manipulation and biomedical imaging.