We partner with a secure submission system to handle manuscript submissions.
Please note:
You will need an account for the submission system, which is separate to your Cambridge Core account. For login and submission support, please visit the
submission and support pages.
Please review this journal's author instructions, particularly the
preparing your materials
page, before submitting your manuscript.
Click Proceed to submission system to continue to our partner's website.
To save this undefined to your undefined account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you used this feature, you will be asked to authorise Cambridge Core to connect with your undefined account.
Find out more about saving content to .
To send this article to your Kindle, first ensure no-reply@cambridge.org is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about sending to your Kindle.
Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
To compare the image-based three-dimensional treatment planning using AcurosTM BV and AAPM TG-43 algorithm for intracavitary brachytherapy of carcinoma cervix.
Materials and methods
Twenty-seven patients with cancer cervix, stage IIB or IIIB with vaginal involvement limited to the upper third of the vagina was included into the study. Intracavitary treatments with the patient in this study done with computed tomography and magnetic resonance imaging compatible ring applicator. Groupe European de Curietherapie and European Society for Therapeutic Radiology and Oncology recommended doses to target volumes and organs at risk compared using dose volume histogram.
Results
The mean value of Point ‘A’ dose was compared between AcurosTM BV and TG-43, which indicates 0·13% difference. The differences in the mean dose to gross tumour volume for various volumes are V100% 0·28%, V150% 1·22% and V200% 1·03%; all volumes showed small difference but statistical significant (p<0·05). The mean dose of high-risk clinical target volume (HRCTV) D90 using AcurosTM BV was 8·47 Gy, which was 1·63% less compared with TG-43. The mean point A dose using AcurosTM BV is 1·04 times the dose to D90 of mean HRCTV. The same difference was observed in comparison with TG43. D2cc and D0·1cc of the bladder, rectum and sigmoid showed a statistically significant difference (p<0·05) in comparison with TG-43.
Conclusion
The differences in dosimetric parameters between the AcurosTM BV and TG-43 proved to be statistically significant. The difference is very small, and they are clinically insignificant.
To compare intensity-modulated radiation therapy (IMRT) treatment planning between using positron emission tomography/computed tomography (PET/CT) and CT for target volume delineation in patients with non-small cell lung cancer (NSCLC).
Methods
Nine NSCLC patients with PET/CT images were enrolled into this study. Gross tumour volumes (GTVs) were delineated by the PET visual assessment (PETvis), the automated PET (PETauto), standardised uptake value (SUV)>2·5 (PET2·5) and threshold 40% SUVmax (PET40), and CT-based method. For each patient, two IMRT treatment plans based on CT and PET/CT delineation were performed. The target coverage and the dose–volume parameters for organs at risk were analysed.
Results
The PETauto referred to PET40 when SUVmax<7 and PET2·5 when SUVmax≥7. The mean GTVs were 15·04, 15·7 and 15·14 cc for PETauto, PETvis and CT based, respectively. The GTV of PETauto was not different from PETvis (p=0·441) and CT based (p=0·594). Based on CT delineation in IMRT planning, only 34% of the cases had sufficient PET/CT planning target volumes coverage, whereas the organs at risk dose parameters were not statistically significant (p>0·05).
Conclusions
PET/CT enables more accurate assessment of tumour delineation for NSCLC, therefore improve target coverage in IMRT plan.
Treatment tabletops are usually made of carbon fibre due to its high mechanical strength and rigidity, low specific density, extremely light and regularly considered radiotranslucent. Our clinic acquired a Calypso 4D Localization System where electromagnetic (EM) frequencies to detect implanted transponders in the patient are used. Carbon fibre is an electrical conductive material which interferes with EM frequencies. Therefore, in order to be able to use the Calypso System the carbon fibre tabletop in the treatment room must be replaced. It is our goal to determine the attenuation of the new, non-carbon fibre, tabletop in treatment delivery.
