We partner with a secure submission system to handle manuscript submissions.
Please note:
You will need an account for the submission system, which is separate to your Cambridge Core account. For login and submission support, please visit the
submission and support pages.
Please review this journal's author instructions, particularly the
preparing your materials
page, before submitting your manuscript.
Click Proceed to submission system to continue to our partner's website.
To save this undefined to your undefined account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you used this feature, you will be asked to authorise Cambridge Core to connect with your undefined account.
Find out more about saving content to .
To send this article to your Kindle, first ensure no-reply@cambridge.org is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about sending to your Kindle.
Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
The purpose of the study was to evaluate the impact of changes in breathing pattern inside the breath-hold window (BHW) during deep inspiration breath hold treatment for carcinoma left breast patients post-conservative surgery.
Methods:
Ten patients of carcinoma left breast post-conservative surgery were prospectively selected. Three sets of CT plain images were acquired, one with 5 mm deep inspiration BHW (DIBHR) and the other one with 1 mm BHW matching the lower threshold (DIBHL) and the third one with 1 mm BHW matching the upper threshold (DIBHH) as DIBHR. For all patients, forward intensity-modulated radiotherapy (FIMRT) and volumetric modulated arc therapy (VMAT) plans were generated in the 5 mm BHW CT series and the same plan being copy and pasted in other series. Target volume doses and critical structure doses were tabulated.
Results:
Planning target volume coverage was adequate and no significant differences were found in any CT series. Significant differences noted in average left lung V5%, V10% and V18% doses between DIBHR versus DIBHH (p values = 0·0461, 0·0283 and 0·0213, respectively) and DIBHL versus DIBHH (p values = 0·0434, 0·0484 and 0·0334, respectively) for FIMRT plans and V18% doses in DIBHR versus DIBHH (p = 0·0067) in VMAT. No differences in heart and apex of heart doses were found. Left anterior descending artery (LAD) mean doses were significant in DIBHL versus DIBHR, DIBHR versus DIBHH and DIBHL versus DIBHH (p = 0·0012, 0·0444 and 0·0048, respectively) series for FIMRT plans and DIBHR versus DIBHH and DIBHL versus DIBHH (p = 0·0341, 0·0001) for VMAT plans.
Finding:
The changes in the breathing pattern inside DIBH window level cause some variation in LAD doses and no other significant differences in any parameters noted, so care should be taken while treating patients with preexisting cardiac conditions.
To investigate the modalities of tumour bed (TB) localisation of target volume delineation [clinically computed tomography (CT), ultrasound (US) compared with surgical clips-guided] and the impact of their differences in delineated TB volumes.
Material and methods
In total, 27 patients who underwent oncoplastic breast conservative surgery with surgical clips insertion (at least three) were included. CT and US imaging for TB localisation were done 3–4 weeks post-operatively in the same treatment position. TB was delineated four times, guided by surgical clips, clinical data, CT (seroma) and US. A plan was done for each TB delineated. The four delineated volumes were compared regarding the volumetric differences, the geographical miss index (GMI) and the overlap index.
Results
Comparing the four modalities, median TB volume was for clinical (60.7), CT (60.8) and US (49.3) cm3, in comparison with 59.7 cm3 for clips, p=0.05. Median of GMI (represented the tissue at risk of recurrence and not had been treated) was for clinical (61.8), CT (45) and US (62.4)%, with significant difference of p=0.02. Median of normal tissue index (normal tissue has been included unnecessarily) was for clinical (59.5), CT (49.6) and US (62.3)%, p=0.17. Overlap index with clips-guided was for clinical (0.36), CT (0.42) and US (0.35) with significance of p=0.04. Median superior/inferior direction was 0.72, −0.03 and −0.2 cm for clinical, CT and US, respectively, with significant value of p=0.02, whereas the anterior–posterior was −0.07, −0.15 and −0.09 cm, p-value=0.45 and the medio–lateral was 0.4, −0.13 and 0.09 cm, p=0.60.
Conclusion
Significant differences in shifts and indices were detected between each of modalities compared with surgical clips. Thus, in the setting of oncoplastic breast surgery, surgical clips should be routinely used for TB localisation. In view of the larger volumes of breast tissue excised and the extensive remodelling that are inherent to oncoplastic procedures, the concept of TB boost irradiation should be re-challenged.
