To save content items to your account,
please confirm that you agree to abide by our usage policies.
If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account.
Find out more about saving content to .
To save content items to your Kindle, first ensure no-reply@cambridge.org
is added to your Approved Personal Document E-mail List under your Personal Document Settings
on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part
of your Kindle email address below.
Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations.
‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi.
‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
Shortages of disposable medical equipment can critically impair health care delivery during disasters or armed conflict. Although reprocessing single-use medical devices (SUDs) may represent the only feasible option under such conditions, evidence supporting simple, field-adapted cleaning methods is limited.
Methods:
In this exploratory study, 90 clinically used SUDs – endotracheal tubes (ETT), laryngeal mask airway (LMA), intravenous administration sets (IVS), syringes (SYR), indwelling urinary catheters (IDC), and nasogastric tubes (NGT) – were collected after surgery in a regional hospital. Devices were randomly allocated to cleaning with peracetic acid (PAA), 70% ethanol, or dishwashing detergent. Each item was brushed, immersed for ten minutes, and then air-dried. Microbiological sampling included pre-cleaning and post-cleaning cultures, and airway devices underwent Polymerase Chain Reaction (PCR) testing for 28 respiratory pathogens. Functional integrity was assessed after cleaning.
Results:
All three cleaning agents achieved statistically significant reductions in bacterial load (P < 0.05) with no difference between methods. The PCR testing detected Hemophilus influenzae (H. influenzae) and Staphylococcus aureus (S. aureus) among other pathogens in 47% of airway devices before cleaning; all post-cleaning samples were negative. No structural or functional damage was observed.
Conclusion:
Basic cleaning procedures with commonly available agents substantially reduced microbial contamination without impairing device function. These methods cannot replace validated sterilization but may serve as the only viable option when medical supply is critically constrained, such as in disasters or in armed conflict. Preparedness planning should encompass strategic stockpiling, surge production capacity, and resilient supply chains, together with rationing and substitution strategies, and - only as a last resort - protocols for cleaning and reusing single-use medical equipment.
1. Chest X-ray anteroposterior (AP) films magnify the heart and mediastinum, and obscure the left lower zone.
2. When assessing the correct positioning of internal jugular central venous catheter placement, as a rule of thumb, the tip should lie at the level of the carina and to the right of the mediastinum.
3. When assessing the correct positioning of an endotracheal tube, the tip should lie 5–7 cm above the carina.
4. When assessing the lung fields, divide the lungs into three zones: upper, middle and lower thirds. Compare each side and check for asymmetry.
5. Consolidation refers to small airways and alveoli that are filled with material – pus, fluid, blood or cells. Consolidation is not synonymous with infection.
The location of Zenker's diverticulum along with the inherent risks of aspiration at any given stage of surgery (pre-, intra- or postoperative periods) adds an element of unique difficulty in the anesthetic approach to these patients. This chapter explores the anesthetic considerations for this unique procedure. The surgical procedure is generally curative and a majority of the patients live symptom-free for the rest of their lifetime. A main concern during the induction period is to safely secure the airway without increasing the risk of aspiration. While regurgitation and aspiration may occur during induction of anesthesia and during intubation, they might still happen even after successful uneventful intubation. Pertinent perioperative evaluation should include detailed cardiovascular and nutritional status evaluation and optimization. Perforation of Zenker's diverticulum may occur during a difficult intubation, or during blind placement of a nasogastric tube.
Recommend this
Email your librarian or administrator to recommend adding this to your organisation's collection.