We partner with a secure submission system to handle manuscript submissions.
Please note:
You will need an account for the submission system, which is separate to your Cambridge Core account. For login and submission support, please visit the
submission and support pages.
Please review this journal's author instructions, particularly the
preparing your materials
page, before submitting your manuscript.
Click Proceed to submission system to continue to our partner's website.
To save this undefined to your undefined account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you used this feature, you will be asked to authorise Cambridge Core to connect with your undefined account.
Find out more about saving content to .
To send this article to your Kindle, first ensure no-reply@cambridge.org is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about sending to your Kindle.
Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
Most villagers in north-east Thailand carry water to their homes and store it in separate containers depending on its subsequent use. In one village, information on water use was collated with the bacteriological quality of stored water, water sources and fingertip-rinses. Stored water quality was a function of water-related activities rather than quality at source (P<0·0001). Specifically water used for toilet, washing dishes and cooking-related activities was much more contaminated with faecal bacteria than that used for drinking and cooking. Salmonella spp. was significantly more common in water used for washing dishes than drinking (P<0·05). Escherichia coli contamination of fingertip-rinses was strongly associated with the individual's activity prior to testing (P<0·0001); child care, food and water-related activities produced much higher levels of fingertip contamination than others. Dirty utensils used for cooking and eating were usually left to soak and faecal bacterial growth occurred in this grossly contaminated soak-water. Cross-contamination via water handling was the main mechanism of stored water pollution. These results were used to develop a hygiene intervention study presented in a companion paper.
Fifty-eight bottles of natural mineral water, taken from the point of sale, were bacteriologically examined. No coliforms or Aeromonas sp. were isolated from any sample. High total bacterial counts were found particularly in the still waters. Most of the organisms isolated in the total counts were Gram-negative rods, but Gram-positive organisms were also isolated. Gram-positive cocci were further identified, some of which were known human commensals suggesting contamination of the waters prior to bottling.
Estimation of numbers of organisms is often made using dilution series, for example when examining water samples for coliform organisms. In this paper the most probable numbers (MPNs) are calculated for a 15-tube series consisting of five replicates at three consecutive tenfold dilutions. Exact conditional probabilities are computed to replace previous approximations.
When growth is observed in several of the tubes it is not realistic to select a single MPN. Instead a most probable range (MPR) should be reported. But using an MPR creates problems when comparison has to be made with a legislated, single-valued Standard. It is suggested that the wording of the Standards should be expressed differently when the multiple tube method is used.
The survival of various faecal bacteria used as indicators of the faecal contamination of water supplies has been investigated in a tropical environment (Sierra Leone). Isolates representing the thermotolerant coliform (TtC) and faecal streptococcus (FS) groups, Clostridium perfringens and Salmonella spp. were studied over a 48 h period of immersion in water from three different sources. Survival patterns varied according to source type, but some general observations were made: a portion of the TtC group was apparently capable of substantial regrowth; FS organisms died off at a faster rate than TtC organisms initially, but survived longer; vegetative cells of C. perfringens died off rapidly; and Salmonella spp. could survive for as long as the other faecal organisms tested. The implications of results for the analysis of tropical waters for faecal contamination are discussed.
We evaluated improvements made to the mandatory notification surveillance system for Legionnaires' disease in France by estimating its sensitivity in 1995 and 1998 using a repeat capture–recapture method. A case of Legionnaires' disease was defined as a person treated for pneumonia in whom legionella had been detected. Patient details were collected from (1) mandatory notifications; (2) the National Reference Centre for Legionella; (3) a postal survey of all hospital laboratories. The three sources were cross-matched and 715 individual cases were identified. A log-linear model, which included an interaction term between mandatory notifications and both the National Reference Centre and Laboratory sources, provided an estimated total of 1124 cases (95% CI 973–1275) in 1998, a twofold increase compared with 1995. The sensitivity of the surveillance system improved from 10% in 1995 to 33% (95% CI 29–38%) in 1998. Capture-recapture methods are important tools in the evaluation of surveillance systems.