To evaluate clinically pertinent skin dose and volume parameters for the development of toxicities following accelerated partial breast irradiation (APBI).
Methods:
Three skin structures of various thicknesses inside the body (2 mm, 3 mm, 4 mm) were contoured over the treated breast retrospectively in a cohort of 62 women who underwent APBI using multi-catheter interstitial brachytherapy. The correlation statistics between the various skin structures and acute and late skin sequelae were evaluated using the Mann–Whitney U test and receiver-operating characteristic analysis. A p-value of <0·05 was considered significant.
Results:
At a median follow-up period of 54 months (range: 28–86), a significant correlation was seen between dose received by 0·2 (D0·2) cc of skin 4 mm inside the body as well as volume receiving 100% dose (V100) of skin 3 mm inside the body with cosmesis at 2 years and at last follow-up. The threshold for the two parameters for prediction of excellent or good cosmesis was 90% of the prescribed dose and 0·05 cc, respectively. No significant dosimetric or volumetric correlation was seen with other sequelae like wound dehiscence, fat necrosis, telangiectasia and atrophy.
Conclusion:
The results of this study support the use of dose and volumetric indices of the sub-volumes of the skin for correlation with clinical endpoints. However, the same should be validated prospectively in a larger cohort of women undergoing breast brachytherapy.
Whole-breast external beam radiotherapy results in significant reduction in the risk for breast cancer-related death, but this may be offset by an increase in deaths from other causes and toxicity to surrounding organs. Partial breast irradiation techniques are approaches that treat only the lumpectomy area rather than the whole breast. Quality assurance in the radiation therapy treatment planning process is essential to ensure accurate dose delivery to the patient. For this purpose, this article compares the results from an anthropomorphic PRESAGE® dosimeter, radiation treatment planning system and from the GAFCHROMIC® EBT2 film.
Materials and methods
A breast dosimeter was created and a three-field partial plan was generated in the Pinnacle3 treatment planning system. Dose distribution comparisons were made between Pinnacle3 treatment planning system, GAFCHROMIC® EBT2 film and PRESAGE® dosimeter. Dose–volume histograms (DVHs), gamma maps and line profiles were used to evaluate the comparison.
Results
DVHs of gross tumour volume, clinical tumour volume and planning tumour volume for the PRESAGE® dosimeter and Pinnacle3 treatment planning system shows that both measured and calculated statistics were in agreement, with a value of 97.8% of the prescribed dose. Gamma map comparisons showed that all three distributions passed 95% at the ±3%/±3 mm criteria. Comparisons of isodose line distribution between the PRESAGE® dosimeter, EBT2 film and planning system demonstrated agreement, with an average difference of 1.5%.
Conclusions
This work demonstrated the feasibility of PRESAGE® to function as an anthropomorphic phantom and laid the foundation for research studies in PRESAGE®/optical-computed tomography three-dimensional dosimetry with the most complex anthropomorphic phantoms.
Breast intraoperative radiotherapy (IORT) is a partial irradiation technique that delivers a single fraction of radiation dose to the tumour bed during surgery. The use of this technique is increasing (especially in the Middle East), and therefore, it is essential to have a comprehensive approach to this treatment modality. The aim of this study is to conduct a literature review on available IORT modalities during breast irradiation as well as dedicated IORT machines and associated treatment procedures. The main IORT trials and corresponding clinical outcomes are also studied.
Materials and Methods
A computerised search was performed through MEDLINE, PubMed, PubMed Central, ISI web of knowledge and reference list of related articles.
Results
IORT is now feasible through using two main modalities, including low-kilovolt IORT and intraoperative electron radiotherapy (IOERT). The dedicated machines employed and treatment procedure for mentioned modalities are quite different. The outcomes of implemented clinical trials showed that IORT is not inferior to external beam radiotherapy (EBRT) in specifically selected and well-informed patients and can be considered as an alternative to EBRT.
Conclusion
Although the clinical outcomes of introduced IORT methods are comparable, but based on the review results, it could be said that IOERT is the most effective technical method, in view of the treatment time and dose uniformity concepts. The popularity of IORT is mainly due to the distinguished obtained results during breast cancer treatment. Despite the presence of some technical challenges, it is expected that the IORT technique will become more widespread in the immediate future.
