We partner with a secure submission system to handle manuscript submissions.
Please note:
You will need an account for the submission system, which is separate to your Cambridge Core account. For login and submission support, please visit the
submission and support pages.
Please review this journal's author instructions, particularly the
preparing your materials
page, before submitting your manuscript.
Click Proceed to submission system to continue to our partner's website.
To save this undefined to your undefined account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you used this feature, you will be asked to authorise Cambridge Core to connect with your undefined account.
Find out more about saving content to .
To send this article to your Kindle, first ensure no-reply@cambridge.org is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about sending to your Kindle.
Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
Legionella pneumophila serogroup 1 was isolated from post mortem specimens from 13 out of 58 patients with pneumonia diagnosed at autopsy. The results of a study undertaken in the hospital environment showed that the water plumbing system was colonized with L. pneumophila serogroup 1 which could also be isolated from respiratory devices filled with tap water. Control measures instituted are described.
This survey assessed the maintenance of evaporative cooling towers in Glasgow, following two Legionnaires' disease outbreaks. Information was obtained from 76 of 81 premises and a maintenance score was calculated for each of 174 towers. The quality of maintenance was extremely varied (range of maintenance scores, 8–30 mean, 22 (S. D., 5.0); median, 23; maximum possible, 33) and some towers were neglected. Breaches of maintenance principles were mainly structural and organizational, e.g. inadequate drift control, rather than failure to use chemicals. Low maintenance scores were associated with no log book, no guidelines, no change in procedures in last 5 years, solitary cooling towers, and towers on industrial premises. Despite intense publicity the standard of cooling tower maintenance in Glasgow remained a concern. Information campaigns directed at those responsible for cooling–tower maintenance are neccessary.
Following the occurrence of five cases of Legionnaires' disease among patients and therapists at a French hot spring spa, a series of cleansing procedures and an epidemiological study were undertaken. During a 3-month period, the spring water was repeatedly sampled. Serum samples were taken from 689 randomly selected patients, 230 therapists, 134 administrative staff and a control group of 904 blood donors.
Legionellaceae were present in the spring water at concentrations of 103–1055 colony forming units/1. Fifteen different species or serogroups were isolated with Legionella pneumophila serogroups 3 and 1 predominating. No clinical cases of Legionnaires disease were observed during the study. However, 11% of the therapists and 5% of the patients either had a high titre of antibody (≥256) to at least one species or serogroup or seroconverted during the study. Mean antibody titres in the three study groups were significantly higher than those in the blood donors against 11 of the 32 legionella antigens tested. Nine of these 11 antigens corresponded to species or serogroups isolated from the spring water. The highest mean antibody titres in all three study groups were against L. pneumophila serogroup 3, the most common legionella in the spring water.
These findings have important implications for the maintenance of adequate standards of hygiene, bacteriological sampling and clinical surveillance in this and similar establishments.
Burden of disease analyses can quantify the relative impact of different exposures on population health outcomes. Gastroenteritis where the causative pathogen was not determined and respiratory illness resulting from exposure to opportunistic pathogens transmitted by water aerosols have not always been considered in waterborne burden of disease estimates. We estimated the disease burden attributable to nine enteric pathogens, unspecified pathogens leading to gastroenteritis, and three opportunistic pathogens leading primarily to respiratory illness, in Ontario, Canada (population ~14 million). Employing a burden of disease framework, we attributed a fraction of annual (year 2016) emergency department (ED) visits, hospitalisations and deaths to waterborne transmission. Attributable fractions were developed from the literature and clinical input, and unattributed disease counts were obtained using administrative data. Our Monte Carlo simulation reflected uncertainty in the inputs. The estimated mean annual attributable rates for waterborne diseases were (per 100 000 population): 69 ED visits, 12 hospitalisations and 0.52 deaths. The corresponding 5th–95th percentile estimates were (per 100 000 population): 13–158 ED visits, 5–22 hospitalisations and 0.29–0.83 deaths. The burden of disease due to unspecified pathogens dominated these rates: 99% for ED visits, 63% for hospitalisations and 40% for deaths. However, when a causative pathogen was specified, the majority of hospitalisations (83%) and deaths (97%) resulted from exposure to the opportunistic pathogens Legionella spp., non-tuberculous mycobacteria and Pseudomonas spp. The waterborne disease burden in Ontario indicates the importance of gastroenteritis not traced back to a particular pathogen and of opportunistic pathogens transmitted primarily through contact with water aerosols.
