We partner with a secure submission system to handle manuscript submissions.
Please note:
You will need an account for the submission system, which is separate to your Cambridge Core account. For login and submission support, please visit the
submission and support pages.
Please review this journal's author instructions, particularly the
preparing your materials
page, before submitting your manuscript.
Click Proceed to submission system to continue to our partner's website.
To save this undefined to your undefined account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you used this feature, you will be asked to authorise Cambridge Core to connect with your undefined account.
Find out more about saving content to .
To send this article to your Kindle, first ensure no-reply@cambridge.org is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about sending to your Kindle.
Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
To compare the acute radiation-induced bowel and bladder toxicities of two hypofractionated radiotherapy (HFRT) regimens in localised prostate cancer (PCa).
Materials and methods:
This trial consists of patients with histologically confirmed stage T1-T3aN0M0 PCa, a prostate-specific antigen concentration of 40 ng/mL or lower, and Eastern Cooperative Oncology Group performance status of 0–2. Participants were randomly assigned (1:1) to 56 Gy in 16 fractions over 4 weeks (arm A) or 70·2 Gy in 26 fractions over 5 weeks (arm B). Acute bowel and bladder toxicities were assessed using Radiation Therapy Oncology Group criteria.
Results:
Between June 2018 and December 2019, 40 patients were randomly assigned to treatment with 4-week (n = 20) and 5-week HFRT (n = 20). In the third month after completion of radiotherapy, the cumulative incidence of acute bowel and bladder toxicities of arms A and B was 20 versus 5% and 70 versus 85%, respectively. The cumulative incidence of grade 2 or worse bowel and bladder toxicities of the 5-week regimen was non-inferior to 4-week HFRT [bowel toxicity: 5% (arm A) versus 5% (arm B), bladder toxicity: 50% (arm A) versus 60% (arm B), p = 0·52).
Findings:
The 5-week regimen of HFRT is non-inferior to 4-week HFRT in terms of acute bowel and bladder toxicities.
The present study reports myeloablative total body irradiation (TBI) on an isocentrically mounted linac by laying the patient on the floor and management of abutting radiation fields and partial shielding of lungs. Dosimetrical efficacy of this novel technique was evaluated.
Materials and methods:
In this retrospective study, dosimetrical parameters from TBI plans on whole-body CT scans of 46 patients were analysed. The prescribed dose to TBI was 12 Gy in six fractions delivered over a period of 3 days for myeloablative conditioning. TrueBeam STx platform Linac (Varian Medical Systems Inc., Palo Alto, CA, USA) was used to deliver opposing fields. Radiation fields were abutted to form a single large field using an arithmetic formula at source-to-skin-distance of 210 cm.
Results:
Discrepancies in dose calculated by treatment planning system were within 1·6% accuracy, and dose profile at the junction of abutting radiation fields was reproduced within 3·0% accuracy. The real treatment time for each patient was ~30 minutes/fraction. Monitor unit was weighted for multiple sub-fields to achieve dose homogeneity within 5·0% throughout the whole body, and the mean dose to lung was ≤10 Gy.
Conclusion:
Our abutting radiation field technique for myeloablative TBI is feasible in any existing linac bunker. ‘Island-blocking’ is feasible in this technique using multi-leaf collimator. This technique is cost-effective as it does not require any costly equipment than the readily available equipment in any radiotherapy facility. In general, TBI requires laborious planning procedures and spacious linac bunkers; this novel technique has the potential to change previously held notions.
Salivary duct carcinoma (SDC) is an extremely rare and aggressive subtype of salivary gland cancer with high morbidity and mortality and poor response to treatment. The current options of treatment include radical surgery followed by radiotherapy (RT) with or without chemotherapy. The aim of this study was to analyse the patterns of recurrences, possible predictors of outcome and role of RT in a cohort of patients with non-metastatic SDC.
Methods:
A retrospective review of patients treated between 2010 and 2019 with histologically proven non-metastatic SDC was conducted.