The management of breast cancer patients from diagnosis to treatment and beyond can be variable depending on factors including tumour extent and location, histology, genetics, health and wellbeing of the patient as well as personal patient preferences. The therapeutic radiographer’s role is not only vital to ensure safe and accurate radiotherapy delivery but also crucially, as the regular patient interface, they must be fully empowered to engage effectively with all aspects of the patient care pathway. They must be knowledgeable and up to date with evidence-based practices relating to the patient experience including surgery, chemotherapy, endocrine therapy and radiotherapy.
Aim:
The aim of this paper is to outline the breast cancer management pathway, highlighting the potential side effects that occur as a result of breast radiotherapy treatment and concomitant treatment in order to inform therapeutic radiographers and best practice.
Discussion:
The treatment pathway for breast cancer patients varies greatly depending on a wide range of factors and is very much individualised for each patient. Each treatment modality has its advantages and disadvantages, and all come with a number of side effects that can affect a patient’s daily living. Toxicities can arise during radiotherapy treatment or months after treatment, and education regarding the management of these is essential for effective patient care. Many technological advances in radiotherapy treatment techniques and regimes have the potential to decrease radiation-induced side effects. Despite attempts to standardise clinical guidelines on the use of topical agents and dressings, historical opinions and ideas are still evident in clinical practice. The use of grading systems in radiotherapy tends to only record patients’ physical symptoms and not their holistic wellbeing and emotional needs.
Conclusion:
Therapeutic radiographers must ensure that they remain equipped with the skills and knowledge to correctly manage and/or signpost services effectively. This overall outline of the management of patients with breast cancer is designed to help therapeutic radiographers reflect on the current practices and to inspire them, where evidence dictates, to seize opportunities, to explore improvement and to enhance best practice.
This study aimed to determine the suitable breast treatment technique for a small facility’s hospital with limited staff and equipment resources. The benefits and drawbacks of each technique should be considered to guide radiation oncologists choose the appropriate treatment option for postmastectomy radiation therapy (PMRT) patients.
Methods and Materials:
This study included the computed tomography images of 15 patients who received left-sided PMRT. The patient’s characteristics were classified into two groups: 1. irradiation of only the chest wall (CW) and 2. CW lymph nodes plus supraclavicular lymph nodes (SPCs). All 15 PMRT patients were generated in 4 treatment techniques including 3DCRT, field-in-field (FiF), intensity-modulated radiotherapy (IMRT) and hybrid (3DCRT + IMRT). Each treatment technique’s dosimetric parameters and treatment time were compared.
Result:
All four treatment plans met the acceptable criteria. The IMRT plans achieved the highest plan quality scores for two groups of PMRT patients but require the longest treatment time, whereas the 3DCRT and FiF plans demonstrated superiority for organ at risk (OAR) sparing and required the shortest treatment time when compared with the IMRT and hybrid plans.
Conclusion:
The IMRT plan had the highest plan quality but required the most time to treat. Treatment times are critical in facilities with limited resources. As a result, the FiF plan was found to be a suitable technique for both CW-only and CW plus SPC irradiation due to its short treatment time and high plan quality scores for OAR dose sparing.
An in-house self-held respiration monitoring device (SHRMD) was developed for providing deep inspiration breath hold (DIBH) radiotherapy. The use of SHRMD is evaluated in terms of reproducibility, stability and heart dose reduction.
Methods and materials:
Sixteen patients receiving radiotherapy of left breast cancer were planned for treatment with both a free breathing (FB) scan and a DIBH scan. Both FB and DIBH plans were generated for comparison of the heart, left anterior descending (LAD) artery and lung dose. All patients received their treatments with DIBH using SHRMD. Megavoltage cine images were acquired during treatments for evaluating the reproducibility and stability of treatment position using SHRMD.
Results:
Compared with FB plans, the maximum dose to the heart by DIBH technique with SHRMD was reduced by 29·9 ± 15·6%; and the maximum dose of the LAD artery was reduced by 41·6 ± 18·3%. The inter-fractional overall mean error was 0·01 cm and the intra-fractional overall mean error was 0·04 cm.
Conclusion:
This study demonstrated the potential benefits of using the SHRMD for DIBH to reduce the heart and LAD dose. The patients were able to perform stable and reproducible DIBHs.
