Hostname: page-component-74656f9884-kv2lp Total loading time: 0 Render date: 2026-11-06T06:12:25.327Z Has data issue: false hasContentIssue false

High efficiency continuous mode RF power amplifier based on second and third harmonic manipulation

Published online by Cambridge University Press:  30 July 2020

Firas M. Ali*
Affiliation:
Department of Electrical Engineering, University of Technology, Baghdad, Iraq
Mahmuod H. Al-Muifraje
Affiliation:
Department of Electrical Engineering, University of Technology, Baghdad, Iraq
Thamir R. Saeed
Affiliation:
Department of Electrical Engineering, University of Technology, Baghdad, Iraq
*
Author for correspondence: Firas M. Ali, E-mail: firas.alraie@ieee.org
Rights & Permissions [Opens in a new window]

Abstract

Continuous mode class-J radio-frequency (RF) power amplifier is a promising technique that extends the operating bandwidth of the conventional class-B power amplifier. However, the maximum theoretical efficiency is limited to that of the class-B power amplifier. In this paper, an enhanced mode of operation for the class-J power amplifier is proposed by incorporating a third harmonic voltage component to produce an optimum waveform for maximizing the fundamental voltage component and thereby to increase the drain efficiency and introduce a new design space. A detailed derivation for the necessary relations of output power, drain efficiency, and the required harmonic load impedances is provided, showing a significant improvement in theoretical maximum efficiency from 78.5 to 89.8%. In order to confirm the developed analytic approach, a 10 W prototype amplifier model was designed and fabricated to operate within the global system for mobile communications (GSM) frequency band 850–950 MHz using a commercial GaN power high electron mobility transistor (HEMT). The experimental results have indicated that the drain efficiency of the circuit varies from 68 to 80% within the desired band.

Information

Type
Power Amplifiers
Copyright
Copyright © Cambridge University Press and the European Microwave Association 2020
Figure 0

Fig. 1. Simplified circuit model for the GaN HEMT.

Figure 1

Table 1. Evaluated drain voltage waveform factors

Figure 2

Fig. 2. Drain voltage waveform for the modified class-J mode.

Figure 3

Fig. 3. Drain voltage waveform patterns for the modified class-J PA with α as a parameter.

Figure 4

Table 2. Theoretical performance comparison between conventional and modified class-J modes

Figure 5

Fig. 4. An optimized model for the CGH40010F Packaged HEMT.

Figure 6

Fig. 5. Normalized harmonic load impedances at the current generator and package planes.

Figure 7

Fig. 6. Simulation setup for examining the behavior of the modified class-J PA mode.

Figure 8

Fig. 7. Drain voltage and current waveforms for the class-J (a) and modified class-J (b) modes for α = 1.

Figure 9

Fig. 8. Fundamental drain voltage (a) and current (b) components versus input power for the class-J and modified class-J modes when α = 1.

Figure 10

Fig. 9. Simulated drain efficiency versus input power for class-J and modified class-J modes.

Figure 11

Fig. 10. Drain current and voltage signals for two values of α. (a) α = 0, (b) α = −1 .

Figure 12

Fig. 11. Estimated harmonic load impedances for the frequency range 850–950 MHz.

Figure 13

Fig. 12. Initial design of the harmonic load network at 900 MHz.

Figure 14

Fig. 13. Circuit schematic of the optimized microstrip-line load network.

Figure 15

Fig. 14. Simulated impedances versus frequency for the optimized load network.

Figure 16

Fig. 15. Schematic diagram of the designed power amplifier circuit.

Figure 17

Fig. 16. Simulated drain voltage and current waveforms for different frequencies. (a) f=850 MHz, (b) f=900 MHz, (c) f=950 MHz.

Figure 18

Fig. 17. Photographs for the constructed power amplifier (a) and the test-setup (b).

Figure 19

Fig. 18. Simulated and measured small signal S-parameters versus frequency.

Figure 20

Fig. 19. Simulated and measured performance characteristics versus frequency.

Figure 21

Fig. 20. Simulated and measured second harmonic level versus frequency.

Figure 22

Table 3. Comparison with other recent works on class-J PAs