This study investigated the relationships between Legionnaires' disease (LD) incidence and weather in Glasgow, UK, by using advanced statistical methods. Using daily meteorological data and 78 LD cases with known exact date of onset, we fitted a series of Poisson log-linear regression models with explanatory variables for air temperature, relative humidity, wind speed and year, and sine-cosine terms for within-year seasonal variation. Our initial model showed an association between LD incidence and 2-day lagged humidity (positive, P = 0·0236) and wind speed (negative, P = 0·033). However, after adjusting for year-by-year and seasonal variation in cases there were no significant associations with weather. We also used normal linear models to assess the importance of short-term, unseasonable weather values. The most significant association was between LD incidence and air temperature residual lagged by 1 day prior to onset (P = 0·0014). The contextual role of unseasonably high air temperatures is worthy of further investigation. Our methods and results have further advanced understanding of the role which weather plays in risk of LD infection.
Between August and October 2003, 15 cases of Legionnaires' disease were detected in the 9th district of Rome. To identify possible sources of Legionella exposure, a matched case-control study was conducted and environmental samples were collected. Hospital discharge records were also retrospectively analysed for the period July–November 2003, and results were compared with the same period during the previous 3 years. The case-control study revealed a significantly increased risk of disease among those frequenting a specific department store in the district (OR 9·8, 95% CI 2·1–46·0), and Legionella pneumophila was isolated from the store's cooling tower. Genotypic and phenotypic analysis of human and environmental isolates demonstrated that the cluster was caused by a single strain of L. pneumophila serogroup 1, and that the cooling tower of the store was the source of infection. The increased number of hospital admissions for microbiologically undiagnosed pneumonia during the study period may indicate that some legionellosis cases were not identified.
The aim of this study was to compare the incidence of community-acquired Legionnaires' Disease in Nottingham with England and Wales and to explore reasons for any difference observed. Based on data from the National Surveillance Scheme for Legionnaires' Disease (1980–1999), the rate of infection in England and Wales was 1·3 per million/year compared with 6·6 per million/year in Nottingham. Domestic water samples were obtained from 41 (95%) of 43 Nottingham cases between 1997 and 2000. In 16 (39%) cases, Legionella sp. were cultured in significant quantities. Proximity to a cooling tower was examined using a 1[ratio ]4 case-controlled analysis. No significant difference in the mean distance between place of residence to the nearest cooling tower was noted (cases 2·7 km vs. controls 2·3 km; P=0·5). These data suggest that Nottingham does have a higher rate of legionella infection compared to national figures and that home water systems are a source.
During two legionellosis outbreak investigations, one at a geriatric centre and the other in high-rise housing for seniors, it was observed that additional cases of legionellosis occurred in nearby smaller residential settings. This apparent geographical cluster of legionellosis occurred in the same general area of a community water storage tank. No potential airborne sources in or near the area could be identified, but a community water system storage tank that was centrally located among case residences spurred an investigation of water-quality factors in the identified investigation area. Conditions conducive for Legionella growth, particularly low chlorine residuals, were found. The rate of legionellosis among residents aged ⩾50 years in the investigation areas (61·0 and 64·1/100 000) was eight times higher than in the rest of the service area (9·0/100 000) and almost 20 times higher than the statewide annual average incidence rate (3·2/100 000). A water mains flushing programme in the area was launched by the water utility, and water samples taken before and during flushing found L. pneumophila.
Despite US sanitation advancements, millions of waterborne disease cases occur annually, although the precise burden of disease is not well quantified. Estimating the direct healthcare cost of specific infections would be useful in prioritizing waterborne disease prevention activities. Hospitalization and outpatient visit costs per case and total US hospitalization costs for ten waterborne diseases were calculated using large healthcare claims and hospital discharge databases. The five primarily waterborne diseases in this analysis (giardiasis, cryptosporidiosis, Legionnaires' disease, otitis externa, and non-tuberculous mycobacterial infection) were responsible for over 40 000 hospitalizations at a cost of $970 million per year, including at least $430 million in hospitalization costs for Medicaid and Medicare patients. An additional 50 000 hospitalizations for campylobacteriosis, salmonellosis, shigellosis, haemolytic uraemic syndrome, and toxoplasmosis cost $860 million annually ($390 million in payments for Medicaid and Medicare patients), a portion of which can be assumed to be due to waterborne transmission.