We partner with a secure submission system to handle manuscript submissions.
Please note:
You will need an account for the submission system, which is separate to your Cambridge Core account. For login and submission support, please visit the
submission and support pages.
Please review this journal's author instructions, particularly the
preparing your materials
page, before submitting your manuscript.
Click Proceed to submission system to continue to our partner's website.
To save this undefined to your undefined account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you used this feature, you will be asked to authorise Cambridge Core to connect with your undefined account.
Find out more about saving content to .
To send this article to your Kindle, first ensure no-reply@cambridge.org is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about sending to your Kindle.
Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
Here, we report the feasibility and long-term efficacy of a granulomatous slack skin disease (GSSD) treatment with combined high-energy photon and proton beams.
Patient and methods
A GSSD patient with abdominal disease volume 25×15×2–4 cm deep was recommended for treatment at this institution. In addition to photons and electrons, high-energy protons delivered with advanced planning techniques and patient positioning were used. The patient was irradiated to a total dose of 40 Gy by using 20 Gy matched photon and electrons followed by 20 Gy equivalent protons delivered by using innovative range compensation and patient positioning.
Results
The test patient tolerated the treatment well and is now a 10-year survivor of the disease.
Conclusions
Treatment of GSSD with protons is feasible. The range and narrow penumbra properties of the proton beam provided an ideal capability to match fields accurately to cover large volumes while also sparing underlying normal tissues.
The dosimetric and clinical advantages offered by implementation of pencil beam scanning (PBS) proton therapy for moving thoracic tumours is hindered by interplay effect. The purpose of this study is to evaluate the impact of large proton beam spot size along with adaptive aperture (AA) and various motion mitigation techniques on the interplay effect for a range of motion amplitudes in a three-dimensional (3D) respiratory motion phantom.
Materials and Methods:
Point doses using ionisation chamber (IC) and planner dose distributions with radiochromic film were compared against the corresponding treatment planning system (TPS) information. A 3D respiratory motion phantom was scanned either for static or 4D computed tomographic (CT) technique for 6-, 10- and 14-mm motion amplitudes in SI direction. For free breathing (FB) treatment, a tumour was contoured on maximum intensity projection scan and an average scan was used for treatment planning. Each FB treatment was delivered with one, three and five volumetric repaintings (VRs). Three phases (CT40–60%) were extracted from the 4D-CT scans of each motion amplitude for the respiratory-gated treatment and were used for the treatment planning and delivery. All treatment plans were made using AA and robustly optimised with 5-mm set-up and 3·5% density uncertainty. A total of 26 treatment plans were delivered to IC and film using static, dynamic and respiratory-gated treatments combinations. A percent dose difference between IC and TPS for the point dose and gamma indices for film–TPS planner dose comparison was used.
Results:
The dose profile of film and TPS for the static phantom matched well, and percent dose difference between IC and TPS was 0·4%. The percent dose difference for all the gated treatments were below 3·0% except 14-mm motion amplitude-gated treatment. The gamma passing rate was more than 95% for film–TPS comparison for all gated treatment for the investigated gamma acceptance criteria. For FB treatments, the percent dose difference for 6-, 10- and 14-mm motion amplitude was 1·4%, −2·7% and −4·1%, respectively. As the number of VR increased, the percent difference between measured and calculated values decreased. The gamma passing rate met the required tolerance for different acceptance criteria except for the 14-mm motion amplitude FB treatment.
Conclusion:
The PBS technique for the FB thoracic treatments up to 10-mm motion amplitude can be implemented with an acceptable accuracy using large proton beam spot size, AA and robust optimisation. The impact of the interplay effect can be reduced with VR and respiratory-gated treatment and extend the treatable tumour motion amplitude.
Intensity-modulated radiation therapy (IMRT) has revolutionised the way head and neck cancers can be treated. It allows for a more conformal treatment plan when compared to 3D conformal radiation therapy. In paediatric patients, however, IMRT continues to deliver higher doses than desirable. Proton beam therapy on the other hand has the potential to further spare organs-at-risk.