The aim of this study was to determine what weaning foods and food preparation practices expose children to a high risk of diarrhoeal disease through exposure to a contaminated diet. Bacterial contamination of 897 food and 896 drinking water samples was assessed in a water and santitation intervention project.
The geometric mean of faecal coliforms per g or ml was 7·5 x 103 in left-over rice, 1·4 x 102 in other types of boiled rice, 2·5 x 102 in milk, 4·8 in household drinking water, and 3·5 in bread. Multiplication of faecal coliforms occurred when there was a delay of more than 4 h between preparation and consumption of food. All samples were more contaminated in the rainy than in the dry season. Strategies to reduce contamination should therefore focus on ‘wet’ foods, early consumption after preparation, and re–heating of left–over foods. Understanding the reasons for the faulty practices is also essential to the formulation of effective measures.
Hand hygiene is a simple, low-cost intervention that may lead to substantial population-level effects in suppressing acute respiratory infection epidemics. However, quantification of the efficacy of hand hygiene on respiratory infection in the community is lacking. We searched PubMed for randomised controlled trials on the effect of hand hygiene for reducing acute respiratory infections in the community published before 11 March 2021. We performed a meta-regression analysis using a Bayesian mixed-effects model. A total of 105 publications were identified, out of which six studies reported hand hygiene frequencies. Four studies were performed in household settings and two were in schools. The average number of handwashing events per day ranged from one to eight in the control arms, and four to 17 in the intervention arms. We estimated that a single hand hygiene event is associated with a 3% (80% credible interval (−1% to 7%)) decrease in the daily probability of an acute respiratory infection. Three of these six studies were potentially at high risk of bias because the primary outcome depended on self-reporting of upper respiratory tract symptoms. Well-designed trials with an emphasis on monitoring hand hygiene adherence are needed to confirm these findings.
A novel water quality intervention that consists of point-of-use water disinfection, safe storage and community education was field tested in Bolivia. A total of 127 households in two periurban communities were randomized into intervention and control groups, surveyed and the intervention was distributed. Monthly water quality testing and weekly diarrhoea surveillance were conducted. Over a 5-month period, intervention households had 44% fewer diarrhoea episodes than control households (P=0·002). Infants <1 year old (P=0·05) and children 5–14 years old (P=0·01) in intervention households had significantly less diarrhoea than control children. Campylobacter was less commonly isolated from intervention than control patients (P=0·02). Stored water in intervention households was less contaminated with Escherichia coli than stored water in control households (P<0·0001). Intervention households exhibited less E. coli contamination of stored water and less diarrhoea than control households. This promising new strategy may have broad applicability for waterborne disease prevention.
Twelve patients in a large teaching hospital contracted Legionnaires' disease over a period of 11 months. The source was a domestic hot water system in one of the hospital blocks, which was run at a temperature of 43 °C. Five different subtypes of Legionella pneumophila serogroup 1 have been isolated from water in different parts of the hospital, over a period of time. Only one subtype, Benidorm RFLP 14, was implicated in disease. Circumstantial evidence suggested that the outbreak may have been due to recent colonization of the hot water system with a virulent strain of Legionella pneumophila. The outbreak was controlled by raising the hot water temperature to 60 °C, but careful surveillance uncovered two further cases in the following 30 months. Persistent low numbers of Legionella pneumophila were isolated from the domestic hot water of wards where Legionnaires' disease had been contracted, until an electrolytic unit was installed releasing silver and copper ions into this supply.
Over the past two decades, the incidence of legionellosis has been steadily increasing in the United States though there is noclear explanation for the main factors driving the increase. While legionellosis is the leading cause of waterborne outbreaks in the US, most cases are sporadic and acquired in community settings where the environmental source is never identified. This scoping review aimed to summarise the drivers of infections in the USA and determine the magnitude of impact each potential driver may have. A total of 1,738 titles were screened, and 18 articles were identified that met the inclusion criteria. Strong evidence was found for precipitation as a major driver, and both temperature and relative humidity were found to be moderate drivers of incidence. Increased testing and improved diagnostic methods were classified as moderate drivers, and the ageing U.S. population was a minor driver of increasing incidence. Racial and socioeconomic inequities and water and housing infrastructure were found to be potential factors explaining the increasing incidence though they were largely understudied in the context of non-outbreak cases. Understanding the complex relationships between environmental, infrastructure, and population factors driving legionellosis incidence is important to optimise mitigation strategies and public policy.