To investigate the dosimetric advantage of quasi-continuous couch motion-enabled trajectory modulated arc radiotherapy therapy (TMAT) over the coplanar tangential partial arcs volumetric modulated arc radiotherapy (VMAT) for treating left breast and chest wall patients.
Method
Treatment plans of 43 patients who received radiotherapy for left breast (17) or for left chest wall (26) using coplanar partial tangential arcs VMAT (reference plan) were considered for this study. For each patient, in addition to the treatment plan, a TMAT plan was also generated using quasi-continuous couch rotation. The TMAT plan consisted of original two 30° tangential arc beams and two supplementary beams having a couch rotation of ±10°, ±20° and ±30°, respectively. The difference in PTV volume coverage (PTV V95%) between TMAT plan and VMAT plan was calculated for all the cases and normalised to the plan’s prescription dose. Similarly, differences in PTV_V105% and several dose-volume parameters related to organs at risk (OAR) were also computed and tabulated.
Result
TMAT shows an increment in the PTV dose coverage V95% with respect to reference plan by 4·7±2·5% when averaged overall prescription dose levels. Mean PTV dose (averaged overall prescription levels) for reference and TMAT plan was 4638·6±423·8 and 4793·5±447·2 cGy, respectively, and statistically insignificant (p=0·06). However mean PTV_V105% values for TMAT and for reference plans were 6·7±4·8 and 7·2±5·2%, respectively, and were not statistically different (p=0·85). Mean heart dose in TMAT was less than in VMAT plans, but not significantly. As regarding D1% to heart, TMAT plan was again found to be better with a mean difference of 137·1 cGy over VMAT plan. Other parameters evaluated were: mean dose and D1% to contralateral breast, and V20 Gy and V5 Gy for lung.
Conclusion
TMAT plans were found to be better than VMAT plans in terms of PTV coverage and D1% for heart. For evaluated dose parameters apart from PTV coverage and D1% to the heart, no significant differences were observed. Thus, TMAT plans yielded better dose distribution in terms of PTV dose coverage, hot spots and OAR doses.
Bullous pemphigoid (BP) is the most common autoimmune bullous disease, which is usually seen in older ages. Rarely, radiotherapy (RT) has been reported as a localised trigger factor for BP.
Case:
We present a case of a 64-year-old woman who underwent radical mastectomy and radiation therapy for breast cancer. Two months after the completion of RT with adjuvant Trastuzumab, a BP eruption developed in the irradiated area, spreading thereafter to other skin areas. The patient was treated with oral corticosteroids and the lesions evolved favourably.
Conclusion:
This case demonstrates a relatively benign skin reaction that could develop during the course of cancer treatment, which required co-management by oncologists, pathologists and dermatologists.
Evaluating the improvements of placing the treatment isocentre at the boost centre of mass (CoM) in a hybrid treatment for breast cancer radiotherapy.
Material and methods:
Twenty-two patients were planned in two isocentre locations with two forward intensity-modulated radiation therapy (fIMRT) tangentials to the breast and a volumetric-modulated arc therapy (VMAT) to the boost. A simultaneous integrated boost technique was used. Breast Boost (BB) Vector was investigated as a criterion for selecting an appropriate isocentre placement. Various metrics for boost, breast and hybrid plans were analysed using analysis of variance statistics.
Results:
Comparing hybrid plans at the boost CoM vs. hybrid plans at the breast CoM, no significant differences were found. Analysis of relative variations of planning target volume (PTV) boost coverage vs. BB Vector indicated an upgrade in boost CoM isocentre strategy. Dose to organs at risk was comparable: V5Gy (26·24 vs. 25·69%, p = 0·8), V20Gy (14·66 vs. 14·58%, p = 0·959) and the mean dose (7·37 Gy vs. 7·26 Gy, p = 0·879) to ipsilateral lung; V5Gy (15·60 vs. 15·22%, p = 0·903), and the mean dose (4·91 Gy vs. 4·86 Gy, p = 0·950) to heart and dose to free breast of boost (46·71 Gy vs. 46·62 Gy, p = 0·408).
Findings:
The hybrid fIMRT–VMAT technique centred at the boost CoM resulted equivalent to plans centred at the breast CoM, while benefiting from an enhancement in PTV boost coverage for patients with BB Vector superior to 5.