Materials and Methods
Measurements were performed using an ionisation chamber inserted in a slab phantom positioned at the isocenter for 6, 10 MV, 6 and 10flattening filter free (FFF) MV photon beams. These measurements were performed with and without tabletop for 0°, 30° and 60° beam angle for a True Beam STx linac, for 5×5 cm2 and 10×10 cm2 field size beams. The attenuation was calculated for each measurement for each tabletop.
Results
At 0° incidence on the Exact IGRT Couch, the measured attenuation for 10×10 cm2 was 2·8 and 2·1% for 6 and 10 MV beams, respectively. For the same field size was measured 3·3 and 2·6% attenuation for 6 and 10 FFF MV beams, respectively. At the same incidence and regarding the other tabletops, the calculated attenuation is lower. For 10×10 cm2 field, there is 2·0, 1·4, 2·1 and 2·6% attenuation for 6, 10 MV, 6 and 10 FFF MV energy beams on the kVueTM Universal Couch. For the KvueTM Calypso® Couch 10×10 cm2 irradiation field, the measurements were 1·6, 1·3, 1·9 and 1·5%, respectively. This tendency is observed for all gantry angles.
Discussion
The attenuation outputs were definitely higher for the Varian Exact IGRT Couch when compared with the kVue tabletops. The attenuation measurements for the kVue tabletops were closer to each other. Nevertheless kVueTM Calypso® Varian tabletop showed smaller mean attenuation of the beams than kVueTM Universal Tip Insert for all measurements.
Conclusions
There was no loss in treatment quality administration due to beam attenuation in the tabletop when tabletops were exchanged because of Calypso system integration. There is no need to change between kVue tabletops whenever there is a regular treatment or a Calypso System guided treatment.
The novel three-dimensional (3D) radiotherapy interactive outlining tool allows volumes to be created from a handful of points within axial, sagittal and coronal planes. 3D volumetric visualisation allows users to directly manipulate the resulting volume using innovative-sculpting tools. This paper discusses the development and initial evaluation of the software ahead of formal clinical testing.
Materials and methods
User feedback was collated as part of the software development phase to ensure clinical suitability, define user training strategies and identify best practice. A loosely structured format was adopted with leading descriptive questions aiming to generate suggestions for improvements and initiate further discussion.
Results
The four participants reported great satisfaction and value in being able to use all three planes for outlining, although orientation in 3D was evidently a problem. All participants felt that the software was capable of producing acceptable outlines rapidly and that the multi-planar capability allowed for improved outlining of the prostate apex.
Findings
Mesh generation from a small number of points placed on a range of planes is a rapid and effective means of target delineation. Multi-slice volume sculpting and 3D orientation is challenging and may indicate a need for a paradigm shift in anatomy and computed tomography training.
To determine if a patient’s breast size accurately correlates with the breast volume measured in the computed tomography (CT) scan, and to determine which sizes correspond to a volume >750 cc; in order to predict which patients will benefit from breast irradiation in the prone position.
Methods
Breast size was calculated as the difference between the thoracic (band) and breast (bust) circumferences. Breast volume was contoured by a radiation oncologist and measured on the simulation CT scan. Pearson’s coefficient was used to evaluate the correlation between both variables. A receiver operating characteristic (ROC) analysis was performed to determine the optimal cut-off point to predict which differences between band and bust would be associated with a volume ≥750 cc.
Results
Fifty-nine patients were included in this study. Mean breast volume was 851·8 cc and mean size difference was 4·7 inches. Pearson’s correlation coefficient was 0·61 (p<0·001). The ROC analysis determined that a difference of 5 inches between the band and bust circumferences was the optimal cut-off point to determine a breast volume of 750 cc.
Conclusions
A significant correlation between breast size as measured in the clinical practice and breast volume measured in the CT scan was found. Among other characteristics, a 5-inch difference between breast band and bust will be the cut-off point to decide if a patient will be treated prone at our institution.