Results:
Sixteen patients were included in the series. Median follow-up was 25 months. Progression-free survival (PFS) and overall survival (OS) at 12 months were 61% and 80%, respectively. Seven out of the 16 patients had disease progression, distant metastases being most frequent. Four patients died due to disease progression. PFS was significantly worse for patients with pathological neck node positivity (p = 0·036) and peri-parotid nodes (p = 0·007). Local control was significantly associated with RT (p = 0·011). Addition of any chemotherapy, regardless of either concurrent or adjuvant, had no impact on the PFS or OS. Pathological neck node positivity with nodal stage of N2 or higher correlated significantly with worse OS (p = 0·031).
Conclusion:
Salivary ductal carcinoma is an aggressive malignancy with high metastatic potential. Inferior prognosis was observed among patients who had metastatic deposits in either cervical nodes or peri-parotid nodes on histopathology. As systemic failures are more predominant among these patients, larger prospective trials are needed to formulate an optimum strategy for choice and sequencing of first-line systemic therapy.
The purpose of the present study was to assess the accuracy of radiotherapy (RT) structure volume generated by the Monaco treatment planning system (TPS) for three different computed tomography (CT) slice thicknesses. Further, this study addressed the important issue of ‘different volumes of the same RT structure shown at different places’ in the Monaco TPS. Also, the practical impact of this difference in structure volumes has been studied for brain or head and neck patients.
Materials and Methods:
Objects of known volumes were scanned with different CT slice thicknesses and contoured as an RT structure in Monaco TPS and two different volumes provided by the TPS for each RT structure were noted and compared with the real volumes of these objects. In addition, correlation was also assessed between TPS provided volumes and real volumes of these objects. The study was further extended to obtain correlation of volumes in cases of organs that exist in pairs (e.g., eye) in the human body.
Results:
Monaco TPS overestimates structure volumes except for objects with sharp corners. Although, volumes shown at different places of the same structure have nearly a linear correlation, volumes under structure table are more accurate than those shown under dose–volume histogram (DVH) statistics (total volume) table. Difference in magnitude between these two volumes has no correlation if this difference is analysed for paired organs.
Findings:
This study confirmed that Monaco TPS provides ‘different value at different places’ of the volume of a given contoured structure. It is recommended that this issue should be reviewed and resolved by the supplier.
Dosimetric comparison between volumetric-modulated arc therapy (VMAT) and helical tomotherapy (HT) in the treatment of bilateral breast cancer (BBC).
Materials and methods:
Ten patients treated on HT were selected retrospectively. Dose prescription was 50 Gy in 25 fractions to breast/chest wall and supraclavicular fossa (SCF) while tumour bed was simultaneously boosted to 61 Gy in 25 fractions. VMAT plans were made with four mono-isocentric partial arcs. The monitoring unit (MU) and treatment time were used to quantify the treatment efficiency. Target volumes were compared for homogeneity index (HI), conformity index (CI) while organs at risk (OARs) were compared for relevant dose volumes and integral doses (IDs).
Result:
For targets, no significant difference is observed between VMAT and HT in CI but VMAT could give better HI. The mean lung dose, V20 and V5 is 10·6 Gy versus 8·4 Gy (p-value 0·03), 12% versus 11·5% (p-value 0·5) and 78·1% versus 43·4% (p-value 0·005), respectively. The mean heart dose, V30 and V5 is 4·9 Gy versus 4·7 Gy (p-value 0·88), 0·5% versus 1·5% (p-value 0·18) and 26·2% versus 22·8% (p-value 0·4). Integral dose (ID) for the whole body and heart are comparable: 289 Gy kg versus 299 Gy kg (p-value 0·24) and 2·9 Gy kg versus 2·8 Gy kg (p-value 0·80). ID for lungs was significantly higher with VMAT: 7·9 Gy kg versus 6·3 Gy kg (p-value 0·03). There is a 53% reduction in treatment time and 78% in MU with VMAT against HT.