To measure and compare the skin doses received by treated left breast and contralateral breast (CB) during whole breast radiotherapy using five treatment techniques in an indigenously prepared wax breast phantom.
Materials and methods:
Computed tomography (CT) images of the breast phantom were used for treatment planning and comparison of skin dose calculated from treatment planning system (TPS) with measured dose. Planning target volume (PTV) and the CB were drawn arbitrarily on the CT images acquired for the breast phantom with 10 numbers of calibrated optically stimulated luminescent dosimeters (OSLDs) fixed on the surface of both breasts. The TPS calculated surface doses of PTV breast and CB for five treatment planning techniques, viz., conventional wedge (CW), irregular surface compensator-based (ISC), field-in-field (FiF), intensity-modulated radiotherapy (IMRT) and rapid arc (RA) techniques were obtained for comparison. The plans were executed in Clinac iX Linear Accelerator with the OSLDs fixed at the same locations on the phantom as in simulation. The TPS calculated mean dose at the surface of the treated left breast and CB was noted for the 10 OSLDs from dose-volume histogram (DVH) and compared with the measured dose. Also, the mean chamber dose at the centre of the left breast was noted from the DVH for comparing with ion chamber measured dose.
Results:
With reference to the results, it is seen that the dose to the CB is lowest in ISC technique and FiF technique and greatest in IMRT technique. The CW technique also delivered a dose comparable to IMRT to the CB of the phantom. The dose to the surface of PTV breast was highest and comparable in CW plans and FiF plans (68% and 67%) and lowest in IMRT and RA plans (50% each).
Findings:
Analysis of the results shows that the FiF and ISC techniques are preferred while planning breast radiotherapy due to the reduced dose to the CB.
During the radiation therapy of tumoral breast, the contralateral breast (CB) will receive scattered doses. In the present study, the photon and thermal neutron dose values received by CB surface during breast cancer radiation therapy were measured.
Materials and methods:
The right breast region of RANDO phantom was considered as CB, and the measurements of photon and thermal neutron dose values were carried out on this region surface. The phantom was irradiated with 18 MV photon beams, and the dose values were measured with thermoluminescent dosimeter (TLD-600 and TLD-700) chips for 11 × 13, 11 × 17 and 11 × 21 cm2 field sizes in the presence of physical and dynamic wedges.
Results:
The total dose values (photon + thermal neutron) received by the CB surface in the presence of physical wedge were 12·06%, 15·75% and 33·40% of the prescribed dose, respectively, for 11 × 13, 11 × 17 and 11 × 21 cm2 field sizes. The corresponding dose values for dynamic wedge were 9·18%, 12·92% and 29·26% of the prescribed dose, respectively. Moreover, the results showed that treatment field size and wedge type affect the received photon and thermal neutron doses at CB surface.
Conclusion:
According to our results, the total dose values received at CB surface during breast cancer radiotherapy with high-energy photon beams are remarkable. In addition, the dose values received at CB surface when using a physical wedge were greater than when using a dynamic wedge, especially for medial tangential fields.
Radiation exposure to the thyroid gland during breast irradiation can lead to hypothyroidism and this can impact on the quality of life. The aim of this study was to analyse if there is any difference in the radiation dose received by the thyroid gland during supraclavicular irradiation for breast cancer, with two different neck positions—straight or when the head is turned to the contralateral side to the breast being treated, when using a conformal technique.
Materials and methods:
All patients who received chest wall/breast and supraclavicular irradiation for breast cancer in 2019 in our department were divided into two groups based on the neck position as SN (neck positioned straight) and TN (neck tilted to contralateral side). The volume of thyroid gland, the radiation dose and volume parameters for Dmax, Dmean, and V5 to V40 of the thyroid were tabulated.
Results:
There were 72 patients included in the study with a mean age of 59 years, with 39 in the SN group and 33 in the TN group. There was no significant difference in thyroid volume between the two groups. Dmean, V15, V20, V25, V30 and V35 were significantly lower in tilted neck patients as compared to straight neck patients.
Conclusion:
Neck positioned to the contralateral side of the breast primary may be recommended for conformal CT-based radiation planning.