We demonstrated that our proposed planning target volume (PTV) dose–volume factor (PDVF) can be used to evaluate the PTV dose coverage between the intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) plans based on 90 prostate patients.
Purpose
PDVF were determined from the prostate IMRT and VMAT plans to compare their variation of PTV dose coverage. Comparisons of the PDVF with other plan evaluation parameters such as D5%, D95%, D99%, Dmean, conformity index (CI), homogeneity index (HI), gradient index (GI) and prostate tumour control probability (TCP) were carried out.
Methods and materials
Prostate IMRT and VMAT plans using the 6 MV photon beams were created from 40 and 50 patients, respectively. Dosimetric indices (CI, HI and GI), dose–volume points (D5%, D95%, D99% and Dmean) and prostate TCP were calculated according to the PTV dose–volume histograms (DVHs) of the plans. All PTV DVH curves were fitted using the Gaussian error function (GEF) model. The PDVF were calculated based on the GEF parameters.
Results
From the PTV DVHs of the prostate IMRT and VMAT plans, the average D99% of the PTV for IMRT and VMAT were 74·1 and 74·5 Gy, respectively. The average prostate TCP were 0·956 and 0·958 for the IMRT and VMAT plans, respectively. The average PDVF of the IMRT and VMAT plans were 0·970 and 0·983, respectively. Although both the IMRT and VMAT plans showed very similar prostate TCP, the dosimetric and radiobiological results of the VMAT technique were slightly better than IMRT.
Conclusion
The calculated PDVF for the prostate IMRT and VMAT plans agreed well with other dosimetric and radiobiological parameters in this study. PDVF was verified as an alternative of evaluation parameter in the quality assurance of prostate treatment planning.
Cone beam computed tomography (CBCT) images contain more scatter than a conventional computed tomography (CT) image and therefore provide inaccurate Hounsfield units (HUs). Consequently, CBCT images cannot be used directly for dose calculation. The aim of this study is to enable dose calculations to be performed with the use of CBCT images taken during radiotherapy and potentially avoid the necessity of re-planning.
Methodology
A phantom and prostate cancer patient with a metallic prosthetic hip replacement were imaged using both CT and CBCT. The multilevel threshold algorithm was used to categorise pixel values in the CBCT images into segments of homogeneous HU. The variation in HU with position in the CBCT images was taken into consideration and the benefit of using a larger number of materials than typically used in previous work has been explored. This segmentation method relies upon the operator dividing the CBCT data into a set of volumes where the variation in the relationship between pixel values and HUs is small. A field-in-field treatment plan was generated from the CT of the phantom. An intensity-modulated radiation therapy plan was generated from CT images of the patient. These plans were then copied to the segmented CBCT datasets with identical settings and the doses were recalculated and compared.
Results
In the phantom study, γ evaluation showed that the percentage of points falling in planning target volume, rectum and bladder with γ<1 (3%/3 mm) was 100%. In the patient study, increasing the number of bins to define the material type from seven materials to eight materials required 50% more operator time to improve the accuracy by 0·01% using pencil beam and collapsed cone and 0·05% when using Monte Carlo algorithms.
Conclusion
The segmentation of CBCT images using the method in this study can be used for dose calculation. For a simple phantom, 2 values of HU were needed to improve dose calculation accuracy. In challenging circumstances such as that of a prostate patient with hip prosthesis, 5 values of HU were found to be needed, giving a reasonable balance between dose accuracy and operator time.
Emotional intelligence (EI) is an increasingly important aspect of a health professional’s skill set. It is strongly associated with empathy, reflection and resilience; all key aspects of radiotherapy practice. Previous work in other disciplines has formed contradictory conclusions concerning development of EI over time. This study aimed to determine the extent to which EI can develop during a radiotherapy undergraduate course and identify factors affecting this.
