To save content items to your account,
please confirm that you agree to abide by our usage policies.
If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account.
Find out more about saving content to .
To save content items to your Kindle, first ensure no-reply@cambridge.org
is added to your Approved Personal Document E-mail List under your Personal Document Settings
on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part
of your Kindle email address below.
Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations.
‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi.
‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
Bicuspid aortic valve is considered to have a multifactorial origin. Some research suggests a defect in neural crest cell signalling may increase the risk of developing bicuspid aortic valve, and also impact on the proximal conduction system.
Purpose:
To examine electrocardiographic parameters in unselected newborns from the general population diagnosed with bicuspid aortic valve within 30 days after birth.
Methods:
This is a substudy of the Copenhagen Baby Heart Study; a multicentre, prospective, population-based cohort study with prenatal inclusion. Cardiac examination, including transthoracic echocardiography and electrocardiography, were obtained within 30 days after birth. Newborns diagnosed with bicuspid aortic valve were matched 1:4 with newborns with structurally normal hearts based on age, sex, gestational age, weight, and length at examination.
Results:
A total of 127 newborns with bicuspid aortic valve (84 boys, median age 11 days) and 508 controls (336 boys, median age 11 days) were included. Newborns with bicuspid aortic valve had a significantly longer PR-interval (100 vs 96 ms, p = 0.011) and QRS duration (56 vs 54 ms, p = 0.042), and a significantly lower R-wave amplitude in V6 (759 vs 906 µV, p = 0.047) compared to controls. However, when correcting for multiple testing none of the results were significant.
Conclusion:
Newborns from the general population with bicuspid aortic valve demonstrated a slightly longer PR-interval, a longer QRS duration, and a lower maximum R-wave amplitude in V6 than matched controls, although non-significant after correcting for multiple testing. This may represent early signs of conduction abnormalities, but longitudinal follow-up will provide further clarification.