Conclusion:
VMAT can generate clinically acceptable plans comparable to HT for BBC. HT shows better control over low dose spillage in lungs compared to VMAT thereby increasing ID to lungs. VMAT shows better homogeneity and efficient treatment delivery than HT.
To explore student therapeutic radiographers’ understanding of obesity and cancer and to identify if student therapeutic radiographers believe that radiographers should have a role within weight management.
Materials and Methods:
This study used a self-completed online questionnaire (google forms) to collect data from Radiotherapy and Oncology students, studying at one Higher Education Institution, to gain an understanding of their current knowledge of weight management. A retrospective margin of error calculation was carried out, showing a 9% margin of error with a 90% confidence level.
Results:
In total 57 responses were received, n = 50 BSc students and n = 7 pre-registration MSc students. Three key barriers to openly discussing weight loss management with service users emerged from the questionnaire data; these were a lack of time, lack of clear guidelines and lack of confidence. These barriers could potentially be addressed by improving education and training, making it easier for therapeutic radiographers to openly discuss weight management with service users.
Findings:
Awareness of guidelines was suboptimal, with 82% (n = 47) of respondents unaware of any guidelines. In addition to this, the majority of students identified a lack of confidence as a barrier to them providing weight management advice. Despite this, 54·4% of respondents agreed that radiographers should have a role in providing weight management advice, with 22·2% of respondents being unsure. Findings suggest that behaviour change is required amounts both students and staff members, so that healthcare professionals are more inclined to have healthy weight management discussions. Perhaps more specialist roles need to be developed, so that healthy weight management discussions can become a norm.
The patient experience of radiotherapy magnetic resonance (MR) simulation is unknown. This study aims to evaluate the patient experience of MR simulation in comparison to computed tomography (CT) simulation, identifying the quality of patient experience and pathway changes which could improve patient experience outcomes.
Materials and Methods:
MR simulation was acquired for 46 anal and rectal cancer patients. Patient experience questionnaires were provided directly after MR simulation. Questionnaire responses were assessed after 33 patients (cohort one). Changes to the scanning pathway were identified and implemented. The impact of changes was assessed by cohort two (13 patients).
Results:
Response rates were 85% (cohort one) and 54% (cohort two). 75% of cohort one respondents found the magnetic resonance imaging (MRI) experience to be better or similar to their CT experience. Implemented changes included routine use of blankets, earplugs and headphones, music and feet-first positioning and further MRI protocol optimisation. All cohort two respondents found the MRI experience to be better or similar to the CT experience.
Findings:
MR simulation can be a comfortable and positive experience that is comparable to that of standard radiotherapy CT simulation. Special attention is required due to the fundamental differences between CT and MRI scanning.
The control points (CP) play a significant role in the delivery of segmented based Intensity-Modulated Radiation Therapy (IMRT) delivery, particularly in dynamic mode. The number of segments is determined by control points and these segments will transfer from one to the other either during beam ON called dynamic delivery or during beam OFF called static delivery or step and shoot. This study was aimed at indirect estimation of the total monitor units (MU) to be delivered per field by exploiting the control points and also to find the MUs at any nth segment.
Materials and methods:
This study was performed in the Eclipse treatment planning software version 13.8.0. The details of control points, metre set weight per segment, leaf positions for each segment, field size, etc. were taken into consideration.
Results:
TPS calculated MU value and analytically estimated MU value were compared and the percentage of difference was estimated. The overall mean percentage of deviation was 1·03% between the TPS calculated method and the analytical method. The paired sample t-test was performed and, p-value <0·05, no significant difference was found. The analytical relationship determined to estimate the total number of MU delivered for any nth control point was also evaluated.
Conclusion:
The control points are a potential parameter in the conventional IMRT delivery. Through this study, we have addressed the indirect method to estimate the monitor units delivered per segment.
In radiation therapy, accurate dose distribution in target volume requires accurate treatment setup. The set-up errors are unwanted and inherent in the treatment process. By achieving these errors, a set-up margin (SM) of clinical target volume (CTV) to planning target volume (PTV) can be determined. In the current study, systematic and random set-up errors that occurred during prostate cancer radiotherapy were measured by an electronic portal imaging device (EPID). The obtained values were used to propose the optimum CTV-to-PTV margin in prostate cancer radiotherapy.