Methods:
A 16-year-old boy with a left-sided paraganglioma of the left base of skull manifested by headaches, neck pain and tongue cramping was simulated, planned and treated with proton therapy with significant contralateral organ-at-risk sparing.
Results:
For this patient, dosimetric plan comparison between photon and proton plans clearly showed better sparing of contralateral organs-at-risk with protons. The contralateral parotid gland received a mean dose of 386·3 cGy with photons, whereas it received 1·3 cGy (CGE) in the proton plan.
Conclusions:
The dosimetric advantage of proton beam over photon beam therapy has successfully been demonstrated in this case study for a paediatric patient with a head and neck tumour. Sparing of contralateral structures is especially important in paediatric patients who are at a greater risk of secondary malignancies due to possible long life expectancy.
Conjunctival squamous cell carcinoma (SCC) is a rare tumour of the ocular region and microscopic radical surgical is difficult. There are no single guidelines for therapeutic management and the role of radiation therapy is not clearly defined although conventionally photon or electron beams are used. Proton beam radiotherapy (PBRT) is a new option for a conservative approach and allows good sparing of the organs at risk.
Materials and methods:
After surgical resection, we collected 15 cases treated at our institution with PBRT. The dose delivered was between 48 and 60 Gy relative biological effectiveness (RBE), with fractions of 12–15 Gy RBE.
Results:
After an average period of 48 months, the patients achieved excellent disease control (overall survival and disease-free survival: 86·6%), with minimal acute and late toxicity.
Findings:
In this work, we present our experience on the use of PBRT technique in SCC treatment. A larger sample of patients is needed to draw conclusions about the impact of this treatment on disease recurrence and overall survival.
Microcomputers play an increasingly important role in the delivery of radiation therapy. Exposure to neutron irradiation can produce undesirable effects in modern microcomputers. The objective of this study is to measure acute and cumulative effects of neutron exposure of Intel-based microcomputers in photon and proton therapy treatment environments.
Materials and methods:
Multiple computers were irradiated with neutrons produced from MEVION S250 passive scattering proton therapy and from Varian 21EX Linear Accelerator photon therapy systems. The energy of the proton beam was 232 MeV and the photon beam energies were 6 and 18 MV. Rates of fatal errors in computer processing unit (CPU) cores were measured.
Results:
Varying rates of fatal system errors due to upsets in the CPU cores were observed. Post-exposure routine stress testing revealed no permanent hardware defects in the random access memory (RAM) or hard disk drive (HDD) of any tested systems. Microchip manufacturers fit increasingly high numbers of transistors in the same volume and the susceptibility to radiation thus increases.
Conclusions:
This work explores if the process size of a microchip is the dominant factor and also looked at the short- and long-term effects of neutron irradiation on modern microprocessors in a clinical environment. Additionally, methods of effective shielding are proposed.
In many countries, there is a skills gap in proton therapy with many staff unprepared to work with the new technology. The new Virtual Environment for Radiotherapy Training (VERT) proton module provides learners with a simulated proton machine 3D environment. This project aimed to evaluate the role of VERT in training the radiotherapy workforce for the future use of protons.
Methods:
A practical teaching session using VERT was deployed after a traditional teaching session had provided basic knowledge. A questionnaire deployed before and after VERT enabled comparison of knowledge while a combination of Likert and open questions gathered participant feedback concerning the initiative.
Results:
A total of 38 students provided evaluation of the session. Overall, there were high levels of satisfaction and enjoyment with 35 participants reporting enjoyment and 36 indicating that the event be repeated.
Discussion:
Participants felt that they had learned from the experience, although quantitative data lacked statistical significance to demonstrate this. All participants agreed that VERT had provided improved understanding of proton dose deposition arising from visualisation of beams and dose deposition. Most participants agreed that the simulation was realistic and that it had improved their understanding. Feedback in relation to future sessions concerned smaller group sizes, more patient cases, more time and additional clinical datasets.