The purpose of this study was to investigate whether significant difference exists on radiation dose delivered to organs at risks in megavoltage computed tomography (MVCT) verification using three predefined scanning modes, namely fine (2 mm), normal (4 mm) and coarse (6 mm). This will provide information for the imaging protocol of tomotherapy for the left breast.
Materials and methods
Organ doses were measured using thermoluminescent dosimeters (TLD-100) placed within a female Rando phantom for MVCT imaging. Kruskal–Wallis test was conducted with p<0·05 to evaluate the significant difference between the three MVCT scanning modes.
Results
Statistically significant difference existed in organ absorbed dose between different scan mode selections (p<0·001). Relative to the normal scan selection (4 mm), the absorbed dose to the organs of interests can be scaled down by 0·7 and scaled up by 2·1 for coarse (6 mm) and fine scans (2 mm) respectively.
Conclusions
Optimisation of imaging protocols is of paramount importance to keep the radiation exposure ‘as low as reasonably achievable’. The recommendation of undergoing daily coarse mode for MVCT verification in breast tomotherapy not only mitigates the radiation exposure to normal tissues, but also trims the scan-acquisition time.
Breast cancer is the most commonly diagnosed malignancy among women and accounts for about 25% of all new cancer cases and 13% of all cancer deaths in Canadian women. It is a highly heterogeneous disease, encompassing multiple tumour entities, each characterised by distinct morphology, behaviour and clinical implications. Moreover, different breast tumour subtypes have different risk factors, clinical presentation, histopathological features, outcome and response to systemic therapies. Therefore, any strategies capable of the stratification of breast cancer by clinically relevant subtypes are an important requirement for personalised and targeted treatment. Therefore, in the advancement towards the concept of precision medicine that takes individual patient variability into account, several investigators have focused on the identification of effective clinical breast cancer biomarkers that interrogate key aberrant pathways potentially targetable with molecular targeted or immunological therapies.
Methods and materials:
This paper reports on a review of 11 current clinical and emerging biomarkers used in screening for early detection and diagnosis, to stratify patients by disease subtype, to identify patients’ risk for metastatic disease and subsequent relapse, to monitor patient response to specific treatment and to provide clinicians the possibility of prospectively identifying groups of patients who will benefit from a particular treatment.
Conclusion:
The future holds promising for the use of effective clinical breast cancer biomarkers for early detection and personalised patient-specific targeted treatment and increased patient survival. Breast cancer biomarkers can potentially assist in early-staged, non-invasive, sensitive and specific breast cancer detection and screening, provide clinically useful information for identification of patients with a greater likelihood of benefiting from the specific treatment, offer a better understanding of the metastatic process in cancer patients, predict disease and for patients with the established disease can assist define the nature of the disease, monitor the success of treatment and guide the clinical management of the disease.
During left-sided breast radiotherapy, the heart is often exposed to radiation dose. Shielding can be utilised to reduce heart exposure, but compromises the dose delivered to the breast tissue and, in a proportion of patients, to the tumour bed. Deep inspiration breath hold (DIBH) can be used as a technique to move the heart away from the treatment area and thus reduce heart dose. This study examines the efficacy of the Elekta Active Breathing Coordinator (ABC), a DIBH method, in reducing heart dose.
Materials and methods
In total, 12 patients receiving radiotherapy to the left breast were planned for treatment with both a free-breathing (FB) and an ABC scan. The dose volume histogram data for the plans was analysed with respect to heart V13, V5 Gy, mean heart dose and ipsilateral lung V18 Gy. Tumour bed D98%, threshold lung volume in breath hold (BH) and the maximum BH time for each patient was also measured. Patients then received their radiotherapy treatment using the ABC plan and the systematic error in the craniocaudal, lateral and vertical axes was assessed using orthogonal imaging.
Results
The median heart V13 Gy for FB and DIBH patients was 3% (range, 0·85–11·28) and 0% (range, 0–1·56), respectively, with a mean heart dose of 2·62 Gy (range, 1·21–4·93) in FB and 1·51 Gy (range, 1·17–2·22) in ABC. The median lung V18 Gy was 8·7% (3·08–14·87) in FB plans and 9% (4·88–12·82) in ABC plans. The mean systematic set-up errors in all three planes were within the departmental set-up tolerance of 5 mm for both techniques. Median FB tumour bed D98% was 97·4% (92·8–99·5) and 97·5% (97·3–98·5) for ABC.