Materials and methods:
A total of 21 patients with prostate cancer treated with external beam radiation therapy (EBRT) participated in this study. A total of 280 portal images were acquired during 12 months. Gross, population systematic (Σ) and random (σ) errors were obtained based on the portal images in Anterior–Posterior (AP), Medio-Lateral (ML) and Superior–Inferior (SI) directions. The SM of CTV to PTV were then calculated and compared by using the formulas presented by the International Commission on Radiation Units and Measurements (ICRU) 62, Stroom and Heijmen and Van Herk et al.
Results:
The findings showed that the population systematic errors during prostate cancer radiotherapy in AP, ML and SI directions were 1·40, 1·95 and 1·94 mm, respectively. The population random errors in AP, ML and SI directions were 2·09, 1·85 and 2·29 mm, respectively. The SM of CTV to PTV calculated in accordance with the formula of ICRU 62 in AP, ML and SI directions were 2·51, 2·68 and 3·00 mm, respectively. And according to Stroom and Heijmen, formula were 4·23, 5·19 and 5·48 mm, respectively. And Van Herk et al. formula were 4·96, 6·17 and 6·45 mm, respectively.
Findings:
The SM of CTV to PTV in all directions, based on the formulas of ICRU 62, Stroom and Heijmen and van Herk et al., were equal to 2·73, 4·98 and 5·86 mm, respectively; these values were obtained by averaging the margins in all directions.
Teamwork is a central framework in healthcare delivery. Team dynamics can impact the team as a whole and has been identified within the literature as a contributory factor to quality and safety, patient satisfaction, staff satisfaction and overall performance. Within radiation therapy (RT), teamwork is essential in the delivery of high-quality care, yet team building and team development is under-reported.
Aim:
The focus of this research is to form a better understanding of what plays an impact on teams in a large urban RT cancer centre and how to better engage staff to work together, improve team dynamics and promote team building.
Materials and Methods:
An electronic search of the literature was conducted to better inform debate and aid in the development of team-building sessions in a busy radiotherapy department. Abstracts were screened and relevant articles selected if they met the search criteria that included relevancy related to team building, contributory factors on team dynamics, team-based learning, team performance and implication of civility.
Results:
A total of 45 articles were included in the final analysis. The majority were from the disciplines of medicine (45%), business (22%) and nursing (18%). Only 3 of the 45 articles (7%) focused on the profession of RT. Most articles discussed more than 1 theme with team dynamics and team building being the most common themes discussed in 16 articles each (36%). Other common themes included teamwork (31%), respect and civility (20%), leadership and hierarchy (11%), medical errors (11%) and team training (11%). Only 3 of the 45 articles (7%) focused on RT.
Conclusion:
There is a lack of longitudinal evidence to support the impact of team building sessions to improve team dynamics and promote a positive, cohesive team environment. Specifically within RT, the impact team building has on team dynamics has been under investigation.
Highlights:
High-quality patient care can be linked to team collaboration and cohesiveness. Changing the culture within a team and engaging in civility and respect in everyday practice has the potential to improve team dynamics, patient safety, staff and patient satisfaction.
Choroidal metastases are the most frequent intraocular secondary tumours, with a prevalence of 2–7% according to the literature. Our aim was to review a clinical case of choroidal metastasis.
We present a case of a 63-year-old male patient diagnosed in 2018 with lung adenocarcinoma cT4N0M1. The patient had three metastases in the brain, which were successfully treated with radiosurgery (RS). The patient was treated with chemotherapy with pemetrexed–cisplatin schedule. Five months after diagnosis, the patient presented with decreased vision in the right eye. After ophthalmologic evaluation, he was diagnosed with a right choroidal metastasis, which was treated with external beam radiotherapy with 20 Gy in five fractions, resulting in improved visual acuity and a complete clinical and radiological response.
