We partner with a secure submission system to handle manuscript submissions.
Please note:
You will need an account for the submission system, which is separate to your Cambridge Core account. For login and submission support, please visit the
submission and support pages.
Please review this journal's author instructions, particularly the
preparing your materials
page, before submitting your manuscript.
Click Proceed to submission system to continue to our partner's website.
To save this undefined to your undefined account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you used this feature, you will be asked to authorise Cambridge Core to connect with your undefined account.
Find out more about saving content to .
To send this article to your Kindle, first ensure no-reply@cambridge.org is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about sending to your Kindle.
Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
Patients with CHD exhibit reduced isometric muscle strength and muscle mass; however, little is known how these parameters relate. Therefore, the aim was to investigate the relation between isometric limb muscle strength and muscle mass for patients in comparison to age- and sex-matched control subjects.
Methods:
Seventy-four patients (35.6 ± 14.3 years, women n = 22) and 74 matched controls were included. Isometric muscle strength in elbow flexion, knee extension, and hand grip was assessed using dynamometers. Lean mass, reflecting skeletal muscle mass, in the arms and legs was assessed with dual-energy x-ray absorptiometry.
Results:
Compared to controls, patients had lower muscle strength in elbow flexion, knee extension, and hand grip, and lower muscle mass in the arms (6.6 ± 1.8 kg versus 5.8 ± 1.7 kg, p < 0.001) and legs (18.4 ± 3.5 kg versus 15.9 ± 3.2 kg, p < 0.001). There was no difference in achieved muscle force per unit muscle mass in patients compared to controls (elbow flexion 0.03 ± 0.004 versus 0.03 ± 0.005 N/g, p = 0.5; grip strength 0.008 ± 0.001 versus 0.008 ± 0.001 N/g, p = 0.7; knee extension 0.027 ± 0.06 versus 0.028 ± 0.06 N/g, p = 0.5). For both groups, muscle mass in the arms correlated strongly with muscle strength in elbow flexion (patients r = 0.86, controls, r = 0.89), hand grip (patients, r = 0.84, controls, r = 0.81), and muscle mass in the leg to knee extension (patients r = 0.64, controls r = 0.68).
Conclusion:
The relationship between isometric muscle strength and limb muscle mass in adults with CHD indicates that the skeletal muscles have the same efficiency as in healthy controls.
Interestingly, our case presenting with coronary AV fistula firstly reported in the literature with fetal valproate syndrome. Although differential diagnosis is sometimes difficult, it can be diagnosed with detailed history, physical examination and appropriate laboratory tests. Fetal valproate syndrome can be prevented by discontinue of the valproic acid especially during first trimester of pregnancy.
Shape-memory abnormalities are seen in some nitinol atrial septal occluders. Variably described as cobra-head, tulip, and others, their incidence, mechanisms, clinical impact, and outcome have not been systematically analysed.
Methods:
We retrospectively reviewed all consecutive device closures in the last 6 years for deformations. Type and size of the occluder, deployment technique, size, and angulation/kinking of the delivery sheath were analysed. Procedural success, duration, and other complications were studied.
Results:
A total of 112 devices (11.8%) among 950 occluders used in 936 patients showed deformities. Fourteen of 936 received 2 devices. Deformities were transient and self-correcting in 40%. Multivariate analysis showed significant associations with oversized sheaths (p = 0.004), kinked/angulated sheaths (p < 0.001), special deployment techniques (p < 0.001), and twist in the device waist (p = 0.011). Despite more frequent deformities with Figulla (15.6%) and Amplatzer (13.9%) occluders than Cera occluders (6.6%) and larger devices (>24 mm – 14.6%) than smaller devices (less than or equal to 24 mm – 9.7%), they were not significant on multivariate analysis. In vivo manipulations corrected most deformities; nineteen needed in vitro reformations and four needed a change of device. Despite prolongation of the procedure, repeated attempts (mean 2.76 ± 1.7 attempts, with a range from 1 to 9 attempts), and supraventricular tachycardia in two patients, there were no serious adverse effects.