Conclusion:
A proton simulation module has been shown to be an enjoyable teaching tool that improves students’ confidence in their knowledge of the underpinning theory and clinical usage of the modality. Learners felt better prepared to encounter protons in clinical practice. Future work will build on these findings using smaller group work and a more robust assessment tool to identify long-term impact of the training.
In the recent years, some publications (mainly from one group of authors) have dealt with the effectiveness of proton–boron fusion therapy (PBFT). This theory is based on the Q-value of three produced α particles in the reaction of protons with boron (11B). They claim that this reaction significantly increases the absorbed dose in the target volume. However, the current study would re-evaluate their method to show if PBFT is really effective.
Methods and materials:
A parallel 80-MeV proton beam was irradiated on a water medium in a cubic boron uptake region (BUR). The two-dimensional dose distribution and percentage depth dose of protons, alphas and all particles were calculated using tally F6 and mesh-tallies by Monte Carlo N Particle Transport code.
Results:
The results not only showed that the dose enhancement in BUR is neglectable but also the higher density of BUR in comparison with water led to decrement of dose in this region. Because of low cross section of boron for proton beam (<100 mb), the α particles’ dose is 1,000 times lower than the proton dose.
Conclusions:
The physical aspects and the simulation results did not show any effectiveness of the PBFT for proton therapy dose enhancement.
This exploration is intended to analyse the dosimetric characteristics of proton beams of multiple energies using different snout sizes.
Materials and methods
A synchrotron was used for the extraction of eight proton beam energies (100–250 MeV). Dosimetric measurements were taken in a water phantom that was irradiated with a proton beam emanating from the gantry system at angles 0, 90, 180 and 270 degree using a large and a medium snout. The range of beam energies in the phantom, their corresponding centre modulation depth (CMD) and the width of spread out Bragg peak (SOBP) were measured by Markus chamber. Double scattering technique was employed for the creation of SOBPs.
Results
The range of proton beams varied from 4·3 cm for 100 MeV beam to 28·5 cm for 250 MeV beam with the medium snout and from 4·3 cm for 100 MeV to 25 cm for 250 MeV beam with large snout in the water phantom. SOBP width showed a variation from 4 to 10 cm with medium and large snout. While determining the output with medium snout, the discrepancy of 1·1% was observed between the maximum and minimum mean values of output for all the given set of energies and angles. There occurred a difference of 0·9% between the maximum and minimum mean values of output with the large snout. Beam output at SOBP centre was 12% higher with large snout as compared to that with medium snout for all the given beam energies. Flatness and symmetry were found within ±2·5% tolerance limits with medium and large snouts.
Conclusion
Flatness and symmetry were found within explicit limits with both medium and large snouts. Large snout produced higher beam output than that of medium snout at the centre of SOBP. This exploration can be extended to the determination of beam output, flatness and symmetry with a small snout.
Craniospinal irradiation is a technique indicated when a patient has a malignancy that has either disseminated, or is at risk of disseminating, throughout the subarachnoid space. While the craniospinal axis is treatable with conventional radiotherapy, the high doses to organs at risk carry an increased risk of acute and late side effects. Proton craniospinal irradiation is an expensive technique that shows great theoretical promise arising from reduced exit doses. The purpose of this systematic review is to determine the potential role of proton therapy as a standard modality for craniospinal irradiation.
Materials and methods
A literature review was performed to determine the efficacy and cost of proton craniospinal irradiation. The Cochrane Library and the Inspec, Medline (via Pubmed) and Scopus databases were searched. After exclusion criteria were applied, the remaining papers were systematically appraised utilising the Scottish Intercollegiate Guidelines Network critical appraisal checklists.