The patient took part in a clinical trial that continued with systemic chemotherapy. Twenty-two months after radiotherapy to the eye, the patient has good visual acuity without any side effects.
Conclusions:
Choroidal metastasis treated with radiotherapy achieves good local control, with limited side effects, allowing an improvement in visual acuity and consequently, an improvement in the patient´s quality of life.
Brain metastases (BM) are common in patients with HER2-positive and triple-negative breast cancer. In this study we aim to report clinical outcomes with LINAC-based stereotactic radiosurgery/radiotherapy (SRS/SRT) for BM in patients of breast cancer.
Methods:
Clinical and dosimetric records of breast cancer patients treated for BM at our institute between May, 2015 and December, 2019 were retrospectively reviewed. Patients of previously treated or newly diagnosed breast cancer with at least a radiological diagnosis of BM; 1–4 in number, ≤3·5 cm in maximum dimension, with a Karnofsky Performance Score of ≥60 were taken up for treatment with SRS. SRT was generally considered if a tumour was >3·5 cm in diameter, near a critical or eloquent structure, or if the proximity of moderately sized tumours would lead to dose bridging in a single-fraction SRS plan. The median prescribed SRS dose was 15 Gy (range 7–24 Gy) and SRT dose was 27 Gy in 3 fractions.
Clinical assessment and MR imaging was done at 6 weeks post-SRS and then every 3 months thereafter. Intracranial progression-free survival (PFS) and overall survival (OS) were calculated using Kaplan–Meier method and subgroups were compared using log rank test.
Results:
Total, 40 tumours were treated in 31 patients. The median tumour diameter was 2·3 cm (range 1·0–4·6 cm). SRS and SRT were delivered in 27 and 4 patients, respectively. SRS/SRT was given as a boost to whole brain radiotherapy (WBRT) in four patients and as salvage for progression after WBRT in six patients. In general, nine patients underwent prior surgery. The median follow-up was 7·9 months (0·2–34 months). Twenty (64·5%) patients developed local recurrence, 10 (32·3%) patients developed distant intracranial relapse and 7 patients had both local and distant intracranial relapse. The estimated local control at 6 months and 1 year was 48 and 35%, respectively. Median intracranial progression free survival (PFS) was 3·73 months (range 0·2–25 months). Median intracranial PFS was 3·02 months in patients who received SRS alone or as boost after WBRT, while it was 4·27 months in those who received SRS as salvage after WBRT (p = 0·793). No difference in intracranial PFS was observed with or without prior surgery (p = 0·410). Median overall survival (OS) was 21·7 months (range 0·2–34 months) for the entire cohort. Patients who received prior WBRT had a poor OS (13·31 months) as compared to SRS alone (21·4 months; p = 0·699).
Conclusion:
In patients with BM after breast cancer SRS alone, WBRT + SRS and surgery + SRS had comparable PFS and OS.
To identify prognostic factors and investigate patient survival after whole-brain radiotherapy (WBRT) for initial brain metastases arising from non-small cell lung cancer (NSCLC).
Methods:
Patients diagnosed with NSCLC between 1 January 2010 and 30 September 2019, and who received WBRT upon first developing a brain metastasis, were investigated. Overall survival was determined as related to age, sex, duration between initial examination and brain metastasis detection, stage at the first examination, presence of metastases outside the brain, blood analysis findings, brain metastasis symptoms, radiotherapy dose and completion, imaging findings, therapeutic course of chemotherapy and/or radiation therapy, histological type, and gene mutation status.