Conclusions:
Deformations were frequent in 11.8% of atrial septal occluders on a targeted search. Oversized and angulated/kinked sheaths, special techniques like pulmonary vein deployment and twist in device waist during procedure predisposed to deformities. While most deformities were corrected with manipulations, removal of the device was infrequently needed and change of device was rarely required. Long procedural time and multiple attempts for deployment did not affect procedural success.
A 14-year-old girl admitted for corrective surgery for tetralogy of Fallot was found to have pulmonary arteriovenous malformations on pre-operative evaluation. In anticipation of a complicated postoperative course, percutaneous closure of the pulmonary arteriovenous malformations was undertaken first followed by a successful surgical outcome. Importance of this rare association and its clinical implication is hereby highlighted.
Although surgery is the standard treatment for native coarctation in neonates, it carries a high risk of complications. Percutaneous balloon angioplasty may be considered as an alternative treatment. The materials used in the intervention should be selected carefully to reduce complications. We recommended the use of non-compliant balloons in risky babies. They are more effective in the treatment of strick stenosis than compliant balloons.
Tricuspid valve atresia with severe pulmonary stenosis is one of the common cyanotic diseases in neonate. Child can succumb due to profound cyanosis and arterial hypoxaemia after closure of patent ductus arteriosus. Evolving procedure of right ventricular outflow tract stenting may be considered as a palliative procedure in such vulnerable group, destined for a later definitive management. The right ventricular outflow tract stenting is described essentially for tetralogy of Fallot physiology with a catheter course across tricuspid valve. We describe a case of successful right ventricular outflow tract stenting in a 5-day-old symptomatic neonate. We discuss the possible routes and the tips to facilitate right ventricular outflow tract stenting in such a case. This happens to be the first reported case description with successful stenting of neonate with tricuspid atresia with critical pulmonic stenosis.
Ventricular septal defect is the most common type of CHD, and transcatheter ventricular septal defect closure has been shown to be an alternative to surgical closure with acceptable mortality and morbidity as well as encouraging results. Short-term and mid-term follow-ups have indicated the safety and efficacy of transcatheter closure, but long-term follow-up results were rare. In this report, we first found that aortic regurgitation occurred in patients 9–12 years following transcatheter closure and regurgitation were gradually increased. The findings indicate that the long-term outcome of transcatheter closure of ventricular septal defect may not be as satisfied as expected.
A 29-month-old girl had idiopathic massive pericardial effusion for over 6 months. Lymphangiography was performed for chronic and recurrent pericardial effusion and pulmonary lymphangiectasia, suspected based on CT findings. Magnetic resonance lymphangiography revealed chylolymphatic reflux from a tortuously dilated thoracic duct in the mediastinum to the pericardial space, suggesting primary chylopericardium with lymphangiectasia. Pericardial effusion resolved immediately after thoracic duct embolisation at the lower thoracic level. However, pericardial effusion recurred after 5 months, which resolved after additional embolisation of the abnormal lymphatic collateral vessels from the remnant upper thoracic duct. Here, we report an unusual case with chylous massive pericardial effusion diagnosed by magnetic resonance lymphangiography and treated with percutaneous embolisation.
We report a case of Figulla-II Occlutech septal occluder malposition with residual shunt at posteriosuperior margin of an atrial septal defect. Improvising its bioptome type delivery cable, same system was used to recapture the device and redeploy it successfully. This report highlights a potential malfunction of Figulla-II Occlutech disc and the advantage of its delivery system for retrieval of the device.
Patients with Williams syndrome often present with abnormalities of the vascular wall of the aorta and/or the pulmonary artery. Surgery may result in restenosis of the affected vessel. Herein, we report a case of an infant with multiple recurrences of aortic coarctation successfully treated with Zotarolimus drug-eluting stent.
Aortopulmonary window is a rare cardiac defect, and early management with surgery or transcatheter closure is lifesaving. Here, a 9-month-old patient, who underwent a successful device closure with additional size-Amplatzer duct occlude, is presented to make emphasis that it may be considered as the device of choice for defects in close proximity to aortic valve and/or coronary ostium.