Results
A total of 14 articles remained following the application of the screening and critical appraisal processes. In total, five of the articles concluded that the risk of secondary malignancy was lower with proton therapy, while ten of the articles included data showing that toxicity rates and organs at risk doses were lower with proton therapy. Doses to most thoracic and abdominal organs at risk analysed in the literature were reduced when proton therapy was used, with the sole exception of the oesophagus, the dose to which depended on whether or not the entire vertebral body was treated. Proton therapy also delivered optimal doses to organs at risk in the head and neck compared with conformal radiation therapy. However, in one study that compared tomotherapy to proton therapy, tomotherapy outperformed proton therapy by delivering lower doses to organs at risk in the head and neck, as well as the kidneys. The two cost-effectiveness studies did not indicate proton therapy as an optimal modality for all treatment sites; however, one of the studies found that for medulloblastoma, protons were more cost effective than conventional radiation therapy.
Findings
Proton therapy is a superior treatment option for craniospinal irradiation. The reduction in risk of toxicity and radiocarcinogenesis offered by proton craniospinal irradiation appear to outweigh the increased costs.
In recent years, there has been a spectacular development in nanomedicine field with new nanoparticles for diagnosis and cancer therapy. Although most researchers have been always interested in gold nanoparticles (GNPs)
Materials and methods
In the present work we present a comparison between the use of bio-nanomaterials in proton therapy.
Conclusion
Consequently, our results show that platinum nanoparticles (PtNPs) present an interesting advantages comparing with GNPs and silver nanoparticles. On the other hand, the use of PtNPs facilitates in a considerable way the proton therapy.
The purpose of this study is to investigate the feasibility of proton arc therapy (PAT) using the double-scattering MEVION-S250 proton system. The treatment planning and dose delivery parameters from PAT were compared with conventional treatment planning techniques.
Materials and methods:
PAT was simulated with multiple conformal and fixed-aperture beams (5–15) using the MEVION-S250-double-scattering proton system. Conformal apertures were simulated with the Eclipse-treatment-planning system: (a) using a static single aperture that provides the best average conformal circular or rectangular apertures to cover the tumour from different angular views (SPAT), and (b) dynamic conformal apertures of the tumour shape at each irradiation angle that can be obtained from a multi-leaf-collimator system (DPAT).
Results:
The DPAT and SPAT plans provided superior dose coverage and sparing of normal tissues in comparison with conventional plans (CPT). The entrance normal tissue and skin doses (<40%) were lowered significantly by delivering dose from different directions over a wider angular view compared to conventional plans that have large entrance dose from only two fields. While the mean and minimum doses from PAT and CPT were comparable, the maximum doses from arc plans were lower than the maximum doses in conventional plans. The SPAT and DPAT plans had comparable dose parameters for regularly shaped targets. The heterogeneity index (HI) was superior in PAT plans which improved with increasing number of beams in arc plans for the different treatment sites. The conformality index (CI) depends on the treatment site and complexity of the shape of the planning target volume where for brain, pancreatic and lung tumours, PAT plans conformality was comparable and sometimes superior to CPT; and HI and CI were generally better in DPAT compared to SPAT.
Conclusions:
PAT plans have superior dose coverage and sparing of normal tissues compared to CPT plans using the MEVION double-scattering system as shown in this simulation study. Ideally, conformal proton arcs require beam shaping and dose delivery with the gantry moving; however, the MEVION double-scattering system lacks a multi-leaf collimator system and cannot deliver dose during gantry rotation. The single aperture conformal proton therapy technique is more time and cost effective compared with conventional techniques that are used currently with the MEVION proton therapy system because of the elimination of the need for patient-specific compensators. In present study, PAT was simulated with the MEVION double-scattering proton therapy system; however, it can be performed also with other proton therapy systems.
This technical note describes a quantitative assessment of the production of radioactive materials during a year-long clinical operation of a Mevion S250i Hyperscan proton therapy system. The production of accumulated radioactive materials plays an important role in determining radiation safety in and around the proton therapy facilities.
Methods:
We have conducted a weekly room survey, every week for a year, during normal clinical operation.
Results and conclusions:
We estimated the accumulated activity from secondary neutron activation on aluminium structures at 3 m away from isocentre in the beamline to be less than 300 μCi.