Results:
Thirty-one consecutive patients (20 men and 11 women) with a mean age of 63·8 years and median survival of 129 days were included. Multivariate analysis with stepwise testing was performed to investigate differences in survival according to gene mutation status, lactate dehydrogenase (LDH) level, irradiation dose, WBRT completion and Stage status. Of these, a statistically significant difference in survival was observed in patients with gene mutation status (hazard ratio: 0·31, 95% CI: 0·11–0·86, p = 0·025), LDH levels <230 vs. ≥230 IU/L (hazard ratio: 4·08, 95% CI: 1·45–11·5, p < 0·01) received 30 Gy, 30 Gy/10 fractions to 35 Gy/14 fractions, and 37·5 Gy/15 fractions (hazard ratio: 0·26, 95% CI: 0·09–0·71, p < 0·01), and stage IV versus non-stage IV (hazard ratio: 0·13, 95 CI:0·02–0·64, p < 0·01)
Findings:
Gene mutation, LDH, radiation dose and Stage are prognostic factors for patients with initial brain metastases who are treated with WBRT.
The objective of radiotherapy immobilisation devices is to improve the reproducibility of patient positioning during treatment sessions. The inclusion of these devices in the treatment protocol may increase the skin dose. In practice, these devices are not systematically taken into account in the dose calculation.
Material and methods:
In this study, the dosimetric effects of the carbon fibre couch iBEAM Evo Extension 415, with and without three different immobilisation devices (a Klarity Breastboard R610-2ECF, a Bionix Butterfly Board and CIVCO Vac-Lok vacuum bag), were calculated and evaluated on the dose calculation for conformal three-dimensional radiation therapy. The measurements were carried out by comparing the measured dose with the one calculated for three different algorithms, FFT convolution, fast superposition and superposition algorithms, which are implemented in Xio treatment planning system (TPS).
Results:
Dosimetric tolerance levels have been respected for specific dose calculations, which do not include the fibre couch with or without immobilisation devices. Errors of up to 8% in the dose calculation were obtained for the beams passing through the fibre couch and the breast board base support region.
Conclusion:
According to the significant attenuation differences of the beam by the fibre couch and immobilisation devices, it was concluded that ignoring the device in the dose calculation can change patient’s skin and target doses. The fibre couch and immobilisation device should be included within external body contour to account for the TPS calculation algorithms dose attenuation.
Electron blocks are typically composed of a low melting point alloy (LMPA), which is poured into an insert frame containing a manually placed Styrofoam aperture negative used to define the desired field shape. Current implementations of the block fabrication process involve numerous steps which are subjective and prone to user error. Occasionally, bowing of the sides of the insert frame is observed, resulting in premature frame decommissioning. Recent works have investigated the feasibility of utilising 3D printing technology to replace the conventional electron block fabrication workflow; however, these approaches involved long print times, were not compatible with commonly used cadmium-free LMPAs, and did not address the problem of insert frame bowing. In this work, we sought to develop a new 3D printing technique that would remedy these issues.
Materials and Methods:
Electron cutout negatives and alignment jigs were printed using Acrylonitrile Butadiene Styrene, which does not warp at the high temperatures associated with molten cadmium-free alloys. The accuracy of the field shape produced by electron blocks fabricated using the 3D printed negatives was assessed using Gafchromic film and beam profiler measurements. As a proof-of-concept, electron blocks with off-axis apertures, as well as complex multi-aperture blocks to be used for passive electron beam intensity modulation, were also created.
Results:
Film and profiler measurements of field size were in excellent agreement with the values calculated using the Eclipse treatment planning system, showing less than a 1% difference in line profile full-width at half-maximum. The multi-aperture electron blocks produced fields with intensity modulation ≤3.2% of the theoretically predicted value. Use of the 3D printed alignment jig – which has contours designed to match those of the insert frame – was found to reduce the amount of frame bowing by factors of 1.8 and 2.1 in the lateral and superior–inferior directions, respectively.
Conclusions:
The 3D printed ABS negatives generated with our technique maintain their spatial accuracy even at the higher temperatures associated with cadmium-free LMPA. The negatives typically take between 1 and 2 hours to print and have a material cost of approximately $2 per patient.
The purpose of the study was to evaluate the impact of changes in breathing pattern inside the breath-hold window (BHW) during deep inspiration breath hold treatment for carcinoma left breast patients post-conservative surgery.