Patent ductus arteriosus is the most common cardiovascular abnormality in premature infants. With newly available percutaneous devices, centres are reporting high rates of success and favourable safety profiles with percutaneous closure of haemodynamically significant ductus arteriosi in infants under 1000 g. We report the case of a 5-week-old, previous 25-week gestation, 1200-g infant who underwent successful percutaneous closure of a ductus arteriosus with a Medtronic Microvascular Plug but who developed late-term coarctation from the device. This case should prompt practitioners to consider the need and timing of follow-up echocardiograms in this population and sheds light on a newly reported long-term complication of device closure in premature infants.
A 7-month-old infant presented with bilateral blocked cavo-pulmonary anastomosis within 2 months of surgery. Due to extreme haemodynamic instability, surgical options were abandoned and rescue intervention from left jugular line was planned. Acute thrombosis of the left-sided Glenn was noted with significant anastomotic narrowing. Successful rescue thrombolysis was done using recombinant tissue plasminogen activator (Alteplase) along with balloon dilatation of the attenuated segments.
Congenital right pulmonary artery to left atrium fistula is rare cause of cyanosis. It is an abnormal fistulous connection between right pulmonary artery and left atrium representing a direct communication between a pulmonary artery and vein with absence of capillary network connecting between these two. Cardiovascular examination usually remains normal. High index of suspicion on clinical examination and subsequent transthoracic echocardiography is needed to suspect this entity. Bubble contrast echocardiography usually confirms the diagnosis. Cardiac catheterization is used as diagnostic as well as therapeutic modality. Cardiac catheterization is useful in classifying the fistula and helps in transcatheter closure by embolization devices. Choice of devices depends on type of fistula, vascular access, and presence of atrial communication. Here, we are reporting 8-month-old girl presenting with type 2 right pulmonary artery to left atrium fistula, which underwent successful transcatheter closure by 6 mm/4 mm duct occluder (Heart R, Lifetech Scientific, Shenzhen, China). Early closure in this young age will prevent complications of cyanosis. The technical consideration, possible access, and closure techniques are discussed in this young infant.
A child undergoing routine transcatheter patent arterial duct closure developed severe transient ischemic changes in the electrocardiogram (Pardee waves) while the aortic retention skirt of the Amplatzer™ Duct Occluder was pulled against the duct orifice. The occluder was then released, and the delivery system was pulled back to inferior caval vein which led to electrocardiogram normalisation. Aortic root angiography showed a single coronary artery originating from the right sinus of Valsalva with the left coronary stem wedged behind the posterior aspect of the right ventricular outflow tract. We believe that the left coronary artery was compressed while applying tension on the occluder delivery system.
A 10-year-old female with heterotaxy-asplenia and complex CHD developed pulmonary arteriovenous malformations with associated cyanosis after Fontan completion. She underwent orthotopic heart transplantation, but her pulmonary arteriovenous malformations persisted with progressive worsening cyanosis. Elective transcatheter left pulmonary artery embolisation was performed 2 years post-transplant, which successfully normalised her oxygen saturation without a significant increase in pulmonary artery pressure.
Cardiac catheterisation in patients on extracorporeal membrane oxygenation (ECMO) may reveal new information leading to modification of a therapeutic plan and correction of newly recognised or residual lesions. Complications associated with cardiac catheterisation during ECMO are not uncommon and often related to the access site. We report a straightforward technique for accessing the ECMO circuit to perform an emergent cardiac catheterisation in two patients with hypoplastic left heart syndrome decompensated after Norwood I, due to presumed systemic-to-pulmonary artery shunt obstruction.
We report on a 12-year-old girl with Ebstein’s anomaly after a unidirectional Glenn procedure with surgical ligation of the proximal right pulmonary artery, who suffered from significant central cyanosis caused by multiple arterio-venous fistulas in the right lung. The continuity between the right pulmonary artery and the pulmonary trunk was restored with the use of radiofrequency perforation and consecutive covered stent implantation.
A new approach was used in the percutaneous treatment of two patients with severe recoarctation involving the origin of the left subclavian artery. A tiny handmade fenestration was created in a NuMED-covered Cheatham-platinum stent before its implantation to avoid left subclavian artery occlusion. The stent placement was performed using a two-guidewire technique in which the different stiffness helped a proper positioning of the stent. After the stent deployment, the fenestration was enlarged performing a balloon angioplasty to improve flow in left subclavian artery.