Methods and materials
This study used anonymous coded Likert-style surveys to gather longitudinal data from radiotherapy students relating to a range of self-perceived EI traits during their 3-year degree. Data were gathered at various points throughout the course from the whole cohort.
Results
A total of 26 students provided data with 14 completing the full series of datasets. There was a 17·2% increase in self-reported EI score with a p-value<0·0001. Social awareness and relationship skills exhibited the greatest increase in scores compared with self-awareness. Variance of scores decreased over time; there was a reduced change in EI for mature students who tended to have higher initial scores. EI increase was most evident immediately after clinical placements.
Conclusions
Radiotherapy students increase their EI scores during a 3-year course. Students reported higher levels of EI immediately after their clinical placement; radiotherapy curricula should seek to maximise on these learning opportunities.
Indeterminate pulmonary nodules incidentally detected during radiological imaging completed for radiotherapy planning always creates dilemma for the oncologist. The purpose of this study is to evaluate the clinical significance of pulmonary nodules incidentally detected in patients undergoing locoregional radiotherapy for breast cancer and present a retrospective analysis of the natural progression of such nodules.
Methods
A retrospective review of computed tomography scans of breast cancer patients who underwent radiotherapy over a period of 3 years to screen out patients with indeterminate lung nodules was undertaken. This was correlated with the patient and tumour characteristics and the status of the disease at last follow-up.
Results
Of the 132 patients reviewed 28 had indeterminate lung nodules. Of the 28 patients, four had progressive lung nodules on follow-up. Subgroup analyses did not show any significant correlation.
Discussion and conclusion
One fifth of patients may present with incidentally detected lung nodules. Multiple nodules, ER negative status and locally advanced breast cancer may point to a higher risk of these nodules progressing to metastatic cancer. There is no indication to stop locoregional therapy in the presence of indeterminate nodules, but close follow-up of high-risk group is recommended.
To review the incidence of clinically significant pulmonary toxicity following total body irradiation (TBI) as a part of the conditioning regimen for acute lymphoblastic leukaemia (ALL) patients undergoing bone marrow transplantation (BMT) at The Ottawa Hospital Cancer Centre.
Methods
This is a retrospective review of ALL patients who received TBI in The Ottawa Hospital Bone Marrow Transplant Program (TOH-BMT) as part of their conditioning regimen from 1991 to 2011 inclusive. The patients were treated using a locally developed translating-couch irradiation technique. We have analysed all available data for the first 100 days following TBI to determine the incidence of radiation-induced pulmonary toxicities.
Results
Of the total 622 patients undergoing TBI during the specified period, 88 had ALL. Median age at BMT was 30 years and the conditioning regimens varied. A total of 74 (84%) patients received 12 Gy/6 F/BID of TBI. A total of 55 (63%) patients have died, 32 (36%) within the 1st year after BMT. In the 1st year, pulmonary events were reported for 24 (27%) patients, and the follow-up notes were unavailable for seven (8%). Pulmonary toxicities were reported as the cause of death for six patients, five (6%) within the 1st year. It is estimated that the total number of deaths in the 1st year possibly attributed to radiation-induced lung injury was four (4·5%). Eight (9%) patients had symptoms suggestive of non-lethal grade 2–3 radiation-induced pneumonitis.
Conclusions
TBI continues to be an important component of the conditioning regimen for ALL patients undergoing BMT, and the incidence of radiation-induced pulmonary injury, using our technique and lung dose, is comparable to the published literature.
The aim of this study was to evaluate the dosimetric aspects of whole brain radiotherapy (WBRT) using an irregular surface compensator (ISC) in contrast to conventional radiotherapy techniques.
Methods
Treatment plans were devised for 20 patients. The Eclipse treatment planning system (Varian Medical Systems) was used for dose calculation. For the ISC, a fluence editor application was used to extend the range of optimal fluence. The treatment plan with the ISC was compared with the conventional technique in terms of doses in the planning target volume (PTV), dose homogeneity index (DHI), three-dimensional (3D) maximum dose, eye and lens doses and monitor unit (MU) counts required for treatment.