Methods:
Ten patients of carcinoma left breast post-conservative surgery were prospectively selected. Three sets of CT plain images were acquired, one with 5 mm deep inspiration BHW (DIBHR) and the other one with 1 mm BHW matching the lower threshold (DIBHL) and the third one with 1 mm BHW matching the upper threshold (DIBHH) as DIBHR. For all patients, forward intensity-modulated radiotherapy (FIMRT) and volumetric modulated arc therapy (VMAT) plans were generated in the 5 mm BHW CT series and the same plan being copy and pasted in other series. Target volume doses and critical structure doses were tabulated.
Results:
Planning target volume coverage was adequate and no significant differences were found in any CT series. Significant differences noted in average left lung V5%, V10% and V18% doses between DIBHR versus DIBHH (p values = 0·0461, 0·0283 and 0·0213, respectively) and DIBHL versus DIBHH (p values = 0·0434, 0·0484 and 0·0334, respectively) for FIMRT plans and V18% doses in DIBHR versus DIBHH (p = 0·0067) in VMAT. No differences in heart and apex of heart doses were found. Left anterior descending artery (LAD) mean doses were significant in DIBHL versus DIBHR, DIBHR versus DIBHH and DIBHL versus DIBHH (p = 0·0012, 0·0444 and 0·0048, respectively) series for FIMRT plans and DIBHR versus DIBHH and DIBHL versus DIBHH (p = 0·0341, 0·0001) for VMAT plans.
Finding:
The changes in the breathing pattern inside DIBH window level cause some variation in LAD doses and no other significant differences in any parameters noted, so care should be taken while treating patients with preexisting cardiac conditions.
The Pinnacle3 Auto-Planning (AP) package is an automated inverse planning tool employing a multi-sequence optimisation algorithm. The nature of the optimisation aims to improve the overall quality of radiotherapy plans but at the same time may produce higher modulation, increasing plan complexity and challenging linear accelerator delivery capability.
Methods and materials:
Thirty patients previously treated with intensity-modulated radiotherapy (IMRT) to the prostate with or without pelvic lymph node irradiation were replanned with locally developed AP techniques for step-and-shoot IMRT (AP-IMRT) and volumetric-modulated arc therapy (AP-VMAT). Each case was also planned with VMAT using conventional inverse planning. The patient cohort was separated into two groups, those with a single primary target volume (PTV) and those with dual PTVs of differing prescription dose levels. Plan complexity was assessed using the modulation complexity score.
Results:
Plans produced with AP provided equivalent or better dose coverage to target volumes whilst effectively reducing organ at risk (OAR) doses. For IMRT plans, the use of AP resulted in a mean reduction in bladder V50Gy by 4·2 and 4·7 % (p ≤ 0·01) and V40Gy by 4·8 and 11·3 % (p < 0·01) in the single and dual dose level cohorts, respectively. For the rectum, V70Gy, V60Gy and V40Gy were all reduced in the dual dose level AP-VMAT plans by an average of 2·0, 2·7 and 7·3 % (p < 0·01), respectively. A small increase in plan complexity was observed only in dual dose level AP plans.
Findings:
The automated nature of AP led to high quality treatment plans with improvement in OAR sparing and minimised the variation in achievable dose planning metrics when compared to the conventional inverse planning approach.
Dosimetric advantages of volumetric-modulated arc therapy (VMAT) over three-dimensional conformal radiotherapy (3D-CRT) are not established in a head-on comparison of a uniform group of locally advanced carcinoma of the cervix (LACC). Therefore, we conducted a dosimetric comparison of these two techniques in LACC patients.
Materials and methods:
Computed tomography (CT) data of histologically proven de novo LACC, including Stage IIB–IIIB and earlier stages deemed inoperable, were included in this prospective observational dosimetric study. Planning was initially done by 3D-CRT technique (dose of 45–50·4 Gy @ 1·8–2 Gy/# was used in the actual treatment), followed by VMAT planning and appropriate dosimetric comparisons were done in 39 cases.