Prospective epidemiological studies of beach water pollution were conducted in Hong Kong in the summers of 1986 and 1987. For the main study in 1987, a total of 18741 usable responses were obtained from beachgoers on nine beaches at weekends. The study indicated the overall perceived symptom rates for gastrointestinal, ear, eye, skin, respiratory, fever and total illness were significantly higher for swimmers than non-swimmers; and the swimming-associated symptom rates for gastrointestinal, skin, respiratory and total illness were higher at ‘barely acceptable’ beaches than at ‘relatively unpolluted’ ones. Escherichia coli was found to be the best indicator of the health effects associated with swimming in the beaches of Hong Kong. It showed the highest correlation with combined swimming-associated gastroenteritis and skin symptom rates when compared with other microbial indicators. A linear relationship between E. coli and the combined symptom rates was established. Staphylococci were correlated with ear, respiratory and total illness, but could not be used for predicting swimming-associated health risks. They should be used to complement E. coli. The setting of health-related bathing-water quality standards based on such a study is discussed.
Outbreaks of Legionnaire's disease present a public health challenge especially because fatal outcomes still remain frequent. The aim of this study was to describe the abundance and epidemiology of Legionellaceae in the human-made environment. Water was sampled from hot-water taps in private and public buildings across the area of Göttingen, Germany, including distant suburbs. Following isolation, we used polymerase chain reaction in order to generate strain specific banding profiles of legionella isolates. In total, 70 buildings were examined. Of these 18 (26%) had the bacterium in at least one water sample. Legionella pneumophila serogroups 1, 4, 5 and 6 could be identified in the water samples. Most of the buildings were colonized solely by one distinct strain, as proven by PCR. In three cases equal patterns were found in separate buildings. There were two buildings in this study where isolates with different serogroups were found at the same time.
In 1988, there were two outbreaks of legionellosis in Bolton Health District. Altogether 37 cases of Legionnaires' disease and 23 cases of non-pneumonic legionellosis were identified. Twenty-five patients with Legionnaires' disease were associated with an engineering plant, 4 with Bolton town centre, and 8 with both the plant and town centre. Twenty-two people with non-pneumonic legionellosis were linked with the engineering plant and one with the plant and the town centre. A case-control study carried out among 37 employees with legionellosis and 109 control subjects at the plant showed that infection was associated with one of the 15 cooling towers on the site. Legionella pneumophila indistinguishable by serological and genetic typing methods was isolated from this cooling tower and from sputum samples from two patients. In the town centre, no one tower was linked with infection and L. pneumophila was not cultured from any of the nine towers identified. Control measures were implemented and to date there have been no further cases of legionellosis associated with Bolton Health District.
One hundred and seventy-nine isolates of Legionella pneumophila serogroup 1, obtained from a site associated with an outbreak of Legionnaires' disease, were examined by monoclonal antibody subgrouping, restriction fragment length polymorphism typing, restriction endonuclease analysis and plasmid content. Nine distinct phenotypes were detected but at the genotypic level all strains were closely related. The data presented indicate that phenotypic variation of a single parent strain can occur within an environmental site. The implications of these findings are discussed in relation to the investigation of outbreaks of Legionnaires' disease.
Two cases of legionellosis occurring 3 years apart were acquired in the same French thermal spa and were apparently due to the same strain of Legionella pneumophila serogroup 1, as shown by genomic macrorestriction analysis. Minor differences between the two isolates were found by random amplification PCR profiling which showed an additional band with one of the isolates. Analysis of 107 L. pneumophila strains isolated from the spa waters by genome macrorestriction failed to identify the infective strain, but a closely related L. pneumophila serogroup 3 strain differing from the clinical isolates by only one band was found. To determine if the clinical L. pneumophila serogroup 1 isolates was better adapted for intracellular multiplication than related serogroup 3 environmental isolates, the growth kinetics of six isolates were determined in co-culture with Acanthamoeba lenticulata. One clinical isolate failed to grow within amoeba, while the other clinical isolate yielded the highest increase in bacterial cell count per amoeba (1200 %) and the environmental isolates gave intermediate values. Genetic analysis of L. pneumophila isolates by DNA macrorestriction does not therefore appear to reflect their growth kinetics within amoeba, and is not sufficiently discriminatory to identify potentially virulent strains.