Results
Compared with conventional WBRT, the ISC significantly reduced the DHI, 3D maximum dose and volumes receiving 105% of the prescription dose, in addition to reducing both eye and lens doses (p<0·05 for all comparisons). In contrast, MU counts were higher for the ISC technique than for conventional WBRT (828 versus 328, p<0·01).
Conclusion
The ISC technique for WBRT considerably improved the dose homogeneity in the PTV. As patients who receive WBRT have improved survival, the long-term side effects of radiotherapy are highly important.
To explore the impact of breast size on mean lung dose (MLD) for patients receiving breast radiotherapy.
Methodology
Chest wall separation (CWS), volume of tissue receiving 95% isodose and MLD were measured on 80 radiotherapy treatment plans of patients receiving tangential radiotherapy treatment to the whole breast. Breast size was categorised as small (CWS<25 cm and planned target volume (PTV)<1,500 cm3) and large (CWS>25 cm and PTV>1500 cm3). Pearson’s correlation and independent sample t-test were used to analyse data.
Results
MLD was not affected by CWS (r=−0·13, p=0·24) nor volume of tissue receiving 95% isodose (r=−0·08, p=0·49). Significant variation between small and large breasts was noted for CWS (t=8·24, p=0·00) and volume of tissue receiving 95% isodose (t=5·68, p=0·00). No significant variation was noted between small and large breast for MLD (t=−0·26, p=0·80) and between left and right breasts for CWS (t=1·42, p=0·16) and volume of tissue receiving 95% isodose (t=−1·08, p=0·28). Significant difference between left (18–808 cGy) and right breast (325–365 cGy) was demonstrated for MLD (t=3·03, p=0·00).
Conclusion
This study demonstrated lack of correlation between breast size and MLD. Further research is recommended for justification of alternative techniques for this subgroup of patients to provide optimised radiotherapy delivery.
Locally advanced head and neck cancer can be a distressing disease due to a variety of reasons. This retrospective study looks at the tolerability and outcomes for palliative split-course hypofractionated radiotherapy for this group of patients treated in our centre.
Results
A total of 59 patients were treated with hypofractionated split-course radiotherapy for incurable mucosal squamous cell carcinoma of the head and neck region in our centre over a 10-year period. In all, 71% had stage IV disease. Radiotherapy consisted of three phases of 14·4 Gy/phase, in four to eight fractions over 4 days giving one·8–3·6 Gy/fraction. The phases were separated by 2 weeks. A total of 40 patients (63%) completed all three phases. A total of 72% patients had no acute toxicities and the palliation rate was 83% (complete and partial). Only five patients had no meaningful palliation having completed all three phases. Median duration of local control was 6 months (range: 1–63 months) and median overall survival was 8 months (range: 1–68 months). In five patients, the control was durable with no recurrence at the time of analysis with survival ranging from 6 to 57 months.
Conclusion
We are the first UK centre to report with long-term data, the use of a palliative three phase regime that provides meaningful palliation with acceptable toxicities. In addition, for some patients, it has resulted in durable long-term control.
Exposure of skin to high doses of radiation may lead to the development of erythematous skin changes. The aims of this study were to measure skin doses and to identify potential factors that may contribute to skin reactions in nasopharyngeal cancer patients undergoing intensity-modulated radiation therapy (IMRT).
Material and methods
This study was a prospective study with 21 nasopharyngeal cancer patients treated by IMRT. Personal data were collected and in vivo skin dose measurements were performed using Thermoluminescent dosimeters. All patients were monitored clinically and skin reactions were classified according to the Radiation Therapy Oncology Group criteria. Univariate and multivariate logistic regression was conducted using Statistical Package for Social Sciences Software to identify skin toxicity risk factors.