Results:
For planning target volume coverage, D95, D98 and D100 (p < 0·0001 for all parameters) and V95 and V100 (p = 0·002 and <0·0001, respectively) were significantly improved with VMAT. The conformity index (CI) was significantly better with VMAT (p = 0·03), while 3D-CRT had a significantly better homogeneity index (HI)(p = 0·003). Dose to the urinary bladder was significantly reduced with VMAT compared to 3D-CRT for V20–V50, except V10. The doses to the rectum and abdominal cavity were significantly reduced with VMAT compared to 3D-CRT plans for all parameters (V10–V50). The number of organs at risks (OARs) for which constraints were met was higher with VMAT plans than with 3D-CRT plans, with at least four out of the five OARs protected in 46·1 versus 5·1% and all constraints achieved in 15·4% versus none.
Conclusion:
We conclude that in dosimetric terms, VMAT is superior to 3D-CRT for LACC.
To study the feasibility of constant dose rate volumetric modulated arc therapy (CDR-VMAT) in radiotherapy for gallbladder cancer by comparing dosimetric parameter suggested by International Commission on Radiation Units and Measurements-83 (ICRU-83) with step and shoot intensity-modulated radiation therapy (SS IMRT).
Methods:
For this study, we selected 21 post-operative gallbladder cancer patients, which were treated with the IMRT technique from 2016 to 2019. For each patient, we generated SS IMRT plan and CDR-VMAT plan and were dosimetrically compared by parameters suggested by ICRU-83 for PTV. Homogeneity Index (HI) and Conformity Index (CI) were also calculated. For evaluation of Organ at Risk (OAR), we compared the mean doses, volume doses to the right kidney, left kidney, both kidneys combined, liver and max dose to the spinal cord. Monitor units (MUs) and treatment delivery time were also compared.
Results:
On comparing, we found that CDR-VMAT plans were highly conformed as CI and PCI (CI define by Paddick) were found more (0·98 ± 0·01 vs. 0·97 ± 0·03 and 0·86 ± 0·05 vs. 0·85 ± 0·05) than IMRT plans but not statistically significant. Better dose HI was found for IMRT plans with statistical significant difference (p < 0·001). The tumour coverage was found similar 98·24% and 97·83% for SS IMRT and CDR-VMAT, respectively. For D2%, the maximum dose to PTV was significantly lower in IMRT (p = 0·001). D50% and mean dose to PTV were also comparable to IMRT with no statistically significant difference. The OAR parameters were comparable in both the techniques. The mean doses and volume doses V10, V20 and V30 to the right kidney, left kidney and liver were also comparable with no significant difference (p > 0·05) was noted among them. However, the maximum dose to the spinal cord was significantly less in CDR-VMAT (21·1 Gy vs. 25·1Gy) than SS IMRT with p = 0·006. More MUs were associated with the CDR-VMAT technique, but shorter treatment delivery time than the IMRT technique.
Conclusions:
On dosimetric comparison of two treatment techniques, we conclude that CDR-VMAT can be a valid option in radiotherapy as it achieved highly conformed dose distribution, comparable tumour coverage and OAR sparing as IMRT technique for gallbladder cancer.
The role of the Consultant Radiographer (CR) is crossing traditional boundaries to encompass duties and responsibilities normally performed by the medical profession. Changes and streamlining of radiotherapy (RT) services result as therapeutic radiographers are taking on the responsibility of informed consent.
Purpose:
This article discusses and evaluates the legal, ethical and practical aspects of informed consent within the trust and how they have implemented the introduction of CR-led consent. It reports on the impact on the waiting times for treatment and user experience for myeloma patients receiving RT for pain relief from bone metastases.
Materials and methods:
A literature search was conducted using PubMed, CINAHL, Medline and Cochrane library using the term ‘informed consent’. The legal, ethical and practical aspects were compared to the current system and then was used to inform the development of a new pathway. Data were analysed from the department’s statistics for waiting times and the number of treatment courses.
Results and conclusions:
CR-led informed consent has streamlined the patient pathway and has improved patient care and experience.