Forty-one clinical isolates of Legionella pneumophila from sporadic cases of legionella pneumonia were collected from laboratories throughout the United Kingdom and were compared with 300 routine environmental isolates using two panels of monoclonal antibodies, covering serogroups 1–10. Eighty-five per cent of the clinical isolates belonged to the subgroup Pontiac of serogroup 1, whilst only 13% of the environmental isolates did. Approximately half of the clinical isolates tested came from patients with a recent history of foreign travel, mainly to southern Europe.
A comparison was made between membrane filtration and centrifugation for the isolation of Legionella pneumophila from seeded water samples. Using samples of varying concentration, the optimum speed and time of centrifugation were determined and the relationship between the number of organisms present in the water and the proportion recovered was examined. Following this, sequential routine environmental waters were filtered and centrifuged in parallel.
Centrifugation and filtration using nitrocellulose filters were found to be comparable. The optimum speed and time of centrifugation was approximately 6000 g for 10 min. There was a constant proportion of viable organisms recovered irrespective of the concentration in the unspun samples.
We determined the natural history of the colonization of our hospital's potable water by culturing water approximately biweekly from 20 sites throughout the hospital for 4 years. Overall, 545 (24.7%) of the 2200 samples grew Legionella pneumophila. During hyperchlorination, 11·7% of the samples were positive while 41·6% were positive in the absence of chlorination. There was no seasonal trend towards positivity, but there was marked inter-site variation in the semi-quantitative culture results. However, a single strain of legionella (as defined by plasmid profiling) tended to persist at a site. Such a site was a unique ecological niche in that different sites in the same wing were populated by distinct strains.
The two wings of our hospital had a significantly different distribution of strains of legionella – plasmid profile type III predominated in the Victoria Wing while types II and VI predominated in Centennial Wing. Twenty-four of our 28 cases of nosocomial Legionnaires' disease occurred in the Centennial Wing. Three of the four cases in the Victoria Wing were caused by plasmid profile type III while 18 of the 24 isolates from patients who acquired their infection in the Centennial Wing were type II. We conclude that each water outlet serves as its own ecological niche of L. pneumophila.
In October 1985, six cases of legionnaires' disease were associated with a police headquarters building. Four were amongst staff who worked in or visited the communications wing of the headquarters and two cases occurred in the local community. A case-control study implicated the operations room of the communications wing as the main area associated with infection. This wing was air-conditioned and smoke tracer studies showed that drift from the exhaust as well as from the base of the cooling tower entered the main air-intake which serviced the air-conditioning system. Legionella pneumophila serogroup 1 subgroup pontiac was isolated from water and sludge in the cooling tower pond. Contaminated drift from the top of the cooling tower was probably responsible for the two community cases. An additional discovery was that symptoms suggestive of the sick-building syndrome were associated with working in this wing.
The food and water hygiene in two Liberian communities was studied in a house-to-house diarrhoea survey. The level of contamination with enterobacteria of drinking water stored in the households was significantly higher than at the water sources. Food hygiene standards were low, particularly in the urban slum where storage of cooked food for long periods led to bacterial multiplication at high levels. Infant foods were particularly heavily contaminated. It is concluded that when water supply programmes are planned, the presence of other risk factors for water-related diseases should be investigated. To ensure maximum health benefits, water projects should as a rule be accompanied by other interventions.
Daily and hourly variations in microbial indicators densities in the beach-waters of Hong Kong have been described. The levels of Escherichia coli at a number of beaches was observed to be influenced by tide, and for staphylococci, by bather numbers. The tidal influence was most obvious during spring tides; and for the effect of bathers, during neap tides. Both organisms are present in high densities in external sources of faecal pollution of bathing beaches, with the average staphylococci to E. coli ratios being 0·04–3. Staphylococci may serve as an indicator of bather density and the risk of cross-infection amongst bathers (rather than as another indicator of faecal contamination) when the average staphylococci to E. coli ratio for a bathing beach is considerably higher than 3. The variability of microbial indicator densities means the routine sampling of bathing beaches should be carried out on weekend days with maximum numbers of swimmers exposed to the water, and spread throughout the bathing season.