Results
Grade 1 toxicity was observed in eight patients, Grade 2 in 11 patients and Grade 3 in two patients towards the end of treatment. It was found that accumulative skin doses >7 Gy (p<0·05) was a risk factor for skin toxicity. However, previous or concomitant chemotherapy with radiotherapy and stage of cancer were not significant factors for the severity of skin reactions.
Conclusion
The neck skin should be identified as a sensitive structure for dose optimisation. Skin dose measurement and skin-sparing techniques are highly recommended for head and neck patients treated with IMRT.
The aim of this study is the dosimetric verification and comparative analysis of two different treatment planning systems (TPS) using collapsed cone convolution (CCC) and pencil beam (PB) algorithms for treatment sites of head and neck, chest wall–supraclavicular region, lung and prostate.
Methods and materials
Target volumes and critical organs for treatment sites mentioned above were delineated according to relevant The Radiation Therapy Oncology Group protocols. Treatment plans were generated using 6 MV photon energy with medical linear accelerator and Thermoluminescent Dosimeter-100 dosimeters were used to perform dosimetric verification, which were placed at appropriate locations in the Alderson Rando phantom.
Results and conclusions
Comparative analysis of CCC and PB algorithms for treatment sites revealed that point dose measurement values were higher with the PB algorithm compared with CCC algorithm, in both head and neck and chest wall–supraclavicular region plans. The most significant difference between two algorithms were found at the supraclavicular region which includes the lung point dose within the treatment field and 7–12 mm depth from the skin, respectively. Unlike the head and neck and chest wall–supraclavicular region plans, CCC and PB algorithms show overall comparable results in lung and prostate plans in terms of point dose measurement values; however, the most prominent difference was found in 7 mm and 6 cm depth from skin, respectively. The CCC algorithm values were higher. Our study confirms that the main reason of PB algorithm calculates less absorbed dose than CCC algorithm in medium transitions, skin entrance and irregular treatment regions is the underestimation of lateral equilibrium’s contribution to the total absorbed dose.
Merkel cell carcinoma is a rare and aggressive primary cutaneous neuroendocrine carcinoma with a high risk of loco-regional and distant metastasis. It is predominantly seen in the elderly, on the head and neck or extremities. Although treated primarily with surgery, some patients are too frail. A World Health Organization performance status of two or more with co-existing medical co-morbidities, or the site of the disease adjacent to a critical structure, can prevent surgical management. In this cohort of patients, primary palliative radiotherapy has been found to achieve excellent tumour regression and improve quality of life. A new palliative split-course hypofractionated regime has been used in North Middlesex University Hospital in this cohort of patients. The purpose of this case series was to provide supporting evidence on the efficacy of this dose and fractionation regime and review the literature for the palliative management of Merkel cell carcinoma.
Materials and methods
In total, four patients were treated with the palliative split-course hypofractionated regime. The regime consisted of an initial 20 Gray in 5 fractions over 1 week, a 2-week gap and then a further 20 Gray in 5 fractions over 1 week. Tolerability and response to treatment were evaluated by history and clinical examination.
Results and conclusion
The split-course hypofractionated regime was well tolerated, achieved excellent tumour regression and improved quality of life in all four patients. Since then, a further three patients have been successfully treated with the above regime. This case series demonstrates the efficacy of this dose and fractionation in a select group of patients too frail for radical management and adds to the evidence base for the optimal palliative management of Merkel cell carcinoma.
Intraoperative radiotherapy is a method of choice to deliver a critical radiation dose to the tumour bed immediately after surgical excision.
Aim
The purpose of this work is to check the dose delivered to the patients during intraoperative electron beam radiation therapy (IOERT) in the conservative treatment of breast cancer, by means of reference dose measurement using radiochromic (EBT-2) films.
Material and methods
Ninety patients with early-stage breast cancer underwent exclusive IOERT to the tumour bed using a LIAC linear accelerator. Absolute dose measurements were done with film pieces. After irradiation, the pixel values of the films were obtained via MATLAB and ImageJ softwares. Calibration curve was also used for calculating net optical density. Expected dose was compared to the patient delivered dose.
Results
The mean deviation of the delivered dose from the expected one was 2·56% that is well in the accepted criteria. Only in one case, there was a larger deviation due to barometer miscalibration.
Findings
EBT-2 film response is independent from dose-per-pulse and as it was shown in this study it can be robustly used during breast IOERT for dosimetric and also positioning verifications.
This study evaluated dosimetric parameters for cervical high-dose-rate (HDR) brachytherapy treatment using varying dose prescription methods.
Methods
This study includes 125 tandem-based cervical HDR brachytherapy treatment plans of 25 patients who received HDR brachytherapy. Delineation of high-risk clinical target volumes (HR-CTVs) and organ at risk were done on original computed tomographic images. The dose prescription point was defined as per International Commission in Radiation Units and Measurements Report Number 38 (ICRU-38), also redefined using American Brachytherapy Society (ABS) 2011 criteria. The coverage index (V100) for each HR-CTV was calculated using dose volume histogram parameters. A plot between HR-CTV and V100 was plotted using the best-fit linear regression line (least-square fit analysis).
Results
Mean prescribed dose to ICRU-38 Point A was 590·47±28·65 cGy, and to ABS Point A was 593·35±30·42 cGy. There was no statistically significant difference between planned ICRU-38 and calculated ABS Point A doses (p=0·23). The plot between HR-CTV and V100 is well defined by the best-fit linear regression line with a correlation coefficient of 0·9519.
Conclusion
For cervical HDR brachytherapy, dose prescription to an arbitrarily defined point (e.g., Point A) does not provide consistent coverage of HR-CTV. The difference in coverage between two dose prescription approaches increases with increasing CTV. Our ongoing work evaluates the dosimetric consequences of volumetric dose prescription approaches for these patients.
Craniospinal irradiation is a technique indicated when a patient has a malignancy that has either disseminated, or is at risk of disseminating, throughout the subarachnoid space. While the craniospinal axis is treatable with conventional radiotherapy, the high doses to organs at risk carry an increased risk of acute and late side effects. Proton craniospinal irradiation is an expensive technique that shows great theoretical promise arising from reduced exit doses. The purpose of this systematic review is to determine the potential role of proton therapy as a standard modality for craniospinal irradiation.
Materials and methods
A literature review was performed to determine the efficacy and cost of proton craniospinal irradiation. The Cochrane Library and the Inspec, Medline (via Pubmed) and Scopus databases were searched. After exclusion criteria were applied, the remaining papers were systematically appraised utilising the Scottish Intercollegiate Guidelines Network critical appraisal checklists.
Results
A total of 14 articles remained following the application of the screening and critical appraisal processes. In total, five of the articles concluded that the risk of secondary malignancy was lower with proton therapy, while ten of the articles included data showing that toxicity rates and organs at risk doses were lower with proton therapy. Doses to most thoracic and abdominal organs at risk analysed in the literature were reduced when proton therapy was used, with the sole exception of the oesophagus, the dose to which depended on whether or not the entire vertebral body was treated. Proton therapy also delivered optimal doses to organs at risk in the head and neck compared with conformal radiation therapy. However, in one study that compared tomotherapy to proton therapy, tomotherapy outperformed proton therapy by delivering lower doses to organs at risk in the head and neck, as well as the kidneys. The two cost-effectiveness studies did not indicate proton therapy as an optimal modality for all treatment sites; however, one of the studies found that for medulloblastoma, protons were more cost effective than conventional radiation therapy.
Findings
Proton therapy is a superior treatment option for craniospinal irradiation. The reduction in risk of toxicity and radiocarcinogenesis offered by proton craniospinal irradiation appear to outweigh the increased costs.