Conclusion
ABC represents a good method of reducing radiation dose to the heart while not compromising on dose to the tumour bed, and it has a clear advantage over FB radiotherapy in reducing the risk of cardiac toxicity. It is tolerated well by patients and does not produce any difficulties in patient positioning.
To evaluate the dosimetric parameters of level II lymph nodes in chest wall three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT) of mastectomy patients using dual-isocentric (DIT) and mono-isocentric techniques (MIT).
Materials and methods:
Computed tomography (CT) images of 20 mastectomy patients undergoing chest wall external radiotherapy were used as the input data for the abovementioned techniques. Selected dosimetric parameters were calculated for the axillary level I–III lymph nodes, chest wall, heart and lung. Paired t-test statistical analysis was used for comparing the results of MIT and DIT in both 3D-CRT and IMRT methods.
Results:
There were significant differences in Dmin (minimum dose), Dmax (maximum dose) and maximum–minimum dose between MIT and DIT techniques (13, −8·6, −52·2% differences for Dmin, Dmax and maximum–minimum, respectively) in IMRT. There were also significant differences for Dmean (mean dose), Dmax and maximum–minimum dose (7·8, −11·4, −44·6% differences in Dmean, Dmax and maximum–minimum, respectively) in 3D-CRT (p < 0·05). In addition, there were not any differences in the dosimetric parameters for heart, lung and level I and III lymph nodes.
Conclusion:
In both 3D-CRT and IMRT methods, level II lymph node dose distribution in MIT was closer to the prescribed dose compared with DIT due to the position of these nodes in the field junction area. To achieve a better dose homogeneity, it could be recommended to use MIT instead of DIT in 3D-CRT and IMRT for mastectomy patients.
The Early Breast Cancer Trialists’ Collaborative Group (EBCTCG) reported that the risks of breast cancer treatment in woman smokers may outweigh the benefits. The data used doses from published reports using a variety of treatment techniques. In our study, the risks of lung cancer and heart disease were determined from a modern era tangential-only technique.
Methods and materials
Doses to the lung and heart were obtained for tangential radiotherapy to the breast or chest wall. The risk of lung cancer incidence and cardiac mortality were calculated by taking the ratio of our doses to those published by the EBCTG.
Results
A total of 77 women were identified meeting our inclusion criteria. The mean combined whole lung dose was 2·0 Gy. The mean whole heart dose was 0·9 Gy. The estimated risk of lung cancer and cardiac mortality in a 50-year-old life-long smoker was estimated to be 1·5 and <1%, respectively.
Conclusions
Tangential only radiotherapy delivered substantially lower doses to the combined whole lung and whole heart than those reported by the EBCTCG. In this cohort, the risks of radiation induced lung cancer and heart disease are outweighed by the benefits of radiotherapy even in those that are smokers.
To determine which concomitant boost technique is dosimetrically superior in the treatment of breast cancer; volumetric-modulated arc therapy (VMAT) or fixed field intensity-modulated radiotherapy (ff-IMRT).
Materials and methods
In total, 30 breast patients were re-planned with both VMAT and fixed field concomitant boost intensity-modulated radiotherapy techniques. A hybrid technique was used delivering 80% of the dose through tangential beams and 20% through an integrated boost. A two-tailed t-test sample for means was used to compare the dosimetric differences between the techniques.
Results
Maximum dose was statistically lower for VMAT; 103·2 versus 103·7% for ff-IMRT along with statistically lower V2 Gy doses to the contralateral lung (0·7 versus 1·6%) and heart for both left- (19·0%/22·6%), and right- (5·5%/8·8%) sided patients, respectively. ff-IMRT boasted significantly lower ipsilateral lung V20, V18 and V10 Gy (7·9/8·6/13·1 versus 8·1/8·8/13·4%) than VMAT, respectively. No differences were found with minimum coverage, mean dose and V5 Gy to all organs at risk (OARs).
Conclusion
VMAT and ff-IMRT techniques demonstrate excellent target coverage and OAR sparing facilitated by the hybrid planning technique and deep inspiration breath hold. There is no obvious dosimetrically superior option between the two techniques. Reduced treatment times with VMAT make it more desirable